Hi Andrey

I have 16-H2O molecule in my unit cell, i am trying to cool the system
down from 1000K to 300K to be more realistic. The problem still there, the
temperature goes very high and won't stop at the target temperature, i
tried to use annealing, Nose,... all those options give the same problem,
i am wondering if there is any unseen option that can be used to fix this
problem?

yours,
sufain


> Hi Sufian,
>
> How many molecules does your "bunch" contain? It's normal to have
> temperature fluctuations of ~T/sqrt(N), where N is the number of
> particles. Also I encountered non-physical temperature fluctuations
> when initial temperature of run was not equal to final temperature.
> Seems that Nose thermostat in Siesta is not capable to implement
> temperature gradients. And the final remark - if you want to model
> gas-liquid phase transition, Siesta might not be the right tool to do
> it, since it needs a big supercell and large simulation time.
>
> Cheers,
> Andrey.
>
>> Dear Siesta Users
>>
>> I am trying to run a molecular dynamics simulation for a bunch of H2O
>> molecules,i chose the Tini =800 K and Tfin= 300 K  my run starts
>> normally for the first one or two steps. but after that a huge
>> fluctuations in temperature appear, it reached a couple of thousands
>> of kelvins i,tried many options but i still has the same problem,
>> can any body assist me in this problem?
>> Thank you all,
>>
>> sufian
>>
>


Responder a