W dniu niedziela, 19 marca 2017 00:28:18 UTC+1 użytkownik Andrew David Wong
napisał:
> -BEGIN PGP SIGNED MESSAGE-
> Hash: SHA512
>
> On 2017-03-18 09:24, Grzegorz Chodzicki wrote:
> >
> >
> > On 03/18/2017 05:21 PM, Unman wrote:
> >> On Sat, Mar 18, 2017 at 08:59:29AM -0700, Grzesiek Ch
On 03/19/2017 01:40 AM, Jean-Philippe Ouellet wrote:
> On Tue, Mar 14, 2017 at 7:11 PM, haaber wrote:
>> I dont't have any e820 pci device as far as I know, but shutdown is
>> definitely a problem. xfce shuts down, and then I have a black screen
>> with a blinking cursor, and, afaik unless I brut
On Tue, Mar 14, 2017 at 7:11 PM, haaber wrote:
> I dont't have any e820 pci device as far as I know, but shutdown is
> definitely a problem. xfce shuts down, and then I have a black screen
> with a blinking cursor, and, afaik unless I brutally remove electricity.
> No clue if this is related to Gr
-BEGIN PGP SIGNED MESSAGE-
Hash: SHA512
On 2017-03-18 09:24, Grzegorz Chodzicki wrote:
>
>
> On 03/18/2017 05:21 PM, Unman wrote:
>> On Sat, Mar 18, 2017 at 08:59:29AM -0700, Grzesiek Chodzicki wrote:
>>> W dniu sobota, 18 marca 2017 15:08:35 UTC+1 użytkownik Unman napisał:
On Sat,
>>> Have you tried the solution suggested here before of shutting down other
>>> vms first, then sys-usb and sys-net? Andrew, I think, posted a simple
>>> script that he uses. I suspect that that will have more impact with
>>> fewer consequences than this proposal, but user experience will be key
>
On 03/18/2017 05:21 PM, Unman wrote:
> On Sat, Mar 18, 2017 at 08:59:29AM -0700, Grzesiek Chodzicki wrote:
>> W dniu sobota, 18 marca 2017 15:08:35 UTC+1 użytkownik Unman napisał:
>>> On Sat, Mar 18, 2017 at 03:41:49AM -0700, Grzesiek Chodzicki wrote:
I've experienced this issue myself and I
On Sat, Mar 18, 2017 at 08:59:29AM -0700, Grzesiek Chodzicki wrote:
> W dniu sobota, 18 marca 2017 15:08:35 UTC+1 użytkownik Unman napisał:
> > On Sat, Mar 18, 2017 at 03:41:49AM -0700, Grzesiek Chodzicki wrote:
> > > I've experienced this issue myself and I saw some people complaining
> > > about
W dniu sobota, 18 marca 2017 15:08:35 UTC+1 użytkownik Unman napisał:
> On Sat, Mar 18, 2017 at 03:41:49AM -0700, Grzesiek Chodzicki wrote:
> > I've experienced this issue myself and I saw some people complaining about
> > it on the mailing list. Sometimes Qubes takes forever to poweroff.
> >
> >
On Sat, Mar 18, 2017 at 03:41:49AM -0700, Grzesiek Chodzicki wrote:
> I've experienced this issue myself and I saw some people complaining about it
> on the mailing list. Sometimes Qubes takes forever to poweroff.
>
> The issue is caused by the fact that for some unknown reason machines with
> P
I've experienced this issue myself and I saw some people complaining about it
on the mailing list. Sometimes Qubes takes forever to poweroff.
The issue is caused by the fact that for some unknown reason machines with PCI
devices attached take forever to shutdown and sometimes need to be manually