Re: [Powernet] [EXTERNAL] Re: SRD settings question

2018-04-18 Thread Creamer, Charles E via Powernet
Browns Ferry does not use the clock function Chuck Creamer Health Physicist Radiation Protection Tennessee Valley Authority; Browns Ferry Nuclear Plant P.O. Box 2000 (Mail Stop NAB-1G-BFN) Decatur, Al. 35609-2000 256.729.2983 (w) cecrea...@tva.gov [https://lakeinfo.tva

[Powernet] Looking for Surplus Hand and Foot Monitors

2018-04-24 Thread Creamer, Charles E via Powernet
Looking for anyone that switched over to the hand and foot monitors with plastic detectors and have surplus gas ones they would like to get rid of. With the high backgrounds we have at BFN at the areas we need to use them I think we would be better off with the gas detectors. Chuck Creamer Hea

Re: [Powernet] Hood/Skull cap use

2018-05-10 Thread Creamer, Charles E via Powernet
Browns Ferry also allows it with the same limitations as South Texas Project. Chuck Creamer Health Physicist Radiation Protection Tennessee Valley Authority; Browns Ferry Nuclear Plant P.O. Box 2000 (Mail Stop NAB-1G-BFN) Decatur, Al. 35609-2000 256.729.2983 (w) cecrea...@tva.gov

Re: [Powernet] Personal Air Samplers

2018-05-18 Thread Creamer, Charles E via Powernet
Browns Ferry just calibrates them annually. No pre or post test Chuck Creamer Health Physicist Radiation Protection Tennessee Valley Authority; Browns Ferry Nuclear Plant P.O. Box 2000 (Mail Stop NAB-1G-BFN) Decatur, Al. 35609-2000 256.729.2983 (w) cecrea...@tva.gov [

Re: [Powernet] Alpha Determination

2018-06-05 Thread Creamer, Charles E via Powernet
Browns Ferry uses a portable instrument and a sample holder/jig as David suggested below. Our portable alpha meters have a scaler function. Works pretty well and a lot easier to decon the jig than a scaler Chuck Creamer Health Physicist Radiation Protection Tennessee Valley Authority; Browns

Re: [Powernet] Delta Suit Benchmark

2018-08-23 Thread Creamer, Charles E via Powernet
Browns Ferry is the same. They are only used here on CRDs Chuck Creamer Health Physicist Radiation Protection Tennessee Valley Authority; Browns Ferry Nuclear Plant P.O. Box 2000 (Mail Stop NAB-1G-BFN) Decatur, Al. 35609-2000 256.729.2983 (w) cecrea...@tva.gov [https:/

Re: [Powernet] Respirator qualification tracking

2018-09-11 Thread Creamer, Charles E via Powernet
This is tracked in our LMS system. LMS has in interface with HIS-20 so the information will be deposited there as well Chuck Creamer Health Physicist Radiation Protection Tennessee Valley Authority; Browns Ferry Nuclear Plant P.O. Box 2000 (Mail Stop NAB-1G-BFN) Decatur, Al. 35609-2000 256.729

Re: [Powernet] Test Post

2018-09-28 Thread Creamer, Charles E via Powernet
Seems to be working. Thanks for keeping this running Chuck Creamer Health Physicist Radiation Protection Tennessee Valley Authority; Browns Ferry Nuclear Plant P.O. Box 2000 (Mail Stop NAB-1G-BFN) Decatur, Al. 35609-2000 256.729.2983 (w) cecrea...@tva.gov NOTICE: This electronic message tran

Re: [Powernet] How do you count for Alpha when beta-Gamma activity is greater than your limits for count room equipment?

2018-10-21 Thread Creamer, Charles E via Powernet
At Browns Ferry we use an Alpha frisker for high activity smears. We have a Plexiglas jig that fits over the smear and holds the probe while the smear is being counted. Does pretty well at keeping the probe from being contaminated and the jig is easily cleaned up after the tech is finished C

Re: [Powernet] How do you count for Alpha when beta-Gamma activity is greater than your limits for count room equipment?

2018-10-23 Thread Creamer, Charles E via Powernet
Yes, but we have to do a 10 minute count. The Ludlum alpha frisker that is used has the scaler option and have a Plexiglas jig used to hold the probe. From: Diehl, John Sent: Sunday, October 21, 2018 5:15 PM To: Creamer, Charles E ; powernet@hpspowernet.org Cc: Billings, Dewayne Subject: RE: [

Re: [Powernet] Quick Benchmarking on ED's

2018-11-02 Thread Creamer, Charles E via Powernet
Browns Ferry uses a mixture of DMC2000 and DMC3000. Our DMC200s are getting old. The workers prefer the DMC2000 mainly because if the clip and are hording them. I personally like them as easier to read >From what I have heard the active antenna will work for diving with a DMC3000 >and a trans

Re: [Powernet] VSDS

2019-01-23 Thread Creamer, Charles E via Powernet
Brad, I echo Phillips suggestion on the setup. Will make it much easier to maintain and find surveys if they are cataloged properly. Use simple names for filenames and will make it easier to retrieve maps in the future Chuck Creamer Health Physicist Radiation Protection Tennessee Valley Aut

Re: [Powernet] RP field instrument tamper seals

2019-04-11 Thread Creamer, Charles E via Powernet
Browns Ferry / TVA does not use tamper seals on RP field instruments Chuck Creamer Health Physicist Radiation Protection Tennessee Valley Authority; Browns Ferry Nuclear Plant P.O. Box 2000 (Mail Stop NAB-1G-BFN) Decatur, Al. 35609-2000 256.729.2983 (w) cecrea...@tva.gov

Re: [Powernet] Primary Containment Access Control

2019-07-25 Thread Creamer, Charles E via Powernet
Like Fermi our procedures (we have one for each unit entry and closeout) are maintained by Operations. RP has its requirements embedded in this procedure Chuck Creamer Health Physicist Radiation Protection Tennessee Valley Authority; Browns Ferry Nuclear Plant P.O. Box 2000 (Mail Stop NAB-1G-B

Re: [Powernet] Diving Remote Monitoring

2019-08-23 Thread Creamer, Charles E via Powernet
We also used the AWM and active dive antenna. Used the DMC3000 and had great coverage. Did a few weeks of diving in the equipment pit for an EPU outage dryer cut up and works great. Much better than the old iMUX. Was getting 4-8 second response on each dosimeter as compared to 30-40 seconds

Re: [Powernet] Columbia benchmarking question - Drones

2019-11-06 Thread Creamer, Charles E via Powernet
Have not used for Surveys in High Rad areas. Have used it for an inspection in Locked High Radiation Area at Browns Ferry. TVA has a corporate group that does it and the sites do not operate them. We were not involved in the approval process but can get you a contact in the group that operate

Re: [Powernet] Use of DMC3000 with Diving

2020-01-14 Thread Creamer, Charles E via Powernet
They worked great at Browns Ferry. Used them the last outage when we cut up our Steam dryer as part of EPU. Used them with the active dive antenna and AWM. That evolution consisted of almost three weeks of diving. The updates much faster than the old system as did not have to deal with the iM

[Powernet] REP Van Controllers

2020-01-23 Thread Creamer, Charles E via Powernet
Browns Ferry recently got two new REP vans for use during radiological emergencies and drills. The old vans had room for two players and a controller during drills as it would seat three individuals. The new vans only have two seats which would be used to for the two techs staffing the van.

[Powernet] Non Radiological Respirator use into the RCA

2020-03-15 Thread Creamer, Charles E via Powernet
How does your site / utility handle the use of non-radiological respirator use in the RCA. Asbestos or chemical hazards are examples where the respirator could be required for a non-radiological condition. At Browns Ferry the respirator user would have to meet the requirements for any respira

Re: [Powernet] Quick Benchmarking Question from Columbia

2020-03-15 Thread Creamer, Charles E via Powernet
Not for Browns Ferry. From: Powernet On Behalf Of Kinmark, Michael L. via Powernet Sent: Thursday, March 12, 2020 1:57 PM To: 'Powernet@hpspowernet.org' (Powernet@hpspowernet.org) Cc: Kinmark, Michael L. Subject: [Powernet] Quick Benchmarking Question from Columbia This is an EXTERNAL EMAIL