Re: EN61000-3-2 / EN61000-3-3 (Again)

2001-01-04 Thread Craig Hensley
Thanks to everyone who responded to my questions regarding EN61000-3-2 / 3-3. This was a great help as the responses were very clear and consistent. At least for now, I have a much better understanding of these standards and their scope. Craig Hensley Iomega Corp. Craig Hensley 01/03/01

EN61000-3-2 / EN61000-3-3 (Again)

2001-01-03 Thread Craig Hensley
dilemma on the DoC's. Is it reasonable to claim compliance via non-applicability? I apologize for the conversational tone of this e-mail, but I am interested in any other views and opinions. Best Regards for 2001, Craig Hensley Iomega Corp. Roy, UT

RE: UL94-5VA B

2000-12-21 Thread Craig Hensley
Since I deal solely with ITE-based standards I can't answer your question with any certainty. Perhaps there is someone else out there with the details? Craig Hensley Iomega Corp. Gary McInturff gary.mcintu...@worldwidepackets.com 12/21/00 12:15PM Then I assume there are times when

Re: UL94-5VA B

2000-12-21 Thread Craig Hensley
or 94-5VB flammability rating is considered to meet the Class 5V material flammability requirement. This same interpretation should hold true for material classified as 5V per EN69050. Happy Holidays, Craig Hensley Iomega Corp. Roy, UT William D'Orazio dora...@cae.ca 12/21/00 08:00AM Gents

Re: Power Cord Question

2000-05-26 Thread Craig Hensley
other than the US style. This power supply has a standard IEC 320 C8 inlet on one end. We just include the appropriate (certified) power cord for the region along with this supply. The cord has the plug on one end and an IEC 320 C7 appliance connector on the other. Craig Hensley Iomega Corp

Energy Star Thanks

1996-05-29 Thread CRAIG HENSLEY
. For me (and I'm sure all others will agree), It has quickly become an invaluable resource tool. Craig Hensley Iomega Corp. Roy, Utah (801) 778-4135

Energy Star Program??

1996-05-28 Thread CRAIG HENSLEY
broad knowledge base of participants on the PSTC forum I felt this was a good place to query for information. THANKS!! Craig Hensley Compliance Engineer Iomega Corp. Roy, Utah (801) 778-4135

Environmental Seminars??

1996-05-16 Thread CRAIG HENSLEY
to get a better understanding of the upcoming requirements. Any information would be greatly appreciated. Craig Hensley Compliance Engineer Iomega (removable data storage devices) Roy, Utah (801) 778-4135

Requirements for South Africa

1997-01-08 Thread CRAIG HENSLEY
requirements for either EMI and Safety? Any information provided would be greatly appreciated. Craig Hensley Iomega Corp. Roy, UT

Safety in Turkey, Israel, South Africa. -Reply

1997-05-20 Thread CRAIG HENSLEY
. For more detailed information I suggest you contact Mr. Ben Kruger at the South African Bureau of Standards. His number is 27-12-4286677 ext. 6677. He was very helpful in answering my questions. Craig Hensley Iomega Corp. Roy, Utah (801) 778-4135 Rich Nute ri...@sdd.hp.com 05/20/97 09:30am

Signal Words -Reply

1997-09-02 Thread CRAIG HENSLEY
hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. Based on these definitions, CAUTION, would be used to warn against practices which could result in product or property damage. Hope this helps some, Craig Hensley

Load Tray Requirements?

1997-09-17 Thread CRAIG HENSLEY
hazard, or is it more related to Machinery Directive-type standards? Thanks in advance for any information. Craig Hensley Compliance Engineer Iomega Corp. Roy, Utah

RE: Re:RE: Taiwan EMI Requirements -Reply

1997-12-16 Thread CRAIG HENSLEY
of. Craig Hensley Iomega Corp. DouglasScott sdoug...@ecrm.com 12/16/97 09:05am Yes. The BCIQ accepted lab I am using is: Integrity Design Test Services, Inc. 37-7 Ayer Road Littleton, MA 01460 (978) 486-0432 (978) 486 0592 fax. My contact there is Eric Wilbur. Regards, Scott sdoug

RE: Taiwan EMI Requirements -Reply

1997-12-16 Thread CRAIG HENSLEY
may not be as simple as it sounds, this is just a simplified explanation. Craig Hensley Iomega Corporation Terry J. Meck tjm...@accusort.com 12/16/97 09:40am Douglas: The information I have gleaned indicates CISPR 22 Emissions tests are required. Are there any immunity tests required? In other

Electronic Documentation

1998-10-30 Thread CRAIG HENSLEY
in the FCC or European regulations on this. Our products consist of removable, high-capacity computer disk drives (Zip drive). Thanks for any and all inputs. Craig Hensley Iomega Corp. Roy, UT - This message is coming from the emc-pstc discussion list. To cancel your subscription, send mail

Questions on Plug Adapters -Reply

1998-12-04 Thread CRAIG HENSLEY
original believe that we should be providing the right (certified) cord-set with each unit shipped and not an adapter kludge. Since we are a worldwide company we have to learn to better deal with the implications of supporting the many different plug styles. Happy Holidays to All, Craig Hensley Iomega