It makes me a bit proud, that a German can teach an American in English
;-))) But By the way, I haven't also heard this word before. I had looked it
up in a translation dictionary. To accept with bruxism is a saying in
Germany, if you have to accept something as a fact, but you don't like to do
Hi all,
one of my customers wants to replace his 9672 G5 by a z800. He is running
zOS 1.5. I will install the PSP ptfs for the z800 before. Are there any
other pitfalls regarding 31Bit to 64Bit or should everything work 1:1 with
the current configuration. Additionally to the zOS he runs a DB2 V7
this we have done. The customer is in a difficult economical situation and
the z9BC would have been three times as expensive as the used z800 which is
already ordered. You can believe me that we have discussed all variations
with the customer and there was no way to sell a z9, which also IBM had
Hi experts,
I have a customer who has currently a 9672-R36 with 2 SAPs. It is used as an
SAP database server. The machine runs normally at approx. 40 to 50% CPU and
a channel usage (ESS-F20 with 8 Escon) of approx. 40%. We want to replace
this machine by a used z800-002. In the LSPR tables the
I had forgotten one thing to mention. At peak times the machine runs at 80
to 90% CPU.
- Original Message -
From: Pohlen (Mailinglist) [EMAIL PROTECTED]
To: zOS Forum IBM-MAIN@BAMA.UA.EDU
Sent: Wednesday, August 16, 2006 1:59 PM
Subject: z800-002 compared to 9672-R36 with 2 SAPs
Hi
to 9672-R36 with 2 SAPs
On Wed, 2006-08-16 at 13:59 +0200, Pohlen (Mailinglist) wrote:
I have a customer who has currently a 9672-R36 with 2 SAPs. It is used
as an
SAP database server. The machine runs normally at approx. 40 to 50% CPU
and
a channel usage (ESS-F20 with 8 Escon) of approx. 40
we are in discussion with the customer to replace his environment by a
zseries with ficon attached dasd and perhaps 3592 at end of this year, but
at the moment he needs a quick and relatively cheap solution for his current
problem.
regards
Franz Josef
- Original Message -
From: Bruce
Hi listers,
I have a customer who backs up a data amount of about 500 GB with 2 Jobs
each day on a 2-drives-3590 with DSS. Because of data growth, he has now
problems with his batch window. His 3590 (A50/B11) is connected to his R36
by one escon channel. During the backup the channel is
[EMAIL PROTECTED]
Newsgroups: bit.listserv.ibm-main
To: IBM-MAIN@BAMA.UA.EDU
Sent: Wednesday, January 18, 2006 8:30 PM
Subject: Re: [IBM-MAIN] Two silly questions about USS or OMVS on Z/OS
In a recent note, Pohlen Mailinglist said:
Date: Wed, 18 Jan 2006 16:34:06 +0100
in omvs you
Johnny,
there is port name called otelnet in file /etc/services which points to the
port of the uss telnet. Of course either the otelnetd daemon or the
configured inetd must be running. The port of otelnet must be different from
the normal telnet port for tso. You must also have defined an omvs
just as every unix, go into omvs and enter ps -ef ! grep xxx. Pay attention,
the sign behind the ps -ef is an exclamation mark.
- Original Message -
From: Johnny Luo [EMAIL PROTECTED]
Newsgroups: bit.listserv.ibm-main
To: IBM-MAIN@BAMA.UA.EDU
Sent: Wednesday, January 18, 2006 3:26 PM
, January 18, 2006 4:13 PM
Subject: Re: [IBM-MAIN] Two silly questions about USS or OMVS on Z/OS
In a recent note, Pohlen Mailinglist said:
Date: Wed, 18 Jan 2006 15:50:47 +0100
just as every unix, go into omvs and enter ps -ef ! grep xxx. Pay
attention,
My experience
questions about USS or OMVS on Z/OS
In a recent note, Pohlen Mailinglist said:
Date: Wed, 18 Jan 2006 15:50:47 +0100
just as every unix, go into omvs and enter ps -ef ! grep xxx. Pay
attention,
My experience is that the options for ps are not the same for every
unix.
Is ps
Isn't it possible to group these datasets by an own hlq, which will not
change, so that you can react on this or those special hlq(s) in your ACS
routines? Then you could change your datasets as often as you want to do,
without having to change your ACS routines frequently.
Franz Josef Pohlen
you
should look to Peer to Peer VTS
Mike WoodRMM Development
On Wed, 12 Oct 2005 16:05:15 +0200, Pohlen Mailinglist fjpohlen-
[EMAIL PROTECTED] wrote:
Hi Mike,
I know the DITTO function, but it cannot be used in case of disaster
recovery, because you normally will not have an actual
For your new VTS/3584 configuration, be aware, that you need a third box
beside VTS and 3584 called 3953, which hosts the FICON/ESCON interfaces, the
library manager and the controller(s) for the 3592 tape drives.
For your disaster recovery, it is important, that the vts at Sungard is
standalone
It is chapter 4 in my user guide (zos 1.4), number 4.9 Submitting FTP
requests in batch.
- Original Message -
From: Pohlen Mailinglist [EMAIL PROTECTED]
To: IBM Mainframe Discussion List IBM-MAIN@BAMA.UA.EDU
Sent: Wednesday, October 12, 2005 4:11 PM
Subject: Re: FTP continuation
In the User Guide there is a chapter in FTP subcommands
4.. A blank followed by a plus sign ( + ) at the end of an FTP subcommand
line is used as a continuation indicator for all FTP subcommands except the
QUOTE subcommand. When the continuation indicator is encountered at the end
of an FTP
Hi Mike,
I know the DITTO function, but it cannot be used in case of disaster
recovery, because you normally will not have an actual export tape of the
vts when there is a disaster situation. In my opinion vts-export can only be
used for planned actions e. g. merging logical volumes from one vts
Hi listers,
I'm trying to apply the ptf UQ80253 on my DB2 V7 and get the following
message in link-edit.
z/OS V1 R5 BINDER 16:57:13 TUESDAY SEPTEMBER 6, 2005
BATCH EMULATOR JOB(MV16APPD) STEP(SMPAPPLY) PGM= HEWLH096
IEW2278I B352 INVOCATION PARAMETERS -
10:38:20 +0200, Pohlen Mailinglist wrote:
IEW2456E 9207 SYMBOL §§STERM8 UNRESOLVED. MEMBER COULD NOT BE INCLUDED
FROM THBE INCLUDED FROM THE DESIGNATED CALL LIBRARY.
Can anyone put me in the right direction to solve the problem?
APAR II13151 (5) + (6) ?
Norbert Friemel
You can, but you have to pay attention, that all the information in the
BEGINVTAM part is obeyed. Alternatively you can obey the whole ip profile.
There will be some errors (port already defined, device already defined and
so on) but you cannot forget informations.
Hope this helps
Franz Josef
I haven't followed this discussion from the beginning, but for FTPing a
ADRDSSU file, you only have to terse this file with trsmain (lrecl 1024,
FB), binary transfer (on FTP-PUT use SITE RECFM=FB LRECL=1024 BLKSIZE=6144),
unpack and restore, READY !!! If you don't have TRSMAIN, download it from
Hello Bruce,
the devices become all online, only at start of the devices in tcpip it
hangs in status starting. Therefore I get no error sense code, with which
I could perhaps diagnose the problem. The chpid is dedicated to the lpar
and, as I said, on os390 everything works fine. So there cannot
24 matches