On Tuesday 06 July 2010 08:53:54 pm Thierry wrote:
1.The two main routers connected to the upstreams (both
get full internet table from them) will be Route
Reflectors. We will create a cluster on these two
routers.
If you can, try and have other routers running as your route
On 22/06/2010, at 10:42 PM, Gert Doering wrote:
On Tue, Jun 22, 2010 at 08:03:22AM -0400, Jared Mauch wrote:
The bug is CSCth43783. The control plane comes up but the data plane is not
forwarded properly. The mls appears to be populated as drop.
Once it's resolved we are going to ask for
Guys,
This time i lost rip section only, other than that whole config was there. I
am lost, not getting anything out of it.
What could be the issue, cisco partners not giving any solution.
Regards,
Raheel
On Mon, Jul 12, 2010 at 11:09 AM, David Hughes da...@hughes.com.au wrote:
On
On 12/07/10 11:02, Raheel Muhammad wrote:
Guys,
This time i lost rip section only, other than that whole config was there. I
am lost, not getting anything out of it.
What could be the issue, cisco partners not giving any solution.
You never answered (several) questions people asked you:
Hi all
I am having a small testup, where I am playing with BGP update timers
I have one thing, which is driving me insane -
CISCO2851 nr 1 Running BGP (local AS number 65412)
250 loopback interfaces
distributed into BGP
|
Cisco 7609 nr 1 Running BGP (local AS number 65500)
interface
Hi all
Can someone give me a hint. I'm having problems with eompls on an vss setup.
I have central site with the vss and to external sites.
One site with a WS-SUP720-3BXL , and another site with a WS-SUP720-3B.
From the site with WS-SUP720-3B I have tengig uplink to the vss, and from the
Site
All,
We have three E1 voice circuits on a 2821 - two from the same provider
on on E1 0/0/0 and E1 0/0/1, and a third from a different provider on a
E1 0/1/0 - a separate VIC.
After fixing a broken fan on the router, the third E1 is experiencing
slip seconds. The other two are clean, and I
Hi Jay,
The action 'pass' on the class-default is different from 'inspect' as it
does not perform stateful inspection and, therefore, there is no state
table for return traffic to be compared against.
As such, even though traffic was initiated from inside, the router
thinks the return traffic is
Can you show us show ip route x.x.x.x, show ip cef x.x.x.x, and show mpls
l2 vc vc-id detail from each end of the non-working VC. x.x.x.x should be VC
endpoints.
-Ben
On Jul 12, 2010, at 6:52 AM, Arne Larsen / Region Nordjylland wrote:
Hi all
Can someone give me a hint. I'm having
Peter Hicks wrote:
All,
We have three E1 voice circuits on a 2821 - two from the same provider
on on E1 0/0/0 and E1 0/0/1, and a third from a different provider on a
E1 0/1/0 - a separate VIC.
After fixing a broken fan on the router, the third E1 is experiencing
slip seconds. The
According to your show run all interfaces on the router are in
shutdown state, so nothing is going to work. One you have interfaces up,
you also need to have working routes at each end to the IP address of
the pseudowire endpoint at the other end.
--
Vincent C. Jones
Networking Unlimited, Inc.
Peter Hicks wrote:
All,
We have three E1 voice circuits on a 2821 - two from the same provider
on on E1 0/0/0 and E1 0/0/1, and a third from a different provider on
a
E1 0/1/0 - a separate VIC.
After fixing a broken fan on the router, the third E1 is experiencing
slip seconds. The
Sorry to take so long for the the update. I can't believe the interfaces were
shutdown... but over the weekend I retried it and had success in getting the
setup exactly how we wanted, which was dot1q over the T1.
HQ-Switch#show run
vlan 1998
!
!
interface FastEthernet1/0/1
switchport trunk
Hi,
The other day we had a weird crash, with no crashlog written.
System returned to ROM by power on at 11:14:29 UTC Thu Jun 17 2010 (SP by
watchdog NMI at PC 0x40A09538, address 0x0)
System restarted at 15:58:57 BST Thu Jul 1 2010
System image file is
Quick question to all. When I configure the nssa area it removes the static
default route I setup on my remote router. I configured a static route of
0.0.0.0 0.0.0.0 x.x.x.x on the remote router and it has a metric of 1 and a
cost of 0. When the nssa commands are put in place on the head end
Hi,
I'm wondering if there is an elegant way to do per user filtering for remote
access accounts on a pix 506E running
6.3.(x)? I know i can create seperate groups with different access defined,
however, this is not a solution that
would scale neatly. Though it may be my only option. Thanks.
Hi Dalton,
Using RADIUS to assign either group policy or a direct ACL is supported on
newer versions of the ASA software (ie. 7.x 8.x). I don't think you can
upgrade a 506E beyond 6.x though. You could always try these options and see if
they work on 506E 6.3.x
Hi all,
I am contemplating upgrading a 7600 with redundant SUP720-3B's from
12.2(33)SRD1 to SRD4 using ISSU (which is something I haven't played with
before).
I've read the doco and it seems reasonably straightforward.
The question I have is can I run the upgrade remotely on a VTY session
18 matches