as possible.
John Ainsley
Radiation Protection Supervisor - RP Instruments
Fermi-2 Nuclear Power Plant
734-586-5862 Office
734-457-1250 Pager
john.ains...@dteenergy.com <mailto:john.ains...@dteenergy.com>
[http://quest.dteco.com/news/images/newBrandingStory.jpg]
PROPRIETARY, CONFIDENTIAL OR PRIV
Michael,
We use DMC2000's set at 100 dose and 100mr/hr rate for Fast Entry emergencies.
For ERO we use DMC's as well if entry is into RCA but in general we zero and
assign PIC's at facilities located away from RCA.
John Ainsley
Radiation Protection Supervisor - RP Instruments
Fermi-2 Nuclear
Got it.
John Ainsley
Radiation Protection Supervisor – RP Instruments
Fermi-2 Nuclear Power Plant
734-586-5862 Office
734-457-1250 Pager
john.ains...@dteenergy.com
PROPRIETARY, CONFIDENTIAL OR PRIVILEGED COMMUNICATION ***
This communication may contain proprietary, privileged or confidential
difference in equipment performance at this
time.
Hope this helps,
John Ainsley
Radiation Protection Supervisor - RP Instruments
Fermi-2 Nuclear Power Plant
734-586-5862 Office
john.ains...@dteenergy.com <mailto:john.ains...@dteenergy.com>
[http://quest.dteco.com/news/images/newBrandingSto
good program, could you please provide a
contact name and phone/email? I believe our program is solid regarding
ownership and responsibility's. My only reservation is the ability to acquire
replacement parts for older equipment. We are slowly replacing RMS as our
budget allows.
John Ain
Fermi 2 Radiation Protections Instrument technicians perform the detector
radiological calibrations on plant installed radiation monitoring systems. I
performs the electronic cal/functionals.
John Ainsley
Radiation Protection Supervisor - RP Instruments
Fermi-2 Nuclear Power Plant
734-586-5862
and test equipment
background or degree.
Additionally our RP instrument techs must become fully qualified Senior RP
Techs because they are part of the RP organization not I
John Ainsley
Radiation Protection Supervisor - RP Instruments
Fermi-2 Nuclear Power Plant
734-586-5862 Office
734-457-1250
Fermi - The AXM functional is quarterly and TRM is the governing document.
From: Powernet On Behalf Of Paciello, Lara R
via Powernet
Sent: Wednesday, May 1, 2019 3:33 PM
To: powernet@hpspowernet.org
Cc: Paciello, Lara R
Subject: Re: [Powernet] [EXTERNAL] High Range Noble Gas Monitors
Fermi does not.
John Ainsley
Radiation Protection Supervisor - RP Instruments
Fermi-2 Nuclear Power Plant
734-586-5862 Office
734-457-1250 Pager
john.ains...@dteenergy.com <mailto:john.ains...@dteenergy.com>
[cid:image001.jpg@01D4C467.C46E3720]
PROPRIETARY, CONFIDENTIAL OR PRIV
Fermi-2 performs MCA calibration annually, at a minimum.
John Ainsley
Radiation Protection Supervisor - RP Instruments
Fermi-2 Nuclear Power Plant
734-586-5862 Office
734-457-1250 Pager
john.ains...@dteenergy.com <mailto:john.ains...@dteenergy.com>
[cid:image001.jpg@01D4C467.C4
10 matches