Laurentiu,

Looks good a couple questions/comments:
1. Why would enable log be shown as normal and not advanced?  If someone
disables this do alarms "stop" working? 
2. Not sure that SNMP traps are part of the alarm framework yet. If not
those fields should be removed until they are.
3. Don't think this is "server" code to warrant calling it such. I would
call it just Alarms in the menu.
4. The table under advanced would be good if it can be sorted by click
on header. 

Regards,

Al
-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Laurentiu
Ceausescu
Sent: Monday, August 25, 2008 7:59 AM
To: [EMAIL PROTECTED]
Subject: [sipX-dev] UI proposal for XCF-2692

I attached to the JIRA issue XCF-2692
(http://track.sipfoundry.org/browse/XCF-2692) the UI proposal for this
feature.
Please comment.

Regards,
Laurentiu