AW: SMF/RMF records for 4hr rolling average MSU?

2019-03-05 Thread Werner Kuehnel
/ RMF Tools https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.3.0/com.ibm.zos.v2r3.erb/erb.htm Hth, Werner Kuehnel -Ursprüngliche Nachricht- Von: IBM Mainframe Discussion List Im Auftrag von John McKown Gesendet: Dienstag, 5. März 2019 21:32 An: IBM-MAIN@LISTSERV.UA.EDU Betreff

AW: AW: Where are the IBMLINK SIS fuinctions today?

2018-10-23 Thread Werner Kuehnel
Im Auftrag von Ed Jaffe Gesendet: Dienstag, 23. Oktober 2018 15:03 An: IBM-MAIN@LISTSERV.UA.EDU Betreff: Re: AW: Where are the IBMLINK SIS fuinctions today? On 10/23/2018 5:27 AM, Werner Kuehnel wrote: > And where can I look up PTFs? IBMLINK / SIS was my major website doing > this. >

AW: AW: Where are the IBMLINK SIS fuinctions today?

2018-10-23 Thread Werner Kuehnel
Thanks Barbara,you made my day. My bookmark ended after /ibmlink and that doesn't work anymore. Thanks for the new URL, I'm really happy to have IBMLINK again :-) Regards, Werner -Ursprüngliche Nachricht- Von: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] Im Auftrag

AW: Where are the IBMLINK SIS fuinctions today?

2018-10-23 Thread Werner Kuehnel
And where can I look up PTFs? IBMLINK / SIS was my major website doing this. The "Granular APAR search" doesn't work for me with PTF numbers. Regards, Werner -Ursprüngliche Nachricht- Von: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] Im Auftrag von Ed Jaffe

AW: Netview Submit JCL

2018-05-14 Thread Werner Kuehnel
Hello Venkat, this is how it works at our site: /*/ /* FUNCTION: submits job*/ /*/ 'SUBMIT

AW: Delete dataset catch-22

2018-02-08 Thread Werner Kuehnel
- ADMIN - PURGE Werner Kuehnel -Ursprüngliche Nachricht- Von: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] Im Auftrag von Mark Pace Gesendet: Donnerstag, 8

AW: AW: CA7 with service now

2017-06-30 Thread Werner Kuehnel
? On 29/06/2017 7:11 PM, Werner Kuehnel wrote: > Nathan, > I don't know ServiceNow, but we create automatically tickets for abending > jobs or jobs with RC > 4 in JIRA ticketing system. > This is done with REST services and cURL from a REXX (started by NetView). > Probably Serv

AW: CA7 with service now

2017-06-29 Thread Werner Kuehnel
Nathan, I don't know ServiceNow, but we create automatically tickets for abending jobs or jobs with RC > 4 in JIRA ticketing system. This is done with REST services and cURL from a REXX (started by NetView). Probably ServiceNow offers also a REST API you can use. If you need more information

Antwort: 4-hour MSU rolling average

2015-10-20 Thread Werner Kuehnel
Here's a little REXX subroutine to get the values: get4hrAvgMSU: MSU_4H = 0 MSU_GRP = 0 CVT = C2d(Storage(10,4)) /* point to CVT */ RMCT= C2d(Storage(D2x(CVT+604),4))/* point to RMCT*/ RCT = C2d(Storage(D2x(RMCT+228),4)) /* Resource Ctrl

Re: SMF30HVO

2015-08-20 Thread Werner Kuehnel
see). OA44690 doesn't apply to us, we still avoid working with PDS/Es and have just a handful private libs, beside the z/OS PDSEs. Anyway, thanks for the hint. Werner Kuehnel Von:Staller, Allan allan.stal...@kbmg.com An: IBM-MAIN@LISTSERV.UA.EDU, Datum: 19.08.2015 15:37 Betreff

SMF30HVO

2015-08-19 Thread Werner Kuehnel
guarded virtual storage. Does it mean that my real storage is more heavily used now and the UIC goes down? Or do I misinterpret it? For example RMF: 1.134194304 bytes 2.1 7340032 bytes The values are from type 30 subtype 2 interval records (15 min). Regards, Werner Kuehnel

Antwort: Re: z/OS Platform Software Products on ... Tape?

2015-05-12 Thread Werner Kuehnel
is an extended period for download of a server pac or product pac. Why not give a time span of 8-10 weeks? I'm always afraid to miss the time, especially if I order before a vacation. Werner Kuehnel Von:John Eells ee...@us.ibm.com An: IBM-MAIN@LISTSERV.UA.EDU, Datum: 12.05.2015 13:39 Betreff

Antwort: Intermittent, not consistently reproducible problems with PDSEs on z/OS V2R1 (incl. infrequent S0F4-20 RSN 1C0752EE ABENDs)

2015-03-20 Thread Werner Kuehnel
Karl, did you see APAR OA24679? Regards, Werner Von:Karl Henn k.h...@seg.de An: IBM-MAIN@LISTSERV.UA.EDU, Datum: 20.03.2015 14:13 Betreff:Intermittent, not consistently reproducible problems with PDSEs on z/OS V2R1 (incl. infrequent S0F4-20 RSN 1C0752EE ABENDs) Gesendet von:

FTP of EBCDIC file

2014-09-08 Thread Werner Kuehnel
. A second ftp (within z/OS) then splits up the records at x'0D25', but additionally at byte 582, which is wrong when a record flows over into the next record. All attempts to get the right format failed up to now. Does anyone has an idea how to accomplish this? Werner Kuehnel

Re: FTP of EBCDIC file

2014-09-08 Thread Werner Kuehnel
:43:16 +0200, Werner Kuehnel wrote: I have a file on a WIN server with variable data records in EBCDIC and the correct end-of-line marker of x'0D25'. In the end I need a file with LRECL=582, RECFM=VB. When I ftp this file binary with quote site lrecl=582 recfm=fb all records are written

Re: FTP of EBCDIC file

2014-09-08 Thread Werner Kuehnel
Discussion List IBM-MAIN@LISTSERV.UA.EDU On Mon, Sep 8, 2014 at 8:44 AM, Norbert Friemel nf.ibmm...@web.de wrote: On Mon, 8 Sep 2014 08:12:43 -0500, Paul Gilmartin wrote: On Mon, 8 Sep 2014 11:43:16 +0200, Werner Kuehnel wrote: I have a file on a WIN server with variable data records

Re: FTP of EBCDIC file

2014-09-08 Thread Werner Kuehnel
I doubt they can handle that file with AMATERSE, they aren't very flexible introducing alternatives. Thanks, Werner Von:Bob Shannon bshan...@rocketsoftware.com An: IBM-MAIN@LISTSERV.UA.EDU, Datum: 08.09.2014 15:52 Betreff:Re: FTP of EBCDIC file Gesendet von: IBM Mainframe

Re: FTP of EBCDIC file

2014-09-08 Thread Werner Kuehnel
@LISTSERV.UA.EDU On Mon, Sep 8, 2014 at 8:46 AM, Werner Kuehnel werner.kueh...@mannheimer.de wrote: It's not my creation, it was delivered by a bank for a test. Thanks for your suggestions, but if there are no standard ftp commands I refuse to work with that file. Anyway, I tested your way and it almost

Antwort: Re: FTP of EBCDIC file

2014-09-08 Thread Werner Kuehnel
Nothing is unclear, probably I chose the wrong words. What I meant was I doubt that they change their standard procedures to provide the file. Werner Von:Bob Shannon bshan...@rocketsoftware.com An: IBM-MAIN@LISTSERV.UA.EDU, Datum: 08.09.2014 16:44 Betreff:Re: FTP of EBCDIC

Antwort: JES3 job ids

2014-07-24 Thread Werner Kuehnel
On our JES3 system (z/OS 1.13) the jobid for TSO users is TSUn for inactive (just output on spool) and active users. n are 5 digits. Haven't seen anything else in the past. Werner Kuehnel Von:Barbara Nitz nitz-...@gmx.net An: IBM-MAIN@LISTSERV.UA.EDU, Datum: 24.07.2014

Re: Installing IBM HTTP Server Powered by Apache

2014-04-09 Thread Werner Kuehnel
Dana, if the HTTP Server is the FMID HHAP85P, then I did the install without the Installation Manager, just plain SMP/E. There is no need to use it. However, if you already have HHAP700 installed within your z/OS SMP/E environment, then you need a separate SMP/E set of datasets Werner Von:

Re: Installing IBM HTTP Server Powered by Apache

2014-04-09 Thread Werner Kuehnel
BTW, there is a conversion tool for convert httpd.conf from Domino to Apache. This is especially useful for the directives, as they have to be Regex in Apache: ftp://public.dhe.ibm.com/s390/zos/tools/cmt/ Werner Von:Dana Mitchell mitchd...@gmail.com An: IBM-MAIN@LISTSERV.UA.EDU,

Re: Installing IBM HTTP Server Powered by Apache

2014-04-09 Thread Werner Kuehnel
to this thread, this isn't a very common practice yet. Dana On Wed, 9 Apr 2014 08:29:33 +0200, Werner Kuehnel werner.kueh...@mannheimer.de wrote: Dana, if the HTTP Server is the FMID HHAP85P, then I did the install without the Installation Manager, just plain SMP/E. There is no need to use

Re: Notification of New Function APARs

2013-10-31 Thread Werner Kuehnel
Have someone been able to find the file with old NewFunction Apars mentioned on the last page of the document? My search always ends with no document. Obtaining Older New Function APAR Numbers Once you have a subscription for all the future New Function APARs, you may want to see the prior New

Re: Low priority workload

2013-02-26 Thread Werner Kuehnel
The analysis was done by an external consultant at that time and the graphs show spikes of that magnitude for that service class/resource group. Werner Kühnel IMD-Gesellschaft für Informatik und Datenverarbeitung mbH Augustaanlage 66 68165 Mannheim Tel: +49.621.457-4885, Fax: -4046 E-Mail:

Re: Low priority workload

2013-02-20 Thread Werner Kuehnel
(by REXX) different service classes (discretionary, light brake, heavy brake), dependent on the 4h-average values of our production lpar group (2 lpars). This works pretty well for us. - - Werner Kuehnel Spezialist in der Abteilung Betrieb/Support IMD-Gesellschaft für Informatik und

Re: Low priority workload

2013-02-19 Thread Werner Kuehnel
, Werner Kuehnel IMD-Gesellschaft für Informatik und Datenverarbeitung mbH Augustaanlage 66 68165 Mannheim Tel: +49.621.457-4885, Fax: -4046 E-Mail: werner.kueh...@mannheimer.de IMD-Gesellschaft für Informatik und Datenverarbeitung mbH Sitz Mannheim, Amtsgericht Mannheim HRB 7460