Funny? It's a shame! Why run websphere (just an example) on a mainframe if
even ibm runs on windows?
ITschak
בתאריך 21 ביול 2015 16:59, George Rodriguez
george.rodrig...@palmbeachschools.org כתב:
Probably... That's funny!
*George Rodriguez*
*Specialist II - IT Solutions*
*IT Enterprise
z/OS 1.11 provided the ECVTXTSW field as a programming interface. The
documentation for the service pointed to by that field is in the
commentary for that field (and is only there).
Peter Relson
z/OS Core Technology Design
--
On 21 July 2015 at 02:13, glen herrmannsfeldt g...@ugcs.caltech.edu wrote:
OK, I forgot that the Usenet gateway doesn't work anymore.
Imminent death of the net predicted!
I am wondering what software one needs for a 3705 to connect up ordinary
ASCII terminals.
Typically just EP. But it
On Tue, 21 Jul 2015 10:31:50 -0500, David Evans wrote:
This dataset can be deleted using ISMF. It allows you to delete a dataset
that has the same name as a cataloged dataset. No rename required.
The obstacle isn't the catalog; the obstacle is the ENQ.
-- gil
On Tue, Jul 21, 2015 at 5:52 AM, David Crayford dcrayf...@gmail.com wrote:
On 20/07/2015 9:37 PM, John McKown wrote:
Thanks for the pointer. This is a on my own project which has been put
on the back burner. I'm fighting a hardware upgrade issue at home right
now. I think the SATA
I stand corrected... It's actually sad, because the Mainframe not the
Window Server would take the hit!
*George Rodriguez*
*Specialist II - IT Solutions*
*IT Enterprise Applications*
*PX - 47652*
*(561) 357-7652 (office)*
*(954) 415-7586 (mobile)*
*School District of Palm Beach County*
*3348
For a company that prides itself on its flagship Operating System offering 6
nines of availability, they should be ashamed.
Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of George Rodriguez
Sent: Tuesday, July 21, 2015 10:54 AM
To:
The *OLD* way is to get the address of the format4.dscb of the data
set (from iehlist)
Use amaspzap with the syslib of format4.dscb (and dcb=keylen=44)
the zap statement with something like :
... I am forgetting what the first statement is but I am thinking
cchhr 8 hex address you got from
In 55ad3edd.3020...@aim.com, on 07/20/2015
at 12:33 PM, Paul Gilmartin
000433f07816-dmarc-requ...@listserv.ua.edu said:
What's in a name?
Wasting lots of time looking things up in the wrong manuals and coding
to the wrong rules. BTDT,GTS
--
Shmuel (Seymour J.) Metz, SysProg and
This dataset can be deleted using ISMF. It allows you to delete a dataset
that has the same name as a cataloged dataset. No rename required.
David Evans, CISSP
Systems Programmer
Technical Services
Trustmark National Bank
Office: (601) 208-7930
From: Lizette Koehler
On 2015-07-21, at 07:20, Burrell, C. Todd (CDC/OCOO/OCIO/ITSO) (CTR) wrote:
It's probably a Windows 2003 server :-).
They're back; and their headers don't say:
531 $ curl -D /dev/fd/3http://www.redbooks.ibm.com/ 31 /dev/null
0 00 00 0 0 0 --:--:--
You might need to show us the code for your dataclass routine but before that
can you confirm that you used ISMF to:
translate the routine without error into a working SCDS dataset after
updating the source;
validate the routine
test the routine with the same DSN;
activate
After doing the freevol, the SDSP contains the high value record and 6
records for another dataset. Viewing a recent DCOLLECT and searching
for the leading part of the dataset name, we found 2 migrated datasets
with time stamps over the last 2 months and 4 backups of the dataset
over the last 3
OK, I modified a SMS dataclass to specify datasetype extented and extended
addressability. When I run the job to create the linear cluster I still get the
IDC3014I CATALOG ERROR IDC3009I **
VSAM CATALOG RETURN CODE IS 140 - REASON CODE IS
IDC3009I
On Tue, 21 Jul 2015 11:35:40 -0400, Tony Harminc wrote:
On 21 July 2015 at 02:13, glen herrmannsfeldt wrote:
OK, I forgot that the Usenet gateway doesn't work anymore.
Imminent death of the net predicted!
I am wondering what software one needs for a 3705 to connect up ordinary
ASCII
g...@ugcs.caltech.edu (glen herrmannsfeldt) writes:
OK, I forgot that the Usenet gateway doesn't work anymore.
I am wondering what software one needs for a 3705 to connect
up ordinary ASCII terminals.
For example, what would be needed to use TSO or Wylbur on
ASCII terminals? I know this is
On Tue, 21 Jul 2015 11:40:28 -0500, Paul Gilmartin paulgboul...@aim.com wrote:
On Tue, 21 Jul 2015 10:31:50 -0500, David Evans wrote:
This dataset can be deleted using ISMF. It allows you to delete a dataset
that has the same name as a cataloged dataset. No rename required.
The obstacle
It is my understanding that this is the purpose of $MSPL, but I did not have
much luck (probably due to a procedural error(?) on my part).
I just went through the process in reverse. Migrating Mod 3 spool to Mod 9. I
issued a $PSPL prior to the $MSPL. When the $MSPL was issued, very little
Bo That's what I was afraid of. :(
Anne D. Crabtree
System Programmer
WV Office of Technology Data Center
1900 Kanawha Blvd East
Bldg 6, Room B-110
Charleston, WV 25305
(304)957-8292
(304)558-1441 fax
-Original Message-
From: IBM Mainframe Discussion List
On Tue, Jul 21, 2015 at 1:13 AM, glen herrmannsfeldt g...@ugcs.caltech.edu
wrote:
OK, I forgot that the Usenet gateway doesn't work anymore.
I am wondering what software one needs for a 3705 to connect
up ordinary ASCII terminals.
For example, what would be needed to use TSO or Wylbur on
In JES2, I have 11 SPOOL volumes but the last two I added were mod 9's,
whereas, the others are mod 3's. I did not mean to put the SPOOL volumes on
mod 9's. I have issued the drain ($PSPOOLA) to drain that volume but there is
obviously a lot of stuff on it and I don't know how long it will
On Tue, Jul 21, 2015 at 12:45 PM, John McKown
john.archie.mck...@gmail.com wrote:
Versus what other distribution? RH was one of the first available. When I
first tried, and failed, there was mainly only Slackware. I couldn't get
that installed on my XT.
Ahhh... Good ol' Slackware. I tried that
Are these DCOLLECT entries current?
If you have review and/or fileaid, get the mig DSN from the SDSP and browse
the MCDS to get the true dsn.
THEN :
HDEL 'dataset name'
Delete SDSP
HRECOVER 'dataset name'DSN (from backup)
HTH,
snip
After doing the freevol, the SDSP contains the high
In 20150721061350.bb5994874...@lara.ugcs.caltech.edu, on 07/20/2015
at 11:13 PM, glen herrmannsfeldt g...@ugcs.caltech.edu said:
OK, I forgot that the Usenet gateway doesn't work anymore.
I am wondering what software one needs for a 3705 to connect up
ordinary ASCII terminals.
NTO. Why?
--
To bring up APL\360 on MVT 21.8F, they had to fix the Hercules drivers
for IBM 1052-7 and IBM 2741.
http://wotho.ethz.ch/mvt4apl-2.00/
On Tue, Jul 21, 2015 at 11:57 AM, Paul Gilmartin
000433f07816-dmarc-requ...@listserv.ua.edu wrote:
On Tue, 21 Jul 2015 11:35:40 -0400, Tony Harminc wrote:
The stranded data set has a create date time in the name from 10 months ago.
Does not show B or M records in DCOLLECT.
Several current datasets have create date time from last week to 2 months ago.
Shows several B and M records in DCOLLECT over last 3 months.
So the HDEL and HRECOVER on the
On 2015-07-21, at 11:08, Walt Farrell wrote:
On Tue, 21 Jul 2015 11:40:28 -0500, Paul Gilmartin wrote:
On Tue, 21 Jul 2015 10:31:50 -0500, David Evans wrote:
This dataset can be deleted using ISMF. It allows you to delete a dataset
that has the same name as a cataloged dataset. No
Shmuel Metz , Seymour J. shmuel+ibm-m...@patriot.net wrote:
In 20150721061350.bb5994874...@lara.ugcs.caltech.edu, on 07/20/2015
(snip, I wrote)
OK, I forgot that the Usenet gateway doesn't work anymore.
I am wondering what software one needs for a 3705 to connect up
ordinary ASCII terminals.
Long running STCs that have allocated SPOOL on the mod-9 will be your problem.
The $MSPL will not move active stuff.
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with
It's probably a remnant of the infrastructure changes they implemented over
the weekend. Somebody forgot something? May help us down the road when
they get the kinks out.
Lots of goonies out there. Costco Walmart reporting photo site hacked,
Apple music 4 1/2 hour outage, etc., ad
I would like to add if you are not the storage administrator (the group
responsible for SMS/ACS), then contact them for assistance. They can be
helpful.
Lizette
-Original Message-
From: retired mainframer retired-mainfra...@q.com
Sent: Jul 21, 2015 10:15 AM
To: IBM-MAIN@LISTSERV.UA.EDU
In that case, you may fire at will, Mr. Gridley
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of Mike Schwab
Sent: Tuesday, July 21, 2015 2:44 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Almost emptied SDSP before deleting
The
There is nothing wrong with MOD9 and MOD3 Spool volumes. Unless that is the
standard in your shop.
And some handy JES2 Commands
$D JQ,SPOOL=(V=SPLT21,PERCENT10) show stuff less than 10% on Spool
$DA,ALL,X,DEV,V=SPL0PHshow active work on Spool
I did try the Spool Migration. It
(snip, I wrote)
To connect terminals to a 3705.
Well, maybe a terminal server instead of terminals.
I'm posting to Usenet.
(Can't be bothered.)
That is where I read it, so fine with me.
A display? Do you intend to use ISPF, CMS?
You need to provide better info.
I am hoping to run
At 14:54 -0500 on 07/21/2015, David Magee wrote about Re: JES2 SPOOL question:
Long running STCs that have allocated SPOOL on the mod-9 will be
your problem. The $MSPL will not move active stuff.
IMO, this is a design flaw in MSPL. Most of the allocated spool space
is NOT being updated even
HELP
Såvida annat inte anges ovan: / Unless stated otherwise above:
IBM Svenska AB
Organisationsnummer: 556026-6883
Adress: 164 92 Stockholm
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to
OK, I forgot that the Usenet gateway doesn't work anymore.
I am wondering what software one needs for a 3705 to connect
up ordinary ASCII terminals.
For example, what would be needed to use TSO or Wylbur on
ASCII terminals? I know this is what was done 35 years
ago, but I don't know now who
Hello,
We are installing RSU on z/OS 1.13 system and in apply check
process we encountered
below issue.
GIM38201E ** THERE IS A MODID ERROR FOR SRC ENTRY ASMADOPT IN SYSMOD
UK81531.
GIM31901ISYSMOD UK81531 DOES NOT SPECIFY SP1BAB0 ON THE PRE OR SUP
OPERAND.
SP1BAB0 IS
On 20/07/2015 9:37 PM, John McKown wrote:
Thanks for the pointer. This is a on my own project which has been put
on the back burner. I'm fighting a hardware upgrade issue at home right
now. I think the SATA interface on the motherboard of one of my systems is
getting flaky. And the old, IDE,
RESTORE the usermod
APPLY the PTF
Correct the usermod with PRE(UK81531) and any other logical changes
REEIVE the updated usermod
Apply the usermod
Cheers,
Paul Gillis
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of venkat kulkarni
Walt's method works, but I have had great success using ISPF Option 3.4 and
renaming the data set. I get a confirmation screen telling me that the file is
in use but I have the authority to bypass it if I wish. Once renamed I can
delete it.
Dan
-Original Message-
From: IBM
Down for me too
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of George Rodriguez
Sent: Tuesday, July 21, 2015 2:49 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Redbooks.IBM.com is Down
Hi MVS-L,
Can you guys check to see in the
Hi MVS-L,
Can you guys check to see in the Redbooks.ibm.com website is down?
TIA!
*George Rodriguez*
*Specialist II - IT Solutions*
*IT Enterprise Applications*
*PX - 47652*
*(561) 357-7652 (office)*
*(954) 415-7586 (mobile)*
*School District of Palm Beach County*
*3348 Forest Hill Blvd.*
*Room
Then it's not just me... Thanks!
*George Rodriguez*
*Specialist II - IT Solutions*
*IT Enterprise Applications*
*PX - 47652*
*(561) 357-7652 (office)*
*(954) 415-7586 (mobile)*
*School District of Palm Beach County*
*3348 Forest Hill Blvd.*
*Room B-251*
*West Palm Beach, FL. 33406-5869*
EP or PEP (NCP + EP) in the 3705. EP terminals corresponded to MVS device
addresses.
BTAM, TCAM, RTAM or similar in what was MVS
There were add-ons to NCP NTO or NPSI with LLC5 PAD that might achieve
something similar that made ASCII teletypes appear as SNA LU type 1, 2 or 3.
My memory may
[Sorry if some of you may read this twice – I had some trouble with my
subscription to this list due to a changed E-Mail address]
All,
on my zPDT z/OS 2.1 System I’ve recently tried to get the SMF-Exit IEFACTRT
provided in SYS1.SAMPLIB up and running. But in vain.
I’ve built with this JCL:
You got it.
Dan Blake
2967
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of william janulin
Sent: Tuesday, July 21, 2015 9:36 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: VSAM question
Would not modifying an existing DATACLASS to
Probably... That's funny!
*George Rodriguez*
*Specialist II - IT Solutions*
*IT Enterprise Applications*
*PX - 47652*
*(561) 357-7652 (office)*
*(954) 415-7586 (mobile)*
*School District of Palm Beach County*
*3348 Forest Hill Blvd.*
*Room B-251*
*West Palm Beach, FL. 33406-5869*
*Florida's Only
It will depend on the OP shop on how this will work.
So how does the ACS routine handle DBAGDC. Also, does it only include Extended
Addressability or more stuff?
I also like to have Extended Format with my Extended Addressability.
Lizette
-Original Message-
From: IBM Mainframe
Have you tried any of the suggestions?
IDCAMS RENAME using volser IPLVL2
ISPF 3.4 RENAME using volser IPLVL2 (you should get a pop up panel)
If possible, you could just init with ICKDSF your IPLVL2 pack and reload all
the datasets that need to be on it again.
Lizette
-Original
To list;
OK. I modified a dataclass to specify extended addressability but I still get
the 110 error:
DEFINE -
CLUSTER -
( -
I believe the key is using SMS and setting up a DATACLASS that supports
extended addressability (because the total size is greater than 4 GB).
Dan
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of william janulin
Sent: Tuesday,
Would not modifying an existing DATACLASS to specify Extended Addressability do
the same thing?
On Tuesday, July 21, 2015 9:32 AM, Blake, Daniel J [CTR]
dbl...@fdic.gov wrote:
I believe the key is using SMS and setting up a DATACLASS that supports
extended addressability (because
The owners of the site have been notified.
Robert Haimowitz
IBM Development Support Team (DST) Poughkeepsie
IBM z Systems and z/OS Enablement
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to
This is handy sometimes:
http://www.downforeveryoneorjustme.com/www.redbooks.ibm.com
Dana
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
The server at publibz.boulder.ibm.com. (IBM publications) is also down for
some hours now. Is this a mainframe ;-)
ITschak
ITschak Mugzach
Z/OS, ISV Products and Application Security Risk Assessments Professional
On Tue, Jul 21, 2015 at 3:33 PM, Robert Haimowitz ha...@us.ibm.com wrote:
The
Any suggestions to get around this problem would be appreciated.
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
57 matches
Mail list logo