Hello Dave, I hope the following will help you
REN calculation for DC resistance
For 0-100VDC
REN=25 megohms/minimum DC resistance
For 100-200VDC
150 kilohms/minimum DC resistance
For Ringer type B
AC REN=8000/mim. on-hook AC imped for lowest frequency
AC REN=8000/Min. on-hook AC imped. for
From: Christopher Saleem, 103423,250
TO: Roger Prenger, INTERNET:pren...@phx.sectel.mot.com
DATE: 11/21/96 10:45 AM
RE: Copy of: Part 68, Telco Power Draw
Hi Roger,
The max power that a single line loop start device is tested against in FCC part
68 is 42.5 Vdc at 24 mA, 52.5Vdc
-- Forwarded Message --
From: Duane J Marcroft, INTERNET:dm...@crl.com
TO: Rene Debets, INTERNET:rene_deb...@msn.com
CC: Treg, INTERNET:TREG@WORLD.STD.COM
DATE: 3/10/97 12:47 AM
RE: RE: U.K. Complex Impedance Network for Measuring Return Loss
Sender:
Rob
1. For US, TSB 31A (or the latest version) would help
2. For Canada, CS03 issue 8
3. For Europe second final draft prTBR 21(Oct 1997) would be a good
guide.
These are some books that help me. Hope this will help you.
Christopher Saleem
EMC Technology Services, Inc.
EMC Technology Services is looking for a Product Safety Engineer. Must have
+3 years revalent experience in UL 1950. Good communication skills. College
degree or AS with experience required.
Fax resume to HR
EMC Technology Services, Inc.
49000 Milmont drive
Fremont, CA 94538.
Phone:
Hi Treggers,
Can someone recommend a laboratory where I could do GOSIP conformance
testing for terminal devices.
Thanks for any help in this regard.
Christopher
for the templates but they prefer to
sell me a new scope.
Thanks in advance for any help in this regard.
Regards
Christopher Saleem
telecom equipment based on international telecom test standards, preparing test documentations, compiling test reports, and assisting in country certification.
Please send me resumes if you know someone that fit the description. No phone calls please.
Christopher Saleem (Senior Compl. Engr
?
Thanks for your help
Christopher Saleem (Senior Compl. Engr.) | |
E-mail: csal...@cisco.com | |
Phone : 408-527-8736 ||| |||
Fax:(408) 526-8348 | |
210 West Tasman Drive, MS SJ-F/1..:|||:...:|||:..
San Jose, CA 95134-1706
of my questions on
Treg.
This is my personal opinion.
Regards
Christopher Saleem
Senior Compliance Engineer
Cisco Systems, Inc.
Reply-To: treg@world.std.com
Vic,
Calibration vendor audits is a hot topic for many treg participants
from accredited EMC laboratories.
By open discussion
impedance of the DC
loop which must be 2Kohms or greater for 75Vrms/16Hz.
These tests are for 2-wire analog lines.
Christopher Saleem
At 10:19 AM 10/1/98 -0500, Pete Van Raalte wrote:
TREGers,
I have contradictory information on Japanese requirements for 2-
or 4-wire analog ring-down lines
I got this today.
Please ignore this message since I inadvertently sent it to TREG.
Christopher
Linda are you referring to the data output power measurements for JATE
Analog modems?(blue book). These measurements call for the analog modem to
be sending a pattern of 0, 1, 1:1.
Christopher Saleem
At 04:59 PM 9/8/99 -0400, lbott...@aol.com wrote:
I have a very basic question. Analog
mail or fax your resume.
Christopher Saleem
e mail:csal...@cisco.com
Phone:408-527-8736
Fax: 408-527-7234