Re: RACF question

2012-07-10 Thread Bernard Coeytaux
A common error is to have the SYS1.HELP in the LINKLIST ...

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Enabling RRS Error

2012-07-10 Thread Mike Schwab
 *Explanation:* The system logger couple data set defined by the LOGR policy
 has no free space for the type of entry you are trying to define.

Logstreams are tracked within the coupling dataset, and you have run
out of that type of entries.  Change the coupling dataset to have more
entries for that type of entry.

On Mon, Jul 9, 2012 at 11:30 PM, Jake anderson justmainfra...@gmail.com wrote:
 lizette,

 Probably I missed saying that I referred the LOOKAT ibm. LOOKAT explanation
 says :

*IXG010E*   *NO* *SPACE* *IS* *AVAILABLE* *FOR* type *ENTRIES*

 *Explanation:* The system logger couple data set defined by the LOGR policy
 has no free space for the type of entry you are trying to define.

 Here in my case I am not defining the Couple dataset so Just defining the
 Logstream to DASD.

*IXG002E*   *LOGR* *POLICY* *PROCESSING* *ENDED* *WITH* *RETCODE=*
 retcode *RSNCODE=*
  rsncode
 IXG002E LOGR POLICY PROCESSING ENDED WITH RETCODE=0008 RSNCODE=0823

 Jake

-- 
Mike A Schwab, Springfield IL USA
Where do Forest Rangers go to get away from it all?

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Enabling RRS Error

2012-07-10 Thread Vernooij, CP - SPLXM
Jake wrote Here in my case I am not defining the Couple dataset so Just
defining the Logstream to DASD.

If the Couple datasets are controlled by different departments, I am
glad I have all Sysplex constructs under my control.

I have read more problems from sites where Couple datasets, CFs and
Logstreams are controlled by different departments. Even the IBM
Logstream examples contain simple JCL to allocate Couple datasets,
update SYS1.PARMLIB etc. As if this is really as simple as this and a
site does not have policies to comply with. If I were to write those
manuals, I would say: ask the responsible department to allocate /
enlarge etc. your Couple datasets. The same applies to Logstream
structures, you (at least I) don't want application department to mess
around uncontrolled in my CFs.

Kees.


Mike Schwab mike.a.sch...@gmail.com wrote in message
news:CAJTOO5-M57=njx-sbngf+jwmxifetvv5f5otacuukgonp0p...@mail.gmail.com
...
  *Explanation:* The system logger couple data set defined by the LOGR
policy
  has no free space for the type of entry you are trying to define.
 
 Logstreams are tracked within the coupling dataset, and you have run
 out of that type of entries.  Change the coupling dataset to have more
 entries for that type of entry.
 
 On Mon, Jul 9, 2012 at 11:30 PM, Jake anderson
justmainfra...@gmail.com wrote:
  lizette,
 
  Probably I missed saying that I referred the LOOKAT ibm. LOOKAT
explanation
  says :
 
 *IXG010E*   *NO* *SPACE* *IS* *AVAILABLE* *FOR* type *ENTRIES*
 
  *Explanation:* The system logger couple data set defined by the LOGR
policy
  has no free space for the type of entry you are trying to define.
 
  Here in my case I am not defining the Couple dataset so Just
defining the
  Logstream to DASD.
 
 *IXG002E*   *LOGR* *POLICY* *PROCESSING* *ENDED* *WITH*
*RETCODE=*
  retcode *RSNCODE=*
   rsncode
  IXG002E LOGR POLICY PROCESSING ENDED WITH RETCODE=0008
RSNCODE=0823
 
  Jake
 
 -- 
 Mike A Schwab, Springfield IL USA
 Where do Forest Rangers go to get away from it all?
 
 --
 For IBM-MAIN subscribe / signoff / archive access instructions,
 send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

For information, services and offers, please visit our web site: 
http://www.klm.com. This e-mail and any attachment may contain confidential and 
privileged material intended for the addressee only. If you are not the 
addressee, you are notified that no part of the e-mail or any attachment may be 
disclosed, copied or distributed, and that any other action related to this 
e-mail or attachment is strictly prohibited, and may be unlawful. If you have 
received this e-mail by error, please notify the sender immediately by return 
e-mail, and delete this message. 

Koninklijke Luchtvaart Maatschappij NV (KLM), its subsidiaries and/or its 
employees shall not be liable for the incorrect or incomplete transmission of 
this e-mail or any attachments, nor responsible for any delay in receipt. 
Koninklijke Luchtvaart Maatschappij N.V. (also known as KLM Royal Dutch 
Airlines) is registered in Amstelveen, The Netherlands, with registered number 
33014286



--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


VTS problem

2012-07-10 Thread גדי בן אבי
Hi,

I was asked to help with a VTS problem.
I’ve never had to use VTS, so I’m not familiar with the commands.
This is the problem:
09.04.58 JOB06739  TUESDAY,   10 JUL 2012 
09.04.58 JOB06739  ICH70001I H004 LAST ACCESS AT 08:29:13 ON TUESDAY, JULY 
10, 2012
09.04.58 JOB06739  $HASP373 HRSNVLAD STARTED - INIT 6- CLASS B - SYS BOIA
09.04.58 JOB06739  IEF403I HRSNVLAD - STARTED - TIME=09.04.58
09.04.59 JOB06739  IEF233A M 
0287,V09702,,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
09.12.54 JOB06739  IEC502E K 
0287,V09702,SL,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
09.12.54 JOB06739  TMS014  IEC502E K 
0287,V09702,SL,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
09.12.54 JOB06739  IEC501A M 
0287,V09750,SL,COMP,HRSNVLAD,SAS.SASKLL,HRTM.KRANOT.SASDB.G3429V00
09.12.55 JOB06739  CBR4195I LACS RETRY POSSIBLE FOR JOB HRSNVLAD:
   IEE763I NAME= CBRLLACS CODE= 140167
   CBR4000I LACS MOUNT PERMANENT ERROR FOR DRIVE 0287.
   CBR4103I VOLUME V09750 ALREADY IN USE IN LIBRARY BIVTS.
   IEE764I END OF CBR4195I   RELATED MESSAGES

The description for CBR4103I says I have to demount the volume.
How do I do that?

Thanks

Gadi


לשימת לבך, בהתאם לנהלי החברה וזכויות החתימה בה, כל הצעה, התחייבות או מצג מטעם 
החברה, מחייבים מסמך נפרד וחתום על ידי מורשי החתימה של החברה, הנושא את לוגו 
החברה או שמה המודפס ובצירוף חותמת החברה. בהעדר מסמך כאמור (לרבות מסמך סרוק) 
המצורף להודעת דואר אלקטרוני זאת, אין לראות באמור בהודעה אלא משום טיוטה לדיון,
ואין להסתמך עליה לביצוע פעולה עסקית או משפטית כלשהי.


Please note that in accordance with Malam's signatory rights, no offer, 
agreement, concession or representation is binding on the company,
unless accompanied by a duly signed separate document (or a scanned version 
thereof), affixed with the company's seal.

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Enabling RRS Error

2012-07-10 Thread jagadishan perumal
Hi,

Allocate a new SYS1.LOGR.CDSXX(utility : IXCL1DSU) with larger
attribute,Use SETXCF COUPLE command to add the alternate CDS and change the
COUPLXX accordingly for next IPL.

Thanks

On Tue, Jul 10, 2012 at 1:22 PM, Vernooij, CP - SPLXM kees.verno...@klm.com
 wrote:

 Jake wrote Here in my case I am not defining the Couple dataset so Just
 defining the Logstream to DASD.

 If the Couple datasets are controlled by different departments, I am
 glad I have all Sysplex constructs under my control.

 I have read more problems from sites where Couple datasets, CFs and
 Logstreams are controlled by different departments. Even the IBM
 Logstream examples contain simple JCL to allocate Couple datasets,
 update SYS1.PARMLIB etc. As if this is really as simple as this and a
 site does not have policies to comply with. If I were to write those
 manuals, I would say: ask the responsible department to allocate /
 enlarge etc. your Couple datasets. The same applies to Logstream
 structures, you (at least I) don't want application department to mess
 around uncontrolled in my CFs.

 Kees.


 Mike Schwab mike.a.sch...@gmail.com wrote in message
 news:CAJTOO5-M57=njx-sbngf+jwmxifetvv5f5otacuukgonp0p...@mail.gmail.com
 ...
   *Explanation:* The system logger couple data set defined by the LOGR
 policy
   has no free space for the type of entry you are trying to define.
 
  Logstreams are tracked within the coupling dataset, and you have run
  out of that type of entries.  Change the coupling dataset to have more
  entries for that type of entry.
 
  On Mon, Jul 9, 2012 at 11:30 PM, Jake anderson
 justmainfra...@gmail.com wrote:
   lizette,
  
   Probably I missed saying that I referred the LOOKAT ibm. LOOKAT
 explanation
   says :
  
  *IXG010E*   *NO* *SPACE* *IS* *AVAILABLE* *FOR* type *ENTRIES*
  
   *Explanation:* The system logger couple data set defined by the LOGR
 policy
   has no free space for the type of entry you are trying to define.
  
   Here in my case I am not defining the Couple dataset so Just
 defining the
   Logstream to DASD.
  
  *IXG002E*   *LOGR* *POLICY* *PROCESSING* *ENDED* *WITH*
 *RETCODE=*
   retcode *RSNCODE=*
rsncode
   IXG002E LOGR POLICY PROCESSING ENDED WITH RETCODE=0008
 RSNCODE=0823
  
   Jake
 
  --
  Mike A Schwab, Springfield IL USA
  Where do Forest Rangers go to get away from it all?
 
  --
  For IBM-MAIN subscribe / signoff / archive access instructions,
  send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
 
 For information, services and offers, please visit our web site:
 http://www.klm.com. This e-mail and any attachment may contain
 confidential and privileged material intended for the addressee only. If
 you are not the addressee, you are notified that no part of the e-mail or
 any attachment may be disclosed, copied or distributed, and that any other
 action related to this e-mail or attachment is strictly prohibited, and may
 be unlawful. If you have received this e-mail by error, please notify the
 sender immediately by return e-mail, and delete this message.

 Koninklijke Luchtvaart Maatschappij NV (KLM), its subsidiaries and/or its
 employees shall not be liable for the incorrect or incomplete transmission
 of this e-mail or any attachments, nor responsible for any delay in receipt.
 Koninklijke Luchtvaart Maatschappij N.V. (also known as KLM Royal Dutch
 Airlines) is registered in Amstelveen, The Netherlands, with registered
 number 33014286
 


 --
 For IBM-MAIN subscribe / signoff / archive access instructions,
 send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN




-- 
Regards,
Jagadishan

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Enabling RRS Error

2012-07-10 Thread Barbara Nitz
The same applies to Logstream
structures, you (at least I) don't want application department to mess
around uncontrolled in my CFs.

One of the first things I have always done in a new installation was to get the 
permissions to define or change couple CDSs of any kind under the control of 
one department (mine) and one department only. If anyone else needed 
definitions, they should come to me/us and ask us. That is especially true for 
LOGR, where definitions are incremental. Should anything ever happen to the 
LOGR CDS, one wants one repository containing all (active) definitions to be 
able to rebuild the LOGR policy from one place without application failures. 

I remember quite a bit of resistance from the CICS guys when I switched them to 
the model definitions and took away their ability to define things left and 
right. 

And yes, the books are written by those that can and have done it themselves, 
without consideration for other departments/applications, much less for the 
overall picture. 

Barbara Nitz

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: VTS problem

2012-07-10 Thread Vernooij, CP - SPLXM
??? ?? ??? gad...@malam.com wrote in message
news:c11ded818b17214792b97fba28712bed150544e...@jer-email1.jer.ad.malam
.com...
 Hi,
 
 I was asked to help with a VTS problem.
 I've never had to use VTS, so I'm not familiar with the commands.
 This is the problem:
 09.04.58 JOB06739  TUESDAY,   10 JUL 2012 
 09.04.58 JOB06739  ICH70001I H004 LAST ACCESS AT 08:29:13 ON
TUESDAY, JULY 10, 2012
 09.04.58 JOB06739  $HASP373 HRSNVLAD STARTED - INIT 6- CLASS B -
SYS BOIA
 09.04.58 JOB06739  IEF403I HRSNVLAD - STARTED - TIME=09.04.58
 09.04.59 JOB06739  IEF233A M
0287,V09702,,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
 09.12.54 JOB06739  IEC502E K
0287,V09702,SL,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
 09.12.54 JOB06739  TMS014  IEC502E K
0287,V09702,SL,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
 09.12.54 JOB06739  IEC501A M
0287,V09750,SL,COMP,HRSNVLAD,SAS.SASKLL,HRTM.KRANOT.SASDB.G3429V00
 09.12.55 JOB06739  CBR4195I LACS RETRY POSSIBLE FOR JOB HRSNVLAD:
IEE763I NAME= CBRLLACS CODE= 140167
CBR4000I LACS MOUNT PERMANENT ERROR FOR DRIVE 0287.
CBR4103I VOLUME V09750 ALREADY IN USE IN LIBRARY
BIVTS.
IEE764I END OF CBR4195I   RELATED MESSAGES
 
 The description for CBR4103I says I have to demount the volume.
 How do I do that?
 
 Thanks
 
 Gadi
 

Gadi,

This means that the volume is already mounted on another unit in the
library. If the volume was mounted by another system in the Sysplex,
your z/OS would have seen that the volume was already in use and waited
for it.
Do you have other systems besides your z/OS connected to the library,
that are not connected to your z/OS? Wait for the volume to be
dismounted there of make it dismount.

Kees.


For information, services and offers, please visit our web site: 
http://www.klm.com. This e-mail and any attachment may contain confidential and 
privileged material intended for the addressee only. If you are not the 
addressee, you are notified that no part of the e-mail or any attachment may be 
disclosed, copied or distributed, and that any other action related to this 
e-mail or attachment is strictly prohibited, and may be unlawful. If you have 
received this e-mail by error, please notify the sender immediately by return 
e-mail, and delete this message. 

Koninklijke Luchtvaart Maatschappij NV (KLM), its subsidiaries and/or its 
employees shall not be liable for the incorrect or incomplete transmission of 
this e-mail or any attachments, nor responsible for any delay in receipt. 
Koninklijke Luchtvaart Maatschappij N.V. (also known as KLM Royal Dutch 
Airlines) is registered in Amstelveen, The Netherlands, with registered number 
33014286



--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: VTS problem

2012-07-10 Thread Vernooij, CP - SPLXM
The drive is online, I assume? Try the unload command: U .
Or Vary the unit Offline.

Kees.

??? ?? ??? gad...@malam.com wrote in message
news:c11ded818b17214792b97fba28712bed1503fe6...@jer-email1.jer.ad.malam
.com...
 IF I issue the LI DISPSRV, I see the volume mouted on one of the
drives.
 No other job is using the volume.
 There is only one system in the sysplex.
 
 How do I demount the volume?
 I tried restarting OAM, but that did not help.
 
 Any other idea?
 
 Gadi
 
 
 From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] On
Behalf Of Vernooij, CP - SPLXM [kees.verno...@klm.com]
 Sent: 10 July 2012 13:10
 To: IBM-MAIN@LISTSERV.UA.EDU
 Subject: Re: VTS problem
 
 ??? ?? ??? gad...@malam.com wrote in message

news:c11ded818b17214792b97fba28712bed150544e...@jer-email1.jer.ad.malam
 .com...
  Hi,
 
  I was asked to help with a VTS problem.
  I've never had to use VTS, so I'm not familiar with the commands.
  This is the problem:
  09.04.58 JOB06739  TUESDAY,   10 JUL 2012 
  09.04.58 JOB06739  ICH70001I H004 LAST ACCESS AT 08:29:13 ON
 TUESDAY, JULY 10, 2012
  09.04.58 JOB06739  $HASP373 HRSNVLAD STARTED - INIT 6- CLASS B -
 SYS BOIA
  09.04.58 JOB06739  IEF403I HRSNVLAD - STARTED - TIME=09.04.58
  09.04.59 JOB06739  IEF233A M
 0287,V09702,,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
  09.12.54 JOB06739  IEC502E K
 0287,V09702,SL,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
  09.12.54 JOB06739  TMS014  IEC502E K
 0287,V09702,SL,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
  09.12.54 JOB06739  IEC501A M
 0287,V09750,SL,COMP,HRSNVLAD,SAS.SASKLL,HRTM.KRANOT.SASDB.G3429V00
  09.12.55 JOB06739  CBR4195I LACS RETRY POSSIBLE FOR JOB HRSNVLAD:
 IEE763I NAME= CBRLLACS CODE= 140167
 CBR4000I LACS MOUNT PERMANENT ERROR FOR DRIVE
0287.
 CBR4103I VOLUME V09750 ALREADY IN USE IN LIBRARY
 BIVTS.
 IEE764I END OF CBR4195I   RELATED MESSAGES
 
  The description for CBR4103I says I have to demount the volume.
  How do I do that?
 
  Thanks
 
  Gadi
 
 
 Gadi,
 
 This means that the volume is already mounted on another unit in the
 library. If the volume was mounted by another system in the Sysplex,
 your z/OS would have seen that the volume was already in use and
waited
 for it.
 Do you have other systems besides your z/OS connected to the library,
 that are not connected to your z/OS? Wait for the volume to be
 dismounted there of make it dismount.
 
 Kees.
 
 
 For information, services and offers, please visit our web site:
http://www.klm.com. This e-mail and any attachment may contain
confidential and privileged material intended for the addressee only. If
you are not the addressee, you are notified that no part of the e-mail
or any attachment may be disclosed, copied or distributed, and that any
other action related to this e-mail or attachment is strictly
prohibited, and may be unlawful. If you have received this e-mail by
error, please notify the sender immediately by return e-mail, and delete
this message.
 
 Koninklijke Luchtvaart Maatschappij NV (KLM), its subsidiaries and/or
its employees shall not be liable for the incorrect or incomplete
transmission of this e-mail or any attachments, nor responsible for any
delay in receipt.
 Koninklijke Luchtvaart Maatschappij N.V. (also known as KLM Royal
Dutch Airlines) is registered in Amstelveen, The Netherlands, with
registered number 33014286
 
 
 
 --
 For IBM-MAIN subscribe / signoff / archive access instructions,
 send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
 
 ? ???, ? ? ? ??? ?? ??, ?? ,  ??
???  ?, ???   ? ?? ??? ? ?? ?? ?,
? ??  ? ?? ??? ?? ??? ? ?. ?  ?
(?  ) ?? ??   ???, ??? ? ?
?? ???  ? ?,
  ??  ?? ? ? ?? ?? ?.
 
 
 Please note that in accordance with Malam's signatory rights, no
offer, agreement, concession or representation is binding on the
company,
 unless accompanied by a duly signed separate document (or a scanned
version thereof), affixed with the company's seal.
 
 --
 For IBM-MAIN subscribe / signoff / archive access instructions,
 send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
 

For information, services and offers, please visit our web site: 
http://www.klm.com. This e-mail and any attachment may contain confidential and 
privileged material intended for the addressee only. If you are not the 
addressee, you are notified that no part of the e-mail or any attachment may 

Re: DB2 access and administration security

2012-07-10 Thread Chris Bowen
The original poster would be very well advised to join DB2-L and post the 
question there.  At the time of writing this does not appear to have happened.

However, for the purposes of the archives I think that it's worth recording 
here that DB2 supports controlling authorization more directly with RACF or, I 
assume, the alternative security products.

Controlling security in this way is sometimes known as external security and 
has been possible from DB2 V5, if not before. 

I have very little experience of DB2 external security myself.  Wherever I have 
worked DB2 internal security, usually using the general approach described by 
Bernd, has always been deemed sufficient.

Chris Bowen

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: VTS problem

2012-07-10 Thread גדי בן אבי
I tried that. Didn't help
I tried varying the whole library offline using the V SMS,LIB(xx),OFFLINE and 
then ONLINE. THat didn't help either.

Gadi


From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of 
Vernooij, CP - SPLXM [kees.verno...@klm.com]
Sent: 10 July 2012 14:10
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: VTS problem

The drive is online, I assume? Try the unload command: U .
Or Vary the unit Offline.

Kees.

??? ?? ??? gad...@malam.com wrote in message
news:c11ded818b17214792b97fba28712bed1503fe6...@jer-email1.jer.ad.malam
.com...
 IF I issue the LI DISPSRV, I see the volume mouted on one of the
drives.
 No other job is using the volume.
 There is only one system in the sysplex.

 How do I demount the volume?
 I tried restarting OAM, but that did not help.

 Any other idea?

 Gadi

 
 From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] On
Behalf Of Vernooij, CP - SPLXM [kees.verno...@klm.com]
 Sent: 10 July 2012 13:10
 To: IBM-MAIN@LISTSERV.UA.EDU
 Subject: Re: VTS problem

 ??? ?? ??? gad...@malam.com wrote in message

news:c11ded818b17214792b97fba28712bed150544e...@jer-email1.jer.ad.malam
 .com...
  Hi,
 
  I was asked to help with a VTS problem.
  I've never had to use VTS, so I'm not familiar with the commands.
  This is the problem:
  09.04.58 JOB06739  TUESDAY,   10 JUL 2012 
  09.04.58 JOB06739  ICH70001I H004 LAST ACCESS AT 08:29:13 ON
 TUESDAY, JULY 10, 2012
  09.04.58 JOB06739  $HASP373 HRSNVLAD STARTED - INIT 6- CLASS B -
 SYS BOIA
  09.04.58 JOB06739  IEF403I HRSNVLAD - STARTED - TIME=09.04.58
  09.04.59 JOB06739  IEF233A M
 0287,V09702,,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
  09.12.54 JOB06739  IEC502E K
 0287,V09702,SL,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
  09.12.54 JOB06739  TMS014  IEC502E K
 0287,V09702,SL,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
  09.12.54 JOB06739  IEC501A M
 0287,V09750,SL,COMP,HRSNVLAD,SAS.SASKLL,HRTM.KRANOT.SASDB.G3429V00
  09.12.55 JOB06739  CBR4195I LACS RETRY POSSIBLE FOR JOB HRSNVLAD:
 IEE763I NAME= CBRLLACS CODE= 140167
 CBR4000I LACS MOUNT PERMANENT ERROR FOR DRIVE
0287.
 CBR4103I VOLUME V09750 ALREADY IN USE IN LIBRARY
 BIVTS.
 IEE764I END OF CBR4195I   RELATED MESSAGES
 
  The description for CBR4103I says I have to demount the volume.
  How do I do that?
 
  Thanks
 
  Gadi
 

 Gadi,

 This means that the volume is already mounted on another unit in the
 library. If the volume was mounted by another system in the Sysplex,
 your z/OS would have seen that the volume was already in use and
waited
 for it.
 Do you have other systems besides your z/OS connected to the library,
 that are not connected to your z/OS? Wait for the volume to be
 dismounted there of make it dismount.

 Kees.

 
 For information, services and offers, please visit our web site:
http://www.klm.com. This e-mail and any attachment may contain
confidential and privileged material intended for the addressee only. If
you are not the addressee, you are notified that no part of the e-mail
or any attachment may be disclosed, copied or distributed, and that any
other action related to this e-mail or attachment is strictly
prohibited, and may be unlawful. If you have received this e-mail by
error, please notify the sender immediately by return e-mail, and delete
this message.

 Koninklijke Luchtvaart Maatschappij NV (KLM), its subsidiaries and/or
its employees shall not be liable for the incorrect or incomplete
transmission of this e-mail or any attachments, nor responsible for any
delay in receipt.
 Koninklijke Luchtvaart Maatschappij N.V. (also known as KLM Royal
Dutch Airlines) is registered in Amstelveen, The Netherlands, with
registered number 33014286
 


 --
 For IBM-MAIN subscribe / signoff / archive access instructions,
 send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

 ? ???, ? ? ? ??? ?? ??, ?? ,  ??
???  ?, ???   ? ?? ??? ? ?? ?? ?,
? ??  ? ?? ??? ?? ??? ? ?. ?  ?
(?  ) ?? ??   ???, ??? ? ?
?? ???  ? ?,
  ??  ?? ? ? ?? ?? ?.


 Please note that in accordance with Malam's signatory rights, no
offer, agreement, concession or representation is binding on the
company,
 unless accompanied by a duly signed separate document (or a scanned
version thereof), affixed with the company's seal.

 --
 For IBM-MAIN subscribe / signoff / archive access instructions,
 send email to lists...@listserv.ua.edu with the 

Re: VTS problem

2012-07-10 Thread גדי בן אבי
The who problem occured when a job had an I/O error while writing the virtual 
volume.
When I use the D U command, I do not see the mounted volume.
The LI REQ command gives me an error message.

This is running on a very old system (OS/390 v2.8).

Gadi

From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of 
Vernooij, CP - SPLXM [kees.verno...@klm.com]
Sent: 10 July 2012 14:54
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: VTS problem

How did the volume become mounted on the unit? Does z/OS display the
volume mounted (D U,,,,1)?

Has the volume been mounted manually, via the GUI, on the unit? Then you
can only dismount it via the GUI.
If it has not been mounted via the GUI, unfortunately you cannot
dismount it via the GUI.

Did you request details with: LI REQ,libname,LVOL,vv libname must be
the name of the composite library (if you have a grid).

Kees.

??? ?? ??? gad...@malam.com wrote in message
news:c11ded818b17214792b97fba28712bed1503fe6...@jer-email1.jer.ad.malam
.com...
 I tried that. Didn't help
 I tried varying the whole library offline using the V
SMS,LIB(xx),OFFLINE and then ONLINE. THat didn't help either.

 Gadi

 
 From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] On
Behalf Of Vernooij, CP - SPLXM [kees.verno...@klm.com]
 Sent: 10 July 2012 14:10
 To: IBM-MAIN@LISTSERV.UA.EDU
 Subject: Re: VTS problem

 The drive is online, I assume? Try the unload command: U .
 Or Vary the unit Offline.

 Kees.

 ??? ?? ??? gad...@malam.com wrote in message

news:c11ded818b17214792b97fba28712bed1503fe6...@jer-email1.jer.ad.malam
 .com...
  IF I issue the LI DISPSRV, I see the volume mouted on one of the
 drives.
  No other job is using the volume.
  There is only one system in the sysplex.
 
  How do I demount the volume?
  I tried restarting OAM, but that did not help.
 
  Any other idea?
 
  Gadi
 
  
  From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] On
 Behalf Of Vernooij, CP - SPLXM [kees.verno...@klm.com]
  Sent: 10 July 2012 13:10
  To: IBM-MAIN@LISTSERV.UA.EDU
  Subject: Re: VTS problem
 
  ??? ?? ??? gad...@malam.com wrote in message
 

news:c11ded818b17214792b97fba28712bed150544e...@jer-email1.jer.ad.malam
  .com...
   Hi,
  
   I was asked to help with a VTS problem.
   I've never had to use VTS, so I'm not familiar with the commands.
   This is the problem:
   09.04.58 JOB06739  TUESDAY,   10 JUL 2012 
   09.04.58 JOB06739  ICH70001I H004 LAST ACCESS AT 08:29:13 ON
  TUESDAY, JULY 10, 2012
   09.04.58 JOB06739  $HASP373 HRSNVLAD STARTED - INIT 6- CLASS B
-
  SYS BOIA
   09.04.58 JOB06739  IEF403I HRSNVLAD - STARTED - TIME=09.04.58
   09.04.59 JOB06739  IEF233A M
  0287,V09702,,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
   09.12.54 JOB06739  IEC502E K
  0287,V09702,SL,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
   09.12.54 JOB06739  TMS014  IEC502E K
  0287,V09702,SL,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
   09.12.54 JOB06739  IEC501A M
  0287,V09750,SL,COMP,HRSNVLAD,SAS.SASKLL,HRTM.KRANOT.SASDB.G3429V00
   09.12.55 JOB06739  CBR4195I LACS RETRY POSSIBLE FOR JOB HRSNVLAD:
  IEE763I NAME= CBRLLACS CODE= 140167
  CBR4000I LACS MOUNT PERMANENT ERROR FOR DRIVE
 0287.
  CBR4103I VOLUME V09750 ALREADY IN USE IN
LIBRARY
  BIVTS.
  IEE764I END OF CBR4195I   RELATED MESSAGES
  
   The description for CBR4103I says I have to demount the volume.
   How do I do that?
  
   Thanks
  
   Gadi
  
 
  Gadi,
 
  This means that the volume is already mounted on another unit in the
  library. If the volume was mounted by another system in the Sysplex,
  your z/OS would have seen that the volume was already in use and
 waited
  for it.
  Do you have other systems besides your z/OS connected to the
library,
  that are not connected to your z/OS? Wait for the volume to be
  dismounted there of make it dismount.
 
  Kees.
 
  
  For information, services and offers, please visit our web site:
 http://www.klm.com. This e-mail and any attachment may contain
 confidential and privileged material intended for the addressee only.
If
 you are not the addressee, you are notified that no part of the e-mail
 or any attachment may be disclosed, copied or distributed, and that
any
 other action related to this e-mail or attachment is strictly
 prohibited, and may be unlawful. If you have received this e-mail by
 error, please notify the sender immediately by return e-mail, and
delete
 this message.
 
  Koninklijke Luchtvaart Maatschappij NV (KLM), its subsidiaries
and/or
 its employees shall not be liable for the incorrect or incomplete
 transmission of this e-mail or any attachments, nor responsible for
any
 delay in receipt.
  Koninklijke Luchtvaart Maatschappij N.V. (also known as KLM Royal
 Dutch Airlines) is 

variable FIXCAT report results

2012-07-10 Thread Bonno, Tuco
environment is z/os  1.11.  am ramping up to install 1.13.

when, in z/so 1.11,  I run the smp/e  report
REPORT  MISSINGFIX ZONES(MVST100)
 FIXCAT ( IBM.COEXISTENCE.Z/OS.V1R13 )  .

report all by itself  (asking for info for ONLY ibm.coexistence.z/os.v1r13 )

the SMPPUNCH output contains

SET BDY(MVST100)
APPLY CHECK SELECT (  ……
and a long list of ptf-s appears, NONE of which is commented out.
(and the list DOES include ua59383 and ua60054 as “good to go” )
this is good.

but when I do this:

FIXCAT ( IBM.COEXISTENCE.Z/OS.V1R13
 IBM.FUNCTION.HEALTHCHECKER ) .
then i get the same laundry list of ptf-s in the SMPPUNCH output …  BUT NOW, 
the followng two ptf-s are commented out:
  ua59383, and ua60054

I have investigated those two ptf-s by reading them in the smppts dataset, as 
well as by doing a ‘query’ on their respective SMPCSI info in the smp/e dialog. 
I cannot find any reason why the  “report mssingfix fixcat” process should give 
them as “good to go” in one context, and “not good to go” in the second context.

can anyone shed any light on this in general, or in particular (as regard these 
two particular ptf-s)?  how does smp/e make such a varying determination?   
what does it have at its disposal that I , manually, do not have ?

thank you.

/s/ tuco bonno;
Graduate, College of Conflict Management;
University of SouthEast Asia;
I partied on the Ho Chi Minh Trail - tiến lên !! 


--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Sad News About Rick Fochtman

2012-07-10 Thread Graeme Gibson

Damn.. just found out about Rick F.

Knowing him only though the list, I too will miss his presence here.

Graeme

At 12:46 AM 4/07/2012, you wrote:

Rick will be missed.

Rich Sandford

DB2 Systems Database Administrator
System Engineering, Infrastructure Services
HealthPlanServices Inc.
Tampa, FL 33607-1704
(813) 289-1000 ext. 2931
(800) 237-7767 ext. 2931


--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: 'Inexperienced RBS tech operative's blunder...'

2012-07-10 Thread Scott Ford
Sam,

Sam I see this almost everyday as a ISV. A lot of misunderstands, 
misinformation, you name it.
I ave always lived if you don't know the answer just ask, i would be the first 
to help if I can.
Culturally, there are always issues, been there too..living aboard

Scott ford
www.identityforge.com

On Jul 10, 2012, at 8:29 AM, Knutson, Sam sknut...@geico.com wrote:

 I think we will see a lot of people who don't have any more details than
 we do continue to spin this to support whatever they want to say about
 the mainframe like this.
 
 http://blog.microfocus.com/avoiding-the-next-banking-crash/1577/feed 
 
 
 
 -Original Message-
 From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On
 Behalf Of Dale Miller
 Sent: Tuesday, July 03, 2012 12:23 PM
 To: IBM-MAIN@LISTSERV.UA.EDU
 Subject: Re: 'Inexperienced RBS tech operative's blunder...'
 
 Apparently, the news articles have been misread as evidenced by the
 number of comments regarding an 'operator' doing maintenance. The word
 used (by British journalists) was 'operative' which according to my
 dictionary has a first definition (as a noun) as follows: a worker,
 especially a skilled one ... , which definition most system programmers
 qualify for, although it seems the person making the mistake might not
 have qualified as 'skilled'.
 I recall the time when a two friends of mine approached me asking me to
 install an IMS application development tool. One of them said He
 probably hasn't the competence. Seeing the astonished look on my face,
 he quickly explained that he had employed the Continental English
 meaning of 'competence' which meant 'authority'.
 
 Dale Miller
 
 This email/fax message is for the sole use of the intended
 recipient(s) and may contain confidential and privileged information.
 Any unauthorized review, use, disclosure or distribution of this
 email/fax is prohibited. If you are not the intended recipient, please
 destroy all paper and electronic copies of the original message.
 
 --
 For IBM-MAIN subscribe / signoff / archive access instructions,
 send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: VTS problem

2012-07-10 Thread Vernooij, CP - SPLXM
I think you have a problem. After the I/O error the tape should have
been unmounted, but apparently has not.

Now the library and MVS have a different view on the volume and unit.
You can't use MVS to unmount the volume and I can't think of another
way.
If this is not a TS7700, can you do anything on the library interface?
If not, call IBM.

Sorry I can't help you more.
Kees.

??? ?? ??? gad...@malam.com wrote in message
news:c11ded818b17214792b97fba28712bed1503fe6...@jer-email1.jer.ad.malam
.com...
 The who problem occured when a job had an I/O error while writing the
virtual volume.
 When I use the D U command, I do not see the mounted volume.
 The LI REQ command gives me an error message.
 
 This is running on a very old system (OS/390 v2.8).
 
 Gadi
 
 From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] On
Behalf Of Vernooij, CP - SPLXM [kees.verno...@klm.com]
 Sent: 10 July 2012 14:54
 To: IBM-MAIN@LISTSERV.UA.EDU
 Subject: Re: VTS problem
 
 How did the volume become mounted on the unit? Does z/OS display the
 volume mounted (D U,,,,1)?
 
 Has the volume been mounted manually, via the GUI, on the unit? Then
you
 can only dismount it via the GUI.
 If it has not been mounted via the GUI, unfortunately you cannot
 dismount it via the GUI.
 
 Did you request details with: LI REQ,libname,LVOL,vv libname must
be
 the name of the composite library (if you have a grid).
 
 Kees.
 
 ??? ?? ??? gad...@malam.com wrote in message

news:c11ded818b17214792b97fba28712bed1503fe6...@jer-email1.jer.ad.malam
 .com...
  I tried that. Didn't help
  I tried varying the whole library offline using the V
 SMS,LIB(xx),OFFLINE and then ONLINE. THat didn't help either.
 
  Gadi
 
  
  From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] On
 Behalf Of Vernooij, CP - SPLXM [kees.verno...@klm.com]
  Sent: 10 July 2012 14:10
  To: IBM-MAIN@LISTSERV.UA.EDU
  Subject: Re: VTS problem
 
  The drive is online, I assume? Try the unload command: U .
  Or Vary the unit Offline.
 
  Kees.
 
  ??? ?? ??? gad...@malam.com wrote in message
 

news:c11ded818b17214792b97fba28712bed1503fe6...@jer-email1.jer.ad.malam
  .com...
   IF I issue the LI DISPSRV, I see the volume mouted on one of the
  drives.
   No other job is using the volume.
   There is only one system in the sysplex.
  
   How do I demount the volume?
   I tried restarting OAM, but that did not help.
  
   Any other idea?
  
   Gadi
  
   
   From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] On
  Behalf Of Vernooij, CP - SPLXM [kees.verno...@klm.com]
   Sent: 10 July 2012 13:10
   To: IBM-MAIN@LISTSERV.UA.EDU
   Subject: Re: VTS problem
  
   ??? ?? ??? gad...@malam.com wrote in message
  
 

news:c11ded818b17214792b97fba28712bed150544e...@jer-email1.jer.ad.malam
   .com...
Hi,
   
I was asked to help with a VTS problem.
I've never had to use VTS, so I'm not familiar with the
commands.
This is the problem:
09.04.58 JOB06739  TUESDAY,   10 JUL 2012 
09.04.58 JOB06739  ICH70001I H004 LAST ACCESS AT 08:29:13 ON
   TUESDAY, JULY 10, 2012
09.04.58 JOB06739  $HASP373 HRSNVLAD STARTED - INIT 6- CLASS
B
 -
   SYS BOIA
09.04.58 JOB06739  IEF403I HRSNVLAD - STARTED - TIME=09.04.58
09.04.59 JOB06739  IEF233A M
   0287,V09702,,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
09.12.54 JOB06739  IEC502E K
   0287,V09702,SL,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
09.12.54 JOB06739  TMS014  IEC502E K
   0287,V09702,SL,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
09.12.54 JOB06739  IEC501A M
   0287,V09750,SL,COMP,HRSNVLAD,SAS.SASKLL,HRTM.KRANOT.SASDB.G3429V00
09.12.55 JOB06739  CBR4195I LACS RETRY POSSIBLE FOR JOB
HRSNVLAD:
   IEE763I NAME= CBRLLACS CODE= 140167
   CBR4000I LACS MOUNT PERMANENT ERROR FOR DRIVE
  0287.
   CBR4103I VOLUME V09750 ALREADY IN USE IN
 LIBRARY
   BIVTS.
   IEE764I END OF CBR4195I   RELATED MESSAGES
   
The description for CBR4103I says I have to demount the volume.
How do I do that?
   
Thanks
   
Gadi
   
  
   Gadi,
  
   This means that the volume is already mounted on another unit in
the
   library. If the volume was mounted by another system in the
Sysplex,
   your z/OS would have seen that the volume was already in use and
  waited
   for it.
   Do you have other systems besides your z/OS connected to the
 library,
   that are not connected to your z/OS? Wait for the volume to be
   dismounted there of make it dismount.
  
   Kees.
  
   
   For information, services and offers, please visit our web site:
  http://www.klm.com. This e-mail and any attachment may contain
  confidential and privileged material intended for the addressee
only.
 If
  you are not the addressee, you are notified that no 

Re: variable FIXCAT report results

2012-07-10 Thread Kurt Quackenbush
Using UA60054 as the example, it is applicable to both fix categories 
(IBM.Function.HealthChecker and IBM.Coexistence.z/OS.V1R13), so it will 
show up twice in the SELECT list of the SMPPUNCH output, once for each 
category.  The second occurrence will be commented out so as not to 
produce an SMP/E error if you submit the generated APPLY step.


Kurt Quackenbush -- IBM, SMP/E Development

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


PTF: UA63842 - verifying it is working

2012-07-10 Thread McKown, John
I just installed PTF UA63842 on my sandbox system. I also got ICSF running. The 
messages from the CSF started task are:

CSFO0230 CKDSN(TSSTV.CSF.CKDS)
CSFO0230 PKDSN(TSSTV.CSF.PKDS)
CSFO0230 COMPAT(NO)
CSFO0230 SSM(YES)
CSFO0230 KEYAUTH(NO) /* WAS YES */
CSFO0230 CHECKAUTH(NO)
CSFO0230 TRACEENTRY(599)
CSFO0220 TRACEENTRY VALUE NOT IN RANGE.
CSFO0230 USERPARM(USERPARM)
CSFO0230 COMPENC(DES)
CSFO0212 COMPENC KEYWORD NO LONGER SUPPORTED.
CSFO0230 REASONCODES(ICSF)
CSFO0230 PKDSCACHE(64)
CSFO0212 PKDSCACHE KEYWORD NO LONGER SUPPORTED.
CSFO0166 DEFAULT CICS WAIT LIST WILL BE USED.
CSFM607I A CKDS KEY STORE POLICY IS NOT DEFINED.
CSFM607I A PKDS KEY STORE POLICY IS NOT DEFINED.
CSFM610I GRANULAR KEYLABEL ACCESS CONTROL IS DISABLED.
CSFM611I XCSFKEY EXPORT CONTROL FOR AES IS DISABLED.
CSFM611I XCSFKEY EXPORT CONTROL FOR DES IS DISABLED.
CSFM612I PKA KEY EXTENSIONS CONTROL IS DISABLED.
CSFM101E PKA KEY DATA SET, TSSTV.CSF.PKDS IS NOT INITIALIZED.
CSFM100E CRYPTOGRAPHIC KEY DATA SET, TSSTV.CSF.CKDS IS NOT INITIALIZED.
CSFM507I CRYPTOGRAPHY - THERE ARE NO CRYPTOGRAPHIC COPROCESSORS ONLINE.
CSFM508I CRYPTOGRAPHY - THERE ARE NO CRYPTOGRAPHIC ACCELERATORS ONLINE.
*CSFM122I PKA SERVICES WERE NOT ENABLED DURING ICSF INITIALIZATION.
CSFM001I ICSF INITIALIZATION COMPLETE
CSFM126I CRYPTOGRAPHY - FULL CPU-BASED SERVICES ARE AVAILABLE.

I think this last message means that ICSF is using the CPACF facilities on the 
CPU. True?

I then recycled the SSHD daemon. How do I know that SSHD is actually using the 
CPACF instead of the older method for its encryption?. Is there any message 
anywhere that I could look at? I see some messages in /var/log/auth, but 
nothing in depth.

--  
John McKown 
Systems Engineer IV
IT

Administrative Services Group

HealthMarkets(r)

9151 Boulevard 26 * N. Richland Hills * TX 76010
(817) 255-3225 phone * 
john.mck...@healthmarkets.com * www.HealthMarkets.com

Confidentiality Notice: This e-mail message may contain confidential or 
proprietary information. If you are not the intended recipient, please contact 
the sender by reply e-mail and destroy all copies of the original message. 
HealthMarkets(r) is the brand name for products underwritten and issued by the 
insurance subsidiaries of HealthMarkets, Inc. -The Chesapeake Life Insurance 
Company(r), Mid-West National Life Insurance Company of TennesseeSM and The 
MEGA Life and Health Insurance Company.SM

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: VTS problem

2012-07-10 Thread Gibney, Dave
Vary the drive offline with the FORCE option.  

 -Original Message-
 From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU]
 On Behalf Of Vernooij, CP - SPLXM
 Sent: Tuesday, July 10, 2012 6:02 AM
 To: IBM-MAIN@LISTSERV.UA.EDU
 Subject: Re: VTS problem
 
 I think you have a problem. After the I/O error the tape should have
 been unmounted, but apparently has not.
 
 Now the library and MVS have a different view on the volume and unit.
 You can't use MVS to unmount the volume and I can't think of another
 way.
 If this is not a TS7700, can you do anything on the library interface?
 If not, call IBM.
 
 Sorry I can't help you more.
 Kees.
 
 ??? ?? ??? gad...@malam.com wrote in message
 news:C11DED818B17214792B97FBA28712BED1503FE6C3D@JER-
 EMAIL1.jer.ad.malam
 .com...
  The who problem occured when a job had an I/O error while writing the
 virtual volume.
  When I use the D U command, I do not see the mounted volume.
  The LI REQ command gives me an error message.
 
  This is running on a very old system (OS/390 v2.8).
 
  Gadi
  
  From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] On
 Behalf Of Vernooij, CP - SPLXM [kees.verno...@klm.com]
  Sent: 10 July 2012 14:54
  To: IBM-MAIN@LISTSERV.UA.EDU
  Subject: Re: VTS problem
 
  How did the volume become mounted on the unit? Does z/OS display the
  volume mounted (D U,,,,1)?
 
  Has the volume been mounted manually, via the GUI, on the unit? Then
 you
  can only dismount it via the GUI.
  If it has not been mounted via the GUI, unfortunately you cannot
  dismount it via the GUI.
 
  Did you request details with: LI REQ,libname,LVOL,vv libname must
 be
  the name of the composite library (if you have a grid).
 
  Kees.
 
  ??? ?? ??? gad...@malam.com wrote in message
 
 news:C11DED818B17214792B97FBA28712BED1503FE6C3C@JER-
 EMAIL1.jer.ad.malam
  .com...
   I tried that. Didn't help
   I tried varying the whole library offline using the V
  SMS,LIB(xx),OFFLINE and then ONLINE. THat didn't help either.
  
   Gadi
  
   
   From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] On
  Behalf Of Vernooij, CP - SPLXM [kees.verno...@klm.com]
   Sent: 10 July 2012 14:10
   To: IBM-MAIN@LISTSERV.UA.EDU
   Subject: Re: VTS problem
  
   The drive is online, I assume? Try the unload command: U .
   Or Vary the unit Offline.
  
   Kees.
  
   ??? ?? ??? gad...@malam.com wrote in message
  
 
 news:C11DED818B17214792B97FBA28712BED1503FE6C3A@JER-
 EMAIL1.jer.ad.malam
   .com...
IF I issue the LI DISPSRV, I see the volume mouted on one of the
   drives.
No other job is using the volume.
There is only one system in the sysplex.
   
How do I demount the volume?
I tried restarting OAM, but that did not help.
   
Any other idea?
   
Gadi
   

From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] On
   Behalf Of Vernooij, CP - SPLXM [kees.verno...@klm.com]
Sent: 10 July 2012 13:10
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: VTS problem
   
??? ?? ??? gad...@malam.com wrote in message
   
  
 
 news:C11DED818B17214792B97FBA28712BED150544E9BB@JER-
 EMAIL1.jer.ad.malam
.com...
 Hi,

 I was asked to help with a VTS problem.
 I've never had to use VTS, so I'm not familiar with the
 commands.
 This is the problem:
 09.04.58 JOB06739  TUESDAY,   10 JUL 2012 
 09.04.58 JOB06739  ICH70001I H004 LAST ACCESS AT 08:29:13
 ON
TUESDAY, JULY 10, 2012
 09.04.58 JOB06739  $HASP373 HRSNVLAD STARTED - INIT 6-
 CLASS
 B
  -
SYS BOIA
 09.04.58 JOB06739  IEF403I HRSNVLAD - STARTED - TIME=09.04.58
 09.04.59 JOB06739  IEF233A M
0287,V09702,,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
 09.12.54 JOB06739  IEC502E K
0287,V09702,SL,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
 09.12.54 JOB06739  TMS014  IEC502E K
0287,V09702,SL,HRSNVLAD,SAS,HRTM.KRANOT.SASDB.G3429V00
 09.12.54 JOB06739  IEC501A M
   
 0287,V09750,SL,COMP,HRSNVLAD,SAS.SASKLL,HRTM.KRANOT.SASDB.G3429V00
 09.12.55 JOB06739  CBR4195I LACS RETRY POSSIBLE FOR JOB
 HRSNVLAD:
IEE763I NAME= CBRLLACS CODE= 140167
CBR4000I LACS MOUNT PERMANENT ERROR FOR
 DRIVE
   0287.
CBR4103I VOLUME V09750 ALREADY IN USE IN
  LIBRARY
BIVTS.
IEE764I END OF CBR4195I   RELATED MESSAGES

 The description for CBR4103I says I have to demount the volume.
 How do I do that?

 Thanks

 Gadi

 with the message: INFO IBM-MAIN

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: VTS problem

2012-07-10 Thread Vernooij, CP - SPLXM
McKown, John john.mck...@healthmarkets.com wrote in message
news:a6b9336cdb62bb46b9f8708e686a7ea0115baa1...@nrhmms8p02.uicnrh.dom.
..
  -Original Message-
  From: IBM Mainframe Discussion List 
  [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Vernooij, CP - SPLXM
  Sent: Tuesday, July 10, 2012 1:54 PM
  To: IBM-MAIN@LISTSERV.UA.EDU
  Subject: Re: VTS problem
  
  I doubt this will help. As far as MVS is concerned, there is no tape
  mounted, so it will not issue a Rewind / Unload command.
  
  Kees.
 
 Hum, makes me wonder what would happen if you issued an MVS MOUNT
command of a different volume on the same tape device name?
 
 -- 
 John McKown 

I think the library will refuse it, because it has a tape mounted on the
unit.

Gadi, could you try this?

Kees.


For information, services and offers, please visit our web site: 
http://www.klm.com. This e-mail and any attachment may contain confidential and 
privileged material intended for the addressee only. If you are not the 
addressee, you are notified that no part of the e-mail or any attachment may be 
disclosed, copied or distributed, and that any other action related to this 
e-mail or attachment is strictly prohibited, and may be unlawful. If you have 
received this e-mail by error, please notify the sender immediately by return 
e-mail, and delete this message. 

Koninklijke Luchtvaart Maatschappij NV (KLM), its subsidiaries and/or its 
employees shall not be liable for the incorrect or incomplete transmission of 
this e-mail or any attachments, nor responsible for any delay in receipt. 
Koninklijke Luchtvaart Maatschappij N.V. (also known as KLM Royal Dutch 
Airlines) is registered in Amstelveen, The Netherlands, with registered number 
33014286



--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Sad News About Rick Fochtman

2012-07-10 Thread Ed Finnell
One of the other list members sent me an obituary reference. It's a  
difficult web page to navigate(for me) and blew out my browser a couple times.  
Anyway, it's pretty much RYO expecting tweets and FB friends.
 
In Naperville, IL it's at:
http://illinois.obituaries.funeral.com/2012/07/06/richard-a-fochtman-jr-june
-29-2012-view-details-beidelman-kunsch-funeral-home-crematory-downtown-chape
l/




In a message dated 7/10/2012 7:50:02 A.M. Central Daylight Time,  
gra...@ase.com.au writes:

Knowing  him only though the list, I too will miss his presence  here

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Secure Encryption Keys vs Protected Keys

2012-07-10 Thread Mary Anne Matyaz
This makes you the keymaster, right?

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: RACF question

2012-07-10 Thread Walt Farrell
On Sat, 7 Jul 2012 16:49:13 -0400, Scott Ford scott_j_f...@yahoo.com wrote:

Joel,

Hers the exact error:


11.51.03 STC00472  CSV025I PROGRAM CONTROLLED MODULE ADDUSER  NOT ACCESSED, USE
11.51.03 STC00472 IEF196I CSV025I PROGRAM CONTROLLED MODULE ADDUSER  NOT ACCES
11.51.03 STC00472  IEF196I UNAUTHORIZED
11.51.03 STC00472  CSV028I ABEND306-30  JOBNAME=RACF  STEPNAME=RACF
11.51.03 STC00472  IEF196I CSV028I ABEND306-30  JOBNAME=RACF  STEPNAME=RACF


That should indicate that they have not given the RACF subsystem address space 
access to whatever PROGRAM profile they have defined to control use of ADDUSER. 
And that they are not running the subsystem TRUSTED, which is always a good 
idea for recovery and availability purposes.

Note that they should not use program control for ADDUSER, as there are 
adequate other controls in place, so they may have an overly broad PROGRAM 
generic, such as PROGRAM *, with an overly restrictive access list. It should 
have UACC(READ) or at a minimum ID(*) ACCESS(READ). That should be true, imho, 
even if they have hardened their system.

And anyone who decides to harden a system certainly should have kept 
documentation about what they did, and why, with a good rationale for all the 
protections they've applied.

-- 
Walt

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Sad News About Rick Fochtman

2012-07-10 Thread Scott Ford
Ed,
Thank you, he will be missed, life is short

Scott ford
www.identityforge.com

On Jul 10, 2012, at 3:33 PM, Ed Finnell efinnel...@aol.com wrote:

 One of the other list members sent me an obituary reference. It's a  
 difficult web page to navigate(for me) and blew out my browser a couple 
 times.  
 Anyway, it's pretty much RYO expecting tweets and FB friends.
 
 In Naperville, IL it's at:
 http://illinois.obituaries.funeral.com/2012/07/06/richard-a-fochtman-jr-june
 -29-2012-view-details-beidelman-kunsch-funeral-home-crematory-downtown-chape
 l/
 
 
 
 
 In a message dated 7/10/2012 7:50:02 A.M. Central Daylight Time,  
 gra...@ase.com.au writes:
 
 Knowing  him only though the list, I too will miss his presence  here
 
 --
 For IBM-MAIN subscribe / signoff / archive access instructions,
 send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Sad News About Rick Fochtman

2012-07-10 Thread Mike Schwab
I managed to find the Funeral home page.  Looks like a mainframe
computer diagram.  Too blurry for me to read.

http://www.beidelmankunschfh.com/obituaries/Richard-Fochtman/#/PhotosVideos/525bc8eb-6f6f-47d0-9b43-b0c2fb376fe3/b3c86b78-7d68-4448-89c2-d82e3535a2b3

On Tue, Jul 10, 2012 at 2:33 PM, Ed Finnell efinnel...@aol.com wrote:
 One of the other list members sent me an obituary reference. It's a
 difficult web page to navigate(for me) and blew out my browser a couple times.
 Anyway, it's pretty much RYO expecting tweets and FB friends.

 In Naperville, IL it's at:
 http://illinois.obituaries.funeral.com/2012/07/06/richard-a-fochtman-jr-june
 -29-2012-view-details-beidelman-kunsch-funeral-home-crematory-downtown-chape
 l/




 In a message dated 7/10/2012 7:50:02 A.M. Central Daylight Time,
 gra...@ase.com.au writes:

 Knowing  him only though the list, I too will miss his presence  here

 --
 For IBM-MAIN subscribe / signoff / archive access instructions,
 send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN



-- 
Mike A Schwab, Springfield IL USA
Where do Forest Rangers go to get away from it all?

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Sad News About Rick Fochtman

2012-07-10 Thread Ed Finnell
Sorry, spur of the moment. Don't see a way to zoom or 'full page' the  
pictures. Maybe when the storm blows over I'll do something more  rational. 
 
 
In a message dated 7/10/2012 3:35:27 P.M. Central Daylight Time,  
mike.a.sch...@gmail.com writes:

Looks  like a mainframe
computer diagram.  Too blurry for me to  read.



--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Moving JES2 spool volumes

2012-07-10 Thread Edward Jaffe

n 7/10/2012 3:02 PM, Skip Robinson wrote:

We need to move an R13 JES2 MAS onto new spool volumes. R13 introduced the
$MSPL command to migrate/move spool dynamically. We have not used $MSPL.
Any advice?


Make sure all of your IBM and ISV products can support remapped JES2 SPOOL 
addresses (MTTRs and MQTRs). If they use only standard, JES2-provided facilities 
to read SPOOL then all should be fine.


--
Edward E Jaffe
Phoenix Software International, Inc
831 Parkview Drive North
El Segundo, CA 90245
310-338-0400 x318
edja...@phoenixsoftware.com
http://www.phoenixsoftware.com/

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


JFCB field question

2012-07-10 Thread Paul Schuster
Hi:

Is the field JFCBEXTL ever non-zero?  The comments in the JFCB dsect say it is 
the 


LENGTH OF BLOCK OF EXTRA VOLUME SERIAL NUMBERS
(BEYOND FIVE) 
 

but it seems no matter how many volumes I code for a JCL or dynamica allocation 
disk data set the field is always zero.  

Thank you.

Paul

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Moving JES2 spool volumes

2012-07-10 Thread Lizette Koehler

We need to move an R13 JES2 MAS onto new spool volumes. R13 introduced the 
$MSPL command to migrate/move spool dynamically. We have not used $MSPL. 
Any advice? 

.
.
JO.Skip Robinson


Funny you should ask.  IBM Systems Mag has the following article.

http://ibmsystemsmag.com/mainframe/administrator/migration/spool_migration_part2/


Lizette

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Secure Encryption Keys vs Protected Keys

2012-07-10 Thread Shane Ginnane
Shane, just curious - why?

I will defer to Gregs subsequent response which pretty-well hit it on the head.

I spin through my mail first thing in the morning. And for us in Aus that 
usually means after threads have had time to ripen somewhat overnight.
Often that means run off track, but in this case it meant further descent 
into the (terminology) mire.

Just too heavy for this little black duck prior to the initial caffeine hit of 
the day  ... ;-)

Shane ...

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Moving JES2 spool volumes

2012-07-10 Thread Warren Brown
Did you get married?  If so, best wishes





From: Lizette Koehler stars...@mindspring.com
To: IBM-MAIN@LISTSERV.UA.EDU
Sent: Tue, July 10, 2012 8:04:49 PM
Subject: Re: Moving JES2 spool volumes


We need to move an R13 JES2 MAS onto new spool volumes. R13 introduced the 
$MSPL command to migrate/move spool dynamically. We have not used $MSPL. 
Any advice? 

.
.
JO.Skip Robinson


Funny you should ask.  IBM Systems Mag has the following article.

http://ibmsystemsmag.com/mainframe/administrator/migration/spool_migration_part2/



Lizette

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


SMPE receive Error

2012-07-10 Thread mf db
Dear All,

I am in a process of receiving a DB2 related FMID into Global Zone but
during Receive  one of a Dataset is not getting allocated due to space
constraint.


*SMPOUT :*

GIM35302E ** SMPTLIB SYS1.DB2.V10.HDDA211.F1 WAS NOT ALLOCATED ON VOLUME
DT3WK1
 BECAUSE ERROR CODE 4714 WAS ISSUED BY DYNAMIC
ALLOCATION.
GIM54701E ** ALLOCATION FAILED FOR SMPTLIB - IKJ56245I DATA
SET
 SYS1.DB2.V10.HDDA211.F1 NOT ALLOCATED, NOT ENOUGH SPACE
ON
 VOLUMES+.

I have created another volume DT3WK2 so that  SYS1.DB2.V10.HDDA211.F1 gets
allocated but thats not happening.

*JCL* :

//SMP  EXEC PGM=GIMSMP,PARM='DATE=U',REGION=0M
//SMPCSI   DD  DSN=SMPE.DB2.GLOBAL.CSI,DISP=SHR
//SMPHOLD  DD  DUMMY
//SMPPTFIN DD  DSN=IBMUSER.HDDA211.SMPMCS,DISP=OLD
//SMPCNTL  DD  *
SET BDY(GLOBAL).  /* Set to GLOBAL zone   */
RECEIVE SELECT(
   HDDA211
   )
   .  /* RECEIVE this FMID*/
/*

I am at : *SMP/E 35.34*
 *Z/OS : 1.12*

Is it possible to direct a dynamic allocation to the next available free
volumes during Receive ? Folks If i have missed something during
Receive then please direct me.

Peter

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: SMPE receive Error

2012-07-10 Thread Lizette Koehler
 
 Dear All,
 
 I am in a process of receiving a DB2 related FMID into Global Zone but
during Receive
 one of a Dataset is not getting allocated due to space constraint.
 
 
 *SMPOUT :*
 
 GIM35302E ** SMPTLIB SYS1.DB2.V10.HDDA211.F1 WAS NOT ALLOCATED ON VOLUME
 DT3WK1
  BECAUSE ERROR CODE 4714 WAS ISSUED BY DYNAMIC ALLOCATION.
 GIM54701E ** ALLOCATION FAILED FOR SMPTLIB - IKJ56245I DATA SET
  SYS1.DB2.V10.HDDA211.F1 NOT ALLOCATED, NOT ENOUGH SPACE ON
  VOLUMES+.
 
 I have created another volume DT3WK2 so that  SYS1.DB2.V10.HDDA211.F1 gets
 allocated but thats not happening.
 
 *JCL* :
 
 //SMP  EXEC PGM=GIMSMP,PARM='DATE=U',REGION=0M
 //SMPCSI   DD  DSN=SMPE.DB2.GLOBAL.CSI,DISP=SHR
 //SMPHOLD  DD  DUMMY
 //SMPPTFIN DD  DSN=IBMUSER.HDDA211.SMPMCS,DISP=OLD
 //SMPCNTL  DD  *
 SET BDY(GLOBAL).  /* Set to GLOBAL zone   */
 RECEIVE SELECT(
HDDA211
)
.  /* RECEIVE this FMID*/
 /*
 
 I am at : *SMP/E 35.34*
  *Z/OS : 1.12*
 
 Is it possible to direct a dynamic allocation to the next available free
 volumes during Receive ? Folks If i have missed something during
 Receive then please direct me.
 
 Peter

A couple of questions.  Are these NONSMS or SMS Managed volumes?  Why do you
use a SYS1 hlq for an SMPTLIB dataset?

SYS1. Typically goes into the master catalog and is not a great place to put
these types of files.  A usercat is more acceptable in many cases.

What is your UCLIN for the SMPTLIB look like?

Lizette

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: SMPE receive Error

2012-07-10 Thread mf db
Hi Lizette/All,

This are basically NON SMS managed volumes.


*My SMPTLIB looks :*

CSI QUERY - SMPTLIB DDDEF
ENTRY
 ===



  To return to the previous panel, enter END
.


  Entry Type:  DDDEF   Zone Name:
GLOBAL
  Entry Name:  SMPTLIB Zone Type:
GLOBAL




  DSPREFIX:
SYS1.ZOS


  VOLUME:
DT3WK1
  UNIT:
3390
  SPACE :PRIM:   SECOND:
DIR:
  PROTECT:
WAITFORDSN:
  DATACLAS:
MGMTCLAS:
  STORCLAS:  DSNTYPE
:



Peter


On Wed, Jul 11, 2012 at 8:54 AM, Lizette Koehler stars...@mindspring.comwrote:

 
  Dear All,
 
  I am in a process of receiving a DB2 related FMID into Global Zone but
 during Receive
  one of a Dataset is not getting allocated due to space constraint.
 
 
  *SMPOUT :*
 
  GIM35302E ** SMPTLIB SYS1.DB2.V10.HDDA211.F1 WAS NOT ALLOCATED ON VOLUME
  DT3WK1
   BECAUSE ERROR CODE 4714 WAS ISSUED BY DYNAMIC ALLOCATION.
  GIM54701E ** ALLOCATION FAILED FOR SMPTLIB - IKJ56245I DATA SET
   SYS1.DB2.V10.HDDA211.F1 NOT ALLOCATED, NOT ENOUGH SPACE ON
   VOLUMES+.
 
  I have created another volume DT3WK2 so that  SYS1.DB2.V10.HDDA211.F1
 gets
  allocated but thats not happening.
 
  *JCL* :
 
  //SMP  EXEC PGM=GIMSMP,PARM='DATE=U',REGION=0M
  //SMPCSI   DD  DSN=SMPE.DB2.GLOBAL.CSI,DISP=SHR
  //SMPHOLD  DD  DUMMY
  //SMPPTFIN DD  DSN=IBMUSER.HDDA211.SMPMCS,DISP=OLD
  //SMPCNTL  DD  *
  SET BDY(GLOBAL).  /* Set to GLOBAL zone   */
  RECEIVE SELECT(
 HDDA211
 )
 .  /* RECEIVE this FMID*/
  /*
 
  I am at : *SMP/E 35.34*
   *Z/OS : 1.12*
 
  Is it possible to direct a dynamic allocation to the next available free
  volumes during Receive ? Folks If i have missed something during
  Receive then please direct me.
 
  Peter

 A couple of questions.  Are these NONSMS or SMS Managed volumes?  Why do
 you
 use a SYS1 hlq for an SMPTLIB dataset?

 SYS1. Typically goes into the master catalog and is not a great place to
 put
 these types of files.  A usercat is more acceptable in many cases.

 What is your UCLIN for the SMPTLIB look like?

 Lizette

 --
 For IBM-MAIN subscribe / signoff / archive access instructions,
 send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: SMPE receive Error

2012-07-10 Thread Ed Finnell
IIRC 4714 says userid does not have update for DASDVOL.DT3WK1 profile?  
maybe there's ICH msg in log.
 
 
In a message dated 7/10/2012 10:24:52 P.M. Central Daylight Time,  
stars...@mindspring.com writes:

BECAUSE  ERROR CODE 4714 WAS ISSUED BY DYNAMIC  ALLOCATION.


--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN