Just to clarify. If the battery monitoring is enabled on the shimmer with
the SET_PMUX_COMMAND and acceleration data is being collected
simultaneously the resultant output should be garbage? In order to get the
battery state while collecting data I need to modify the boiler plate app
to multiplex the two signals.

Best,

Nick

On Mon, Apr 16, 2012 at 1:07 AM, mike healy <[email protected]> wrote:

> Hi Nick,
>
> Enabling the voltage monitoring is available in
> ShimmerConnect/BoilerPlate. When you got to Tools->Configure Shimmer you
> will see an option that says "Enable Voltage monitoring". This will change
> the "AnEx ADC0" and AnEx ADC7" channels to "VSenseReg" and "VSenseBatt"
> respectively. Specifically the "SET_PMUX_COMMAND" in BoilerPlate manages
> the state of this mux:
> http://tinyos.cvs.sourceforge.net/viewvc/tinyos/tinyos-2.x-contrib/shimmer/apps/BoilerPlate/Shimmer.h?content-type=text%2Fplain
>
> The part that has not been implemented is to toggle this option quickly in
> order to inter-space voltage monitoring with measuring the external ADC
> channels, or any method to convert the difference between the two voltage
> measurements to instantaneous current (as described in the manual).
>
> Mike
>
>
>
> On Sat, Apr 14, 2012 at 1:48 AM, Nicholas Hosein <[email protected]>wrote:
>
>> Does the boiler plate app have this implemented by chance? or does the
>> shimmer connect software use something besides the boilerplate.
>>
>> Much Thanks,
>>
>> Nick
>>
>>
>> On Fri, Apr 13, 2012 at 1:15 AM, mike healy <[email protected]> wrote:
>>
>>> Hi Nick,
>>>
>>> The battery monitoring is multiplexed with the two ADC channels exposed
>>> on the external connector (i.e. ADC0 and ADC7). So you cannot sample the
>>> battery voltages and these channels at the same time. But you can switch
>>> between the two of them quickly if required.
>>>
>>> See section 2.4.4. of the Shimmer User Manual for further details. See
>>> the FAQ page to see how to convert the raw ADC value you receive back to
>>> battery voltage: http://www.shimmer-research.com/links/faqs#S9.
>>> Remember to double the value due to the halving of the voltage before it is
>>> measured (as mentioned in the referenced section in the manual).
>>>
>>> Mike
>>>
>>> On Wed, Apr 11, 2012 at 7:37 AM, Nicholas Hosein <[email protected]>wrote:
>>>
>>>> I noticed that the shimmer software can access the batter state on the
>>>> mote. In my experience the battery monitor and data bus share the same bus
>>>> so battery updates cannot be made while collecting data (I could be wrong
>>>> about this though). Was there an update to the boiler plate app that allows
>>>> battery monitoring (by percentage or voltage) in realtime while collecting
>>>> data?
>>>>
>>>> Much Thanks,
>>>>
>>>> Nick
>>>>
>>>> _______________________________________________
>>>> Shimmer-users mailing list
>>>> [email protected]
>>>> https://lists.eecs.harvard.edu/mailman/listinfo/shimmer-users
>>>>
>>>>
>>>
>>
>
_______________________________________________
Shimmer-users mailing list
[email protected]
https://lists.eecs.harvard.edu/mailman/listinfo/shimmer-users

Reply via email to