Hi Andrey

 I have 16-H2O molecule in my unit cell, i am trying to cool the system
 down from 1000K to 300K to be more realistic. The problem still there, the
 temperature goes very high and won't stop at the target temperature, i
 tried to use annealing, Nose,... all those options give the same problem,
 i am wondering if there is any unseen option that can be used to fix this
 problem?

 yours,
 sufain
>
>
>> Hi Sufian,
>>
>> How many molecules does your "bunch" contain? It's normal to have
>> temperature fluctuations of ~T/sqrt(N), where N is the number of
>> particles. Also I encountered non-physical temperature fluctuations
>> when initial temperature of run was not equal to final temperature.
>> Seems that Nose thermostat in Siesta is not capable to implement
>> temperature gradients. And the final remark - if you want to model
>> gas-liquid phase transition, Siesta might not be the right tool to do
>> it, since it needs a big supercell and large simulation time.
>>
>> Cheers,
>> Andrey.
>>
>>> Dear Siesta Users
>>>
>>> I am trying to run a molecular dynamics simulation for a bunch of H2O
>>> molecules,i chose the Tini =800 K and Tfin= 300 K  my run starts
>>> normally for the first one or two steps. but after that a huge
>>> fluctuations in temperature appear, it reached a couple of thousands
>>> of kelvins i,tried many options but i still has the same problem,
>>> can any body assist me in this problem?
>>> Thank you all,
>>>
>>> sufian
>>>
>>
>
>


Responder a