Re: Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator

2012-07-05 Thread Jiri Pospisil
Request System discussion list(ARSList) [mailto:arslist@ARSLIST.ORG] On Behalf Of Tauf Chowdhury Sent: 04 July 2012 18:15 To: arslist@ARSLIST.ORG Subject: Re: Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator ** Jiri, Are you on a load

Re: Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator

2012-07-05 Thread Melissa reed
the other day, just not what specifically. Thanks! Melissa From: Lou lrguar...@yahoo.com To: arslist@ARSLIST.ORG, Date: 07/03/2012 06:13 PM Subject:Re: Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator Sent

Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator

2012-07-05 Thread John Baker
Melissa, Mid Tier does not cluster (an interesting point given the other thread concerning performance), so you must have sticky sessions enabled. With the F5, you need a feature called 'OneConnect' enabled. If I recall, the default F5 sticky sessions means reuse HTTP connections (at the

Re: Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator

2012-07-04 Thread ITSM.Support
(ARSList) [mailto:arslist@ARSLIST.ORG] On Behalf Of Jiri Pospisil Sent: Tuesday, July 03, 2012 10:20 PM To: arslist@ARSLIST.ORG Subject: Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator ** Hi all, I was wondering

Re: Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator

2012-07-04 Thread Tauf Chowdhury
Jiri, Are you on a load balanced environment? I've seen cases where the plugin entry for ARDBC needs to be configured for the FQDN of the local server name instead of the load balancer name in the ar.conf. On Tue, Jul 3, 2012 at 12:49 PM, Jiri Pospisil jiri.pospi...@lchclearnet.com wrote: **

Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator

2012-07-03 Thread Jiri Pospisil
Hi all, I was wondering if anybody has ever seen the following behaviour. About a week ago, our users started getting error “ ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator” when opening AR System Customizable Home Page on mid-tier with

Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator

2012-07-03 Thread John Baker
Hello It's a bug in the Mid Tier. The stack trace is trying to convert a string, I assume read from the request, to a number. The string is empty and hence the parse fails, leading to the exception (which should be caught and handled, but isn't). I think you'll need to collect a Fiddler

Re: Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator

2012-07-03 Thread Jiri Pospisil
Sent: 03 July 2012 21:00 To: arslist@ARSLIST.ORG Subject: Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator Hello It's a bug in the Mid Tier. The stack trace is trying to convert a string, I assume read from the request

Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator

2012-07-03 Thread John Baker
Sorry, I missed that part. I'm surprised that Fiddler changes the way the Javascript runs - you may want to think about using wireshark to get a packet trace, but that's quite low level stuff. Either way, it's a bug and it's not your fault :)

Re: Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator

2012-07-03 Thread Lou
) [mailto:arslist@ARSLIST.ORG] On Behalf Of John Baker Sent: 03 July 2012 21:00 To: arslist@ARSLIST.ORG Subject: Mid-Tier error ARERR [9350] Network protocol/data error when performing data operation. Please contact administrator Hello It's a bug in the Mid Tier. The stack trace is trying to convert