G'day,
We recently had an issue with nfiles on our HP-UX 11i (UV10.0.16)
system, where we hadn't been increasing nfiles after adding extra
UniVerse users and were getting close to the nfiles limit. We've now
adjusted nfiles accordingly, but realised we don't know whether phantoms
should be taken
Looks like the Digest system isn't working properly - I'm getting
individual posts instead of the Digest.
David Norman
Senior Software Engineer
SA Ambulance Service
Box 3, GPO
Adelaide, South Australia 5001
*+61 8 8274 0384
* fax +61 8 8271 4844
* [EMAIL PROTECTED]
... and as well as restoring the Digest function, any chance of the
Digest being in some logical sequence again ? It's rather hard to follow
threads when the answers come before the question ...
David Norman
Senior Software Engineer
SA Ambulance Service
Box 3, GPO
Thanks to all who responded - NOTIFY ON seems to have done the trick,
despite some people saying it didn't work for them, with the added bonus
of the spawned phantom reporting when it's finished.
David Norman
Senior Software Engineer
SA Ambulance Service
Box 3, GPO
UV 10.0.16 (Information) HP-UX 11i
We have a permanently-running phantom, which needs to periodically start
another phantom, with both phantoms running independently. When the 2nd
phantom stops, that process becomes a zombie until the original phantom
stops (which is preferably just about never).
Date: Wed, 15 Aug 2007 19:08:52 +
From: [EMAIL PROTECTED]
Subject: [U2] [UV] what files does a user have open
Hi all,
UV10.1.8
PICK FORMAT
HPUX 11
How do I go about seeing what files a user has open?
Thanks
From your UniVerse home account:
PORT.STATUS PID FILEMAP
The change in functionality was documented at 10.0 as a GTAR fix. As
there are only 24 hours in a day, the logic was that MT shouldn't go
above 24 hours. I recall there was discussion on the list about this at
the time.
David Norman
Senior Software Engineer
SA Ambulance
This (IMO unwanted) change in functionality occurred at 10.0. I have
written a user conversion to return the time greater than 24 hours:
01: SUBROUTINE U2134(ANSWER,STATUS,DATA,CONVTYPE)
0002: * OCONV to show hours 24 after UV10 changes hh:mm
0003: *
0004: * CATALOG AS $2134 e.g. CATALOG
UV 10.0.16 (Information) HP-UX.
I have a program that processes incoming XML quite happily using various
.ext extraction files.
I'm not sure, however, what XML commands need to be run if an XML
command has an error.
For instance, if the PrepareXML fails, do I have to do a ReleaseXML ?
And if the
UV10.0.16 (Information) HP-UX.
I have a dynamic file where every group is badly overflowed. Each record
size is between 5k and 6k, so a group size of 2048 or 4096 can't contain
a whole record.
I'm not so much concerned about performance as disk space - when I purge
the file, hardly any disk space
Thanks to Brian, Sara, Mark, Charles and Baker for your responses.
I hope Brian and Charles have hit the nail on the head. I did manage to
create an infinitely recursive subroutine call, exactly as Charles said,
by reusing code from a different program with slightly different
structure (GOTO
UV 10.0.16 (Information) HP-UX 11.
I am developing a new phantom that will run 24x7 until told to stop. I
have many phantoms running this way.
The new phantom won't run for more than about 12 hours no matter what
time started, when it aborts with a Runtime Stack Overflow, pointing to
a quite
What's the best way of outputting XML to a file (uv 10.0.16, HP-UX) ? I
may need to output a DTD, which Cedarville's Download doesn't do, and
the uv manual says to send to HOLD or a COMO, but then the output file
contains extraneous lines (blanks, and count of records listed) that
need to be
We have purchased extra licences for our UV 10.0.16 system, and have
discovered on our test system that we need to stop UniVerse in order to
install them, otherwise we get an abnormal termination. Previously under 9.6
this could be done dynamically with all users logged on, and I am advised
that
I know I'm probably going over old ground again, but what's the present
state of play for UniVerse on HP-UX connecting to SQL Server on w2000/2003
to update tables ?
Do I need middleware ? If so, what is recommended ?
UV10.0.16 HP-UX 11
Thanks,
David Norman
Senior
Crashes on 10.0.16 HP-UX if folding on 1 character, OK if folding on
2characters.
David Norman
Senior Software Engineer
SA Ambulance Service
Box 3, GPO
Adelaide, South Australia 5001
*+61 8 8274 0384
fax +61 8 8271 4844
* [EMAIL PROTECTED] mailto:[EMAIL PROTECTED]
Thanks, Adrian Louis.
I should have remembered about making the line longer to allow for control
characters - I do this for CSV files at times.
Mike, I do SETPTR mode 3 CAPTURING HOLD.ID, and later on SPOOL HOLD
FIELD(HOLD.ID,' ', 2). Can't remember why the FIELD is necessary, but it
all works
Thanks to Wol, Anthony and Andre. I have passed your suggestions on to our
facilities management people (who were talking about Cyclades).
Regards,
David Norman
Senior Systems Engineer
SA Ambulance Service
Box 3, GPO
Adelaide, South Australia 5001
*+61 8 8274 0384
fax +61
Happy Australia Day !
HP-UX 11i, UV10.
We currently use HP DTCs (Datacommunications and Terminal Controllers) to
provide both connectivity for dumb terminals, and binary or ASCII I/O for
various black boxes, PCs and printers under the control of daemons. HP are
discontinuing support for these
We have recently upgraded our HP-UX systems, from old boxes that ran at
10Mb/s half duplex, to new ones that run at 100Mb/s full duplex. We have
quite a few terminals, which either run at 10Mb/s half duplex, or talk
serially to HP terminal servers which run at 10Mb/s half duplex.
Since the
Does anyone know if there is a later version of the Maximising Performance
for UniVerse Systems technical bulletin 74-0107 than the v9.5/6 versions on
IBM's site ? I am particularly interested in UV 10.0.16 on HP-UX 11i, if
there are any differences.
Thanks,
David Norman
We are preparing to migrate from our old HP-UX system running UV 9.4 HP-UX
10.20 to our new system running UV 10.0.16 HP-UX 11i and are doing some file
consistency checks before migration.
We have noticed some bizarre behaviour when uvfixfile is running on a select
list of dynamic files.
We
Karl,
As far as I know there isn't an OS solution - the easiest way I found was to
add a $OPTIONS TIME.MILLISECOND to each program and re-compile. Another
option is to use INT(TIME()) in each statement.
David Norman
Senior Systems Engineer
SA Ambulance Service
Box 3, GPO
23 matches
Mail list logo