It looks to be a cipher issue.
You can try to change the parameter "cipher_list" in
/usr/local/pf/conf/radiusd/eap.conf to something like that: cipher_list
= "ALL:!EXPORT:!eNULL:!SSLv2"
And restart radius and retry.
Regards
Fabrice
Le 2018-07-19 à 23:08, Amjad Ali a écrit :
Hi Fabrice,
Hi Fabrice,
Many thanks for the response, appreciate it.
Below is the output from
raddebug -f /usr/local/pf/var/run/radiusd.sock -t 3600
thank you.
(76) Fri Jul 20 10:40:04 2018: Debug: Received Access-Request Id 1 from
10.10.51.169:1812 to 10.10.50.233:1812 length 119
(76) Fri Jul 20
PEBCAK...
A couple of edits I had made (one adding text to signin.html, and one that
predated me made to challenge.html) had blocked pages from being upgraded
and in doing so confused the button schema and workflow of AUP being before
and now not on the same page as signin.
Thanks to the as ever
Hello Ali,
you need to paste the raddebug output.
raddebug /usr/local/pf/var/run/radiusd.sock -t 3000
Regards
Fabrice
Le 2018-07-19 à 02:43, Amjad Ali via PacketFence-users a écrit :
Hi everyone,
I have setup a packetfence server in lab environment with just one
switch from edge core
Hi everyone,
I am discovering PacketFence to build a Proof Of Concept (PoC) but i am stucked
in basics stuffs.
Right now, un client unregistered is setted within registration vlan.
Once is get registered, a radius authentication is done and the client is put
within the IT or Financial vlan
Hi everyone,
I have setup a packetfence server in lab environment with just one switch
from edge core 4610-54P running picos NOS from pica8 with 802.1X support.
I then connected a laptop running windows XP with the switch port but
getting "eap: No mutually acceptable types found"
I have