TEMPEST regulations

2003-05-09 Thread Alexandru Guidea
Dear colleagues, I am looking to procure an UK (or NATO) TEMPEST standard/regulation -- JSP 480. Any help in finding a source for this doc will be greatly appreciated. Whether some confidentiality restrictions exist, they can be resolved by our library, as it has similar docs. Thanks, Guidea

reinforced insulation - EN60950

2003-05-08 Thread Alexandru Guidea
+ FuseTransorb(15V) equivalent to Reinforced Insulation? 2. Does the transorb have to comply with a specific EN safety standard (like one applicable to Y caps)? Thanks, Alexandru Guidea CAE Inc. Canada Basic Insulation | | ELV

reinforced insulation - EN60950

2003-05-07 Thread Alexandru Guidea
with a specific EN safety standard (like one applicable to Y caps)? Thanks, Alexandru Guidea CAE Inc. Canada Basic Insulation | | ELV||---FUSE--SELV (??) | T

RE: Wire Colors

2003-06-03 Thread Alexandru Guidea
Suggest to replace your European power cord (L/N/GND) with a North-American one (L/L/GND). North-American power outlets don't allow to reverse L and N supply wires of an apparatus to avoid exposing the user to some 120VAC. Guess it's due to some appliances equipped with 2 wire power cords,

Russian regulations

2003-07-31 Thread Alexandru Guidea
similarity with European Directives and standards. Any help greatly appreciated. Alexandru Guidea CAE Inc. Canada This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your

surplus ferrite tiles

2003-08-22 Thread Alexandru Guidea
the job. RANTEC FT-100; TDK IB015; TDK X131. Thanks, Alexandru Guidea CAE Inc. This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail

RE: Insertion loss of an injection probe

2003-08-21 Thread Alexandru Guidea
conducted disturbance. Another useful parameter is the Transfer Impedance of the probe, which can be measured, or calculated function of the Insertion Loss. Hope it helps. Alexandru Guidea. From: Luke Turnbull [mailto:luke.turnb...@trw.com] Sent: Wednesday, August 20, 2003 3:05 AM To: emc-p

RE: stun guns on aircraft

2002-05-07 Thread Alexandru Guidea
Making an analogy with the EMC world, it is interesting how America, which allows its citizens to bear firearms (for self-protection, of course), does not enforce regulations on immunity. As for Sam's reflections The reason we're the prime superpower is because the world knows we will use it

EMC regulations in Norway

1998-08-13 Thread Alexandru Guidea
. Thanks, Alexandru Guidea CAE Electronics Ltd. Montreal, Canada From: Keith Armstrong karmstr...@iee.org To: CAE Montreal.smtp(rehel...@mmm.com) List-Post: emc-pstc@listserv.ieee.org Date: 7/29/98 12:04pm Subject:Product recall on EMC non-compliance rehel...@mmm.com wrote: I

looking for ferrite tile absorbers

1998-08-24 Thread Alexandru Guidea
Few months ago, someone posted a message about used ferrite tile absorber panels for sale. If still available, please send me a message at gui...@cae.ca. Thanks, Alexandru Guidea CAE Electronics Montreal, Canada - This message is coming from the emc-pstc discussion list. To cancel your

Need 220VAC Power Strips for Racks -Reply

1998-12-11 Thread Alexandru Guidea
Ray, We purchase what you are looking for from Olson Electronics, London, UK, Tel. 0181 8852884, Fax. 0181 885 2496. Good luck! Alexandru Guidea CAE Electronics rkes...@monitoringtech.com 12/08/98 07:53pm Hello to all, I am in need of finding an EMI, surge protected, etc., etc. power strip

battery back-up systems -- CE Mark

1998-03-30 Thread Alexandru Guidea
part of the equipment. Is there any concern about the type of batteries employed in these systems? Are any national environmental regulations limiting the choice? Thanks. Alexandru Guidea CAE Electronics Ltd. Montreal, Canada

Shipping and CE-marking installations

1999-09-20 Thread Alexandru Guidea
will be taken into service following the issuance of the DoC and CE marking. How can the equipment be shipped to an EU country without risking annoyance to the customs? Has any legal basis the Declaration of Incorporation? Thanks for your help. Alexandru Guidea - This message is coming from the emc

Shipping and CE-marking installations

1999-09-16 Thread Alexandru Guidea
the Declaration of Incorporation? Thanks for your help. Alexandru Guidea - This message is coming from the emc-pstc discussion list. To cancel your subscription, send mail to majord...@ieee.org with the single line: unsubscribe emc-pstc (without the quotes). For help, send mail to ed.pr

RE: Immunity Requirements for Australia -Reply

1999-09-15 Thread Alexandru Guidea
We use AS/NZS 4252.1:1994, which is a copy of EN 50082-1. Don't know whether there is any equivalent of EN50082-2. Alexandru Guidea. sparaci...@andovercontrols.com 09/15/99 09:48am Hello Charlie, I don't believe Australia has any immunity requirements at this time. They do require

HAR cables

1999-07-20 Thread Alexandru Guidea
) but tested at 2000V or 3000V, depending on the manufacturer. They all call CENELEC Doc. HD21, IEC 227, and VDE 0281. How some of these cables can be used for equipment designated for Europe when other standards (60950) require 3000V ? Thanks, Alexandru Guidea CAE Electronics Montreal, Canada

RE: CE MARKING A SYSTEM

2002-04-30 Thread Alexandru Guidea
certain immunity tests. We also had to buy industrial-grade equipment for parts of our installation where commercial one would have done the job. If you need more info, we can continue this discussion via private email. Alexandru Guidea CAE Inc. -Original Message- From: Gordon,Ian

subcontracted parts - compliance with EN's

2002-09-25 Thread Alexandru Guidea
of such a paper in North-America? As we don't control their production (parts, quality, etc,) what's the documentation we shall request to ensure all production units are compliant? What's the industry/your practice in this case? Alexandru Guidea CAE Inc. Montreal, CANADA

RE: E-field probe for immunity testing

2002-11-13 Thread Alexandru Guidea
on batteries and it has a fiber link to a remote indicator powered from the mains. Alexandru Guidea CAE Inc. I am seeking sources for an E-field probe for radiated immunity testing other than Holaday and Amplifier Research. Any suggestions? Richard Woods Sensormatic Electronics Tyco International

RE: EU DoC

2002-11-08 Thread Alexandru Guidea
. However, my message is true when at least company B is located elsewhere in the world. Alexandru Guidea. -Original Message- From: Chris Allen [mailto:chris_al...@eur.3com.com] Sent: Thursday, November 07, 2002 2:34 AM To: richwo...@tycoint.com Cc: emc-p...@majordomo.ieee.org Subject: Re

RE: EU DoC

2002-11-06 Thread Alexandru Guidea
company A all necessary proof of compliance with the relevant standards. 2. Company B qualifies the product and prepares supporting documentation. Company B will do QA, audits and inspections at company A to ensure consistency of all products with the test sample(s). Alexandru Guidea CAE Inc

Conclusions: subcontracted parts - compliance with EN's

2002-09-27 Thread Alexandru Guidea
notice). Alexandru Guidea CAE Inc. Montreal, CANADA Our company purchases power distribution equipment designed per our specs. This equipment is not put on the market, but integrated in our products, and does safety/EMC functions(EMI filtering, protection, emergency stop) among other things

CE marking of equipment for military facilities

2002-03-04 Thread Alexandru Guidea
would be CE marked to LVD, Machinery, and EMC Directives. Thanks, Alexandru Guidea CAE Inc. Montreal, Canada --- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http

job posting

2002-02-28 Thread Alexandru Guidea
Dear colleagues, Hope a job posting for a compliance engineer position will not do too much harm to the scope of this group. For those close to or willing to move to Montreal, Canada, please see the summary below. Alexandru Guidea CAE Inc. Montreal, Canada Here is a summary of the required

Re: [PSES] Surge Testing 3 phase Equipment

2015-02-17 Thread Alexandru Guidea
minutes to complete the test, assuming the sequence of the tests is switched automatically and no operator intervention will add delays. For compliance testing, there is no need for other coupling modes. Alexandru Guidea CAE Inc. From: Kunde, Brian [mailto:brian_ku...@lecotc.com] Sent: February-17

Re: [PSES] RS FSP Spectrum Analyzer

2015-02-17 Thread Alexandru Guidea
of their main competitor and always had excellent support. Alexandru Guidea CAE Inc. Alexandru G. -Original Message- From: Grace Lin [mailto:graceli...@gmail.com] Sent: February-16-15 4:02 PM To: EMC-PSTC@LISTSERV.IEEE.ORG Subject: [PSES] RS FSP Spectrum Analyzer Dear Members, Is anyone familiar

Re: [PSES] Radio in class A product

2015-05-28 Thread Alexandru Guidea
328. Obviously, a Notified Body for the RTTE directive can be consulted for an unequivocal certification plan. Alexandru Guidea CAE Inc. From: Paasche, Dieter [mailto:dieter.paas...@christiedigital.com] Sent: 27 May 2015 16:29 To: EMC-PSTC@LISTSERV.IEEE.ORGmailto:EMC-PSTC@LISTSERV.IEEE.ORG