Re: JES2 Queue Times / SMF30 Data Zones

2010-06-20 Thread Ed Gould
From: Tom Wasik wa...@us.ibm.com To: IBM-MAIN@bama.ua.edu Sent: Fri, June 18, 2010 12:23:05 PM Subject: Re: JES2 Queue Times / SMF30 Data Zones Let me explain what each time means/comes from and perhaps that will help answer your questions: SMF30RST - The comment

Re: JES2 Queue Times / SMF30 Data Zones

2010-06-19 Thread Thierry Deleris
Hello, First a big thank to Jan, Ravi and Tom for their lights on this subject ! I will try to make a diagram of the different times involved in the SMF30 records before initiation time to complete my analyses thanks to your informations. Another question about these following lines from Tom

Re: JES2 Queue Times / SMF30 Data Zones

2010-06-19 Thread Scott Barry
On Sat, 19 Jun 2010 04:07:23 -0500, Thierry Deleris thierry.deleris_s...@i-bp.banquepopulaire.fr wrote: Hello, First a big thank to Jan, Ravi and Tom for their lights on this subject ! I will try to make a diagram of the different times involved in the SMF30 records before initiation time to

Re: JES2 Queue Times / SMF30 Data Zones

2010-06-18 Thread Tom Wasik
Let me explain what each time means/comes from and perhaps that will help answer your questions: SMF30RST - The comment in the IFASMFR3 macro states TIME, IN HUNDREDTHS OF A SECOND READER RECOGNIZED THE JOB CARD FOR THIS JOB. This is precisely correct. It is when JES2 input processing sees the

Re: JES2 Queue Times / SMF30 Data Zones

2010-06-17 Thread Ravi Kumar
Thierry, Here I try giving you answer with my test example... 1) I ran a test job (as below) J E S 2 J O B L O G -- S Y S T E M 1 X 0 1 -- N O D 05.25.48 JOB00596 THURSDAY, 17

Re: JES2 Queue Times / SMF30 Data Zones

2010-06-16 Thread Jan MOEYERSONS
On Tue, 15 Jun 2010 09:51:58 -0500, Thierry Deleris thierry.deleris_s...@i- BP.BANQUEPOPULAIRE.FR wrote: JES2 Queues before Processing (Conversion Execution) thanks to SMF30-5 records. Please be aware that I am not at all familiar with SMF records. 11.08.15 JOB94550 TUESDAY, 01 JUN 2010

Re: JES2 Queue Times / SMF30 Data Zones

2010-06-16 Thread Thierry Deleris
Hello, Thanks for your reply ! As mentionned there is no time spent in Duplicate State (Computed in SMF30HQT). There is no Dataset or other ressources waiting time too... And finally, our Initiators are not WLM-Managed... Have another idea of investigations ? Best regards,

JES2 Queue Times / SMF30 Data Zones

2010-06-15 Thread Thierry Deleris
Hello, I'm looking after some informations about the time a Job could spend in some JES2 Queues before Processing (Conversion Execution) thanks to SMF30-5 records. Example with a Job (Data from SMF30-5) : - Timestamp Time (SMF30RST) : 11:02:06 - Start Time (SMF30SIT) : 11:09:19 == So we