Re: Comments in SYS1.PARMLIB

2016-08-24 Thread Peter Relson
>This was one of our big SHARE requirements and we worked hard at it. >You should be able to put comments in any SYS1.PARMLIB member now. If >you find a member that's not supported, please let us know. I would not have said that the thrust was necessarily about "any...member". Support for

Dump in 64 bit mode "Storage around GPR2 is invalid."

2016-08-24 Thread Janet Graff
When I get a CEEDUMP while running in 64 bit mode some of the register summary shows things like "GPR2. ". Why does this happen and how do I get the value of the register? Janet -- For IBM-MAIN subscribe

IBM will move stored stuff onto its new flashy boxen for free • The Register

2016-08-24 Thread Edward Gould
> http://www.theregister.co.uk/2016/08/24/ibm_new_flash_storwize_gear/ > > > IBM will move stored stuff onto its new flashy boxen for free > > Strong bait for new customers. Not good news for Dell or EMC > > IBM has

Re: Comments in SYS1.PARMLIB

2016-08-24 Thread Cheryl Watson
Hi all, There is actually a Health Check for Parmlib called ICE, but it's developed and marketed by NewEra Software. See http://www.newera-info.com. They have wonderful products, and their customers rave about them. If you're not familiar with their website, check it out for a lot of free

Re: VEHSTATS job

2016-08-24 Thread Lizette Koehler
I would contact the IBM team that ships this. This may be something they can fix. They are very helpful There is an email address for the IBM TAPETOOLs you can use. Lizette > -Original Message- > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On > Behalf Of

Re: VEHSTATS job

2016-08-24 Thread Sankaranarayanan, Vignesh
Thanks Lizette. Sent this out to IBM. The developer replied almost immediately. Very neat! - Vignesh Mainframe Infrastructure -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Lizette Koehler Sent: 24 August 2016 15:27 To:

Paging Ed Gould

2016-08-24 Thread Gabe Goldberg
Ed -- please get in touch; I'd like to confirm for attribution comments you made for article I'm writing for Destination z website on checklists. And I need your affiliation (besides being on IBM-MAIN!). Thanks, -- Gabriel Goldberg, Computers and Publishing, Inc. g...@gabegold.com 3401

Re: ESD info using ENTRY name

2016-08-24 Thread Wayne Driscoll
You need to get the EPTOKEN for the load module via the CSVQUERY service and then use that on the IEWBIND FUNC-NCLUDE,INTYPE=TOKEN call. This is required because IEWBIND has to read the pieces of the load module that aren't required for execution. ==

Re: ESD info using ENTRY name

2016-08-24 Thread Joseph Reichman
The only caveat the module has to be in memory Thanks > On Aug 24, 2016, at 11:02 AM, Wayne Driscoll wrote: > > You need to get the EPTOKEN for the load module via the CSVQUERY service > and then use that on the IEWBIND FUNC-NCLUDE,INTYPE=TOKEN call. This is > required

Re: ESD info using ENTRY name

2016-08-24 Thread Wayne Driscoll
If the module isn't in memory, then use the the INTYPE=NAME, DDNAME=,MEMBER= options which will load the module into memory and delete it when complete. == Wayne Driscoll OMEGAMON DB2 L3 Support/Development wdrisco(at)us(dot)ibm(dot)com All opinions are

Controlling allocation in IDCAMS IMPORT operation

2016-08-24 Thread Nathan Astle
Hello, I am trying to search it in IDCAMS manual if the IDCAM import operation can control the OUTDATASET allocation. Still not able to see any clue in the FM. Does anyone has any suggestions ? Meanwhile I am still searching in the manual z/OS 1.13 Nathan

Re: Comments in SYS1.PARMLIB

2016-08-24 Thread Jesse 1 Robinson
For years my fiercest hot button has been not structural syntax differences among components but the scurrilous practice of introducing a keyword change in one release that is incompatible with the previous release(s). Over the years we've seen this with various products/components. SMS

Re: ESD info using ENTRY name

2016-08-24 Thread Joseph Reichman
Didn't know the binder loads the module into memory When you say delete when the dialog with the Binder ends ? > On Aug 24, 2016, at 11:48 AM, Wayne Driscoll wrote: > > If the module isn't in memory, then use the the INTYPE=NAME, > DDNAME=,MEMBER= options which will load

Re: ESD info using ENTRY name

2016-08-24 Thread Mike Schwab
You pass to the binder at link time options that specify WHERE and HOW the program should be loaded and reused. These are stored in the PDS(E) directory. When the program is first requested, the loader program looks at the directory entry and reads it into the specified location and executes it.

Re: Controlling allocation in IDCAMS IMPORT operation

2016-08-24 Thread Jesse 1 Robinson
You don't say what degree of control you need. The OUTFILE parameter of IMPORT seems to control only volser as I read TSO HELP. OUTFILE('DNAME') - SPECIFIES THE NAME OF A DD STATEMENT THAT IDENTIFIES THE VOLUME THAT IS TO

Re: Controlling allocation in IDCAMS IMPORT operation

2016-08-24 Thread Lizette Koehler
What are the JCL and Control Cards you are using Are you doing this for a catalog or vsam file (like ksds, ld, and so forth) Provide any error messages if you have them. You can let IDCAMS dynamically allocation your files, or use IFILE, OFILE etc... Lizette > -Original Message- >

Re: SMPLOG usage

2016-08-24 Thread R.S.
Kurt, Thank you for the explanation. So, I understand SMPLOG data is "for me" and SMP/E will not suffer when it's lost. However I'm trying to understand what is suggested procedure for enduser: should I periodically (or just by x37 event) reset SMPLOG dataset? An answer for Q1 tells me SMPLOG

Re: SMPLOG usage

2016-08-24 Thread Jesse 1 Robinson
For the record, I not use SMPLOG at all. I archive SMP jobs--real ones, not CHECK jobs--for an indefinite period. I seldom need to look at old ones, but they're there if needed. . . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager

Re: Delta Ourage

2016-08-24 Thread Scott Ford
John/John, Yeppers, one has to be intelligent and open-minded to understand IT, it's people, equip etc. I keep thinking I am a odd duck, I grewup with IT since about age 5-6 , father working for Unisys. I have similar situations when managers don't understand a Mainframe isn't a PC when writing

Re: Comments in SYS1.PARMLIB

2016-08-24 Thread R.S.
W dniu 2016-08-24 o 15:11, Elardus Engelbrecht pisze: Charles Mills wrote: Plus, are there not third-party PARMLIB syntax checkers which would have been broken by the change? There are some syntax checkers from IBM, but only for *certain* parmlib members: CEEPRMxx, LOADxx and GRSRNLXX

Re: Comments in SYS1.PARMLIB

2016-08-24 Thread Elardus Engelbrecht
Charles Mills wrote: >Plus, are there not third-party PARMLIB syntax checkers which would have been >broken by the change? There are some syntax checkers from IBM, but only for *certain* parmlib members: CEEPRMxx, LOADxx and GRSRNLXX checked by 'Parmlib Processing tool' and 'Symbolic Parmlib

VEHSTATS job

2016-08-24 Thread Sankaranarayanan, Vignesh
Hello, I'm running the VEHSTPO job (part of the IBMTOOLS tape reporting jobs, aka "tapetool") with the required BVIRHSTU extract. I'm getting a 614-08 in the main report step, on the SORTIN DD. IEC214I 614-08,IFG0200Y,JOBNAME1,RPTSTEP,SORTIN,UNIT,VOLSER,

Re: Controlling allocation in IDCAMS IMPORT operation

2016-08-24 Thread Binyamin Dissen
What is your business case? What benefit would you have for this that standard RACF/acf2 controls would not provide? On Wed, 24 Aug 2016 21:35:04 +0530 Nathan Astle wrote: :>I am trying to search it in IDCAMS manual if the IDCAM import operation can :>control the

Re: Controlling allocation in IDCAMS IMPORT operation

2016-08-24 Thread Nims,Alva John (Al)
What if you pre-allocate the output VSAM data set with the new options? I think you then use the OUTDATASET parameter and If the name of the data set that you are attempting to IMPORT "TO" is different than the EXPORTED data set, then it looks like you need to specify the NEWNAME parameter.

Re: Comments in SYS1.PARMLIB

2016-08-24 Thread Charles Mills
The inconsistent PARMLIB syntax horse escaped from the barn many years ago. I am not an IBM "insider" but it is obvious to me that re-engineering every one of the PARMLIB consumers to support a uniform (and marvelous) syntax, while maintaining backward compatibility, would have been a Sisyphean

Re: SMPLOG usage

2016-08-24 Thread Kurt Quackenbush
On 8/23/2016 2:08 PM, R.S. wrote: SMPLOG is being used with DISP=MOD. That means it will grow and grow until it get full (x37 abend) and then alternative log dataset (SMPLOGA) is used. Am I right with the above? Correct. Q1. What happens when SMPLOGA is full? Is SMPLOG used again with

ESD info using ENTRY name

2016-08-24 Thread Joseph Reichman
Hi Would anyone know if it's possible to get ESD info for a CSECT using an entry point label Either with IEWBIND getd or gete Thanks -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to

Re: LOAD VTAM Logmode Table

2016-08-24 Thread Meehan, Cheryl
Jon- It looks like the command you are using is the correct command. I found this in the Manual which may or may not apply to you. "The MODIFY TABLE command can end unsuccessfully if the table being loaded is partially or entirely contained in new extents (data spaces where information is