Ranga wrote: > The current GUI implicitly supposes a 1-1 mapping between > ITSP and gateway. What we need is a many to one mapping from > gateway to ITSP account.
Why is the 1-1 mapping bad? In most cases the mapping is 1-1. In the few cases it isn't 1-1, then the admin needs to enter the same ITSP credentials a couple of extra times. Minor inconvenience. On the other hand, introducing the notion of an ITSP Account that must be independently created/configured, and then linked back to a Gateway instance... That's a lot of complexity to add for minimal benefit in a minority of scenarios. > Also, you can enter identical ITSP information twice in the > GUI in which case you get two records in sipxbridge.xml > which are identical except for the line ID. This is unacceptable. Yes. The sipxbridge.xml generation problem should be fixed. That's the root problem behind XX-4785 right? If the current UI somehow prevents this fix, then please explain how. Thanks. -Paul [email protected] _______________________________________________ sipx-dev mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-dev Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-dev sipXecs IP PBX -- http://www.sipfoundry.org/