I am using SipXecs 4.0.1. I already disabled all the settings in my X-Lite softphone as described in the document. But it seemed the settings did not work until complete restart of X-Lite. Now everything works fine.
2009/7/9 Tony Graziano <[email protected]> > What kind of phone are you using remotely? What kind of firewall? > A lot of consumer firewalls need to have the ALG (Application Layer > Gateway) for SIP turned off, though you may have to dig through the advanced > settings to find it. If your remote phone is a softphone, you should make > sure you have all the settings (local address/disable ice) configured as > described below.. > > What version of sipxecs do you have installed? > > >>> Rene Pankratz <[email protected]> 07/09/09 5:10 AM >>> > Thanks for your answer, i only set up the settings you described und went > on > the steps. > There were only left the loopback and th local subnet the SipX and the > phones are in in the internet calling settings. > > But still there is the voice related problem. > When calling an internal phone the remote worker's phone is sent sdp with > the internal address (behind NAT) of the called phone. So there is no way > getting RTP into the office. > > René > > 2009/7/9 Tony Graziano <[email protected]> > > > I think you are misinterpreting the instructions. > > On that page you simply define your local routed subnets. > > Internet calling does not factor for remote worker setup except to define > > your internal subnets so that your system knows to accept those calls > > instead of rejecting them for lack of authentication via the proxy. > Define > > your subnets (not the one your remote worker is on since it is not > privately > > routed) and go to the next step. > > > > >>> Rene Pankratz <[email protected]> 07/09/09 4:11 AM >>> > > Hallo, > > after successfully configuring a SIP Trunk with bluesip I wanted to add > > support for remote workers on my SipX-installation (4.0.1-015823). > > > > I wanted to configure remote workers as described here: > > > > > http://sipx-wiki.calivia.com/index.php/Configuring_remote_workers_cheatsheet > > > > But when I navigate to System->Internet Calling I cannot select the SBC > > that > > is already configured for SIP Trunk. > > > > How can I select the existing or configure another internal SBC für > > handling > > remote workers? > > > > At this point remote clients can register, but RTP is handled incorrect > as > > the SDP part shows the internal IPs of the phones in SipX's internal > > network. > > > > Thanks in advance > > René > > </[email protected]> > > > </[email protected]></[email protected]> >
_______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users sipXecs IP PBX -- http://www.sipfoundry.org/