Hi Chris, did you try the analyzer filter? Filtering one file on IT and the
other on FT should do what you want with no hassle.
-Matt
On Feb 5, 2012 8:35 PM, Chris Rath chrisr...@gmail.com wrote:
Hey everybody:
I have a bunch of LTQ-FT data with alternating MS1 scans in the IT or
FT cells. I
Hi Luis,
Thanks for the heads up. It never occurred to me to look in cgi-bin
for the config files, I was looking for them in etc. Either way, I
have it working now, although for the sake of others with similar
problems, I should point out that I needed to add an extra line, and
modify your config
For others struggling to get the tutorial to work on a Linux
installation, note that the tandem.xml parameters file that you
download for the tutorial data contains on line 6
note type=input label=list path, default parametersC:
Hi James,
I indeed forgot to include data_dir as part of my answer; glad that
you found that and got it to work.
And yes, Petunia resolves to absolute path names by default as an
extra measure of security.
Cheers,
--Luis
On Mon, Feb 6, 2012 at 7:07 AM, sirlark jgdom...@gmail.com wrote:
Hi
Hi James,
Thanks for the heads-up!
The tutorial was written with a Windows installation in mind; I have
added a note in the tutorial alerting users to modify file locations
and parameters if they are using another system.
Cheers,
--Luis
On Mon, Feb 6, 2012 at 7:26 AM, sirlark
Announcing the availability of Trans-Proteomic Pipeline (TPP) Rapture 4.5.
2
Now available is a minor update to the Trans-Proteomic Pipeline (TPP)
software, release 4.5.2 (4.5 revision 2) which addresses a number of issues
identified with version 4.5.1. All TPP users are *strongly *urged to