Bob,
Similar situation applies to EN 300 440
Electromagnetic compatibility and Radio spectrum
Matters (ERM); Short range devices; Radio equipment to
be used in the 1 GHz to 40 GHz frequency range. 440-2
is harmonized but reference to 440-1 which is not
harmonized.
What I did for my customers
Bob, the -1 standard will not be published in the OJ since it is considered
to be a reference standard similar to the same status as the EN 61000-4
series. Since the test suite is contained in the -2 harmonized standard, you
no longer need to use a Notified Body.
Richard Woods
Bob,
My understanding is that EN 300330-1 is a basic standard; EN 300330-2 is the
calling standard. Similar to other basic standards, only the calling
standards need to be announced (e.g., EN 50082-1 needs to be announced, not
EN 61000-4-3).
Regards,
Don Umbdenstock
Sensormatic
--