On 4.0.4 at least

and not managed by sipX

Josh Patten
Assistant Network Administrator
Brazos County IT Dept.
(979) 361-4676


On 5/14/2010 5:07 PM, Josh Patten wrote:
> I run 5.8 on my mediant 1000 with no problems.
>
> Josh Patten
> Assistant Network Administrator
> Brazos County IT Dept.
> (979) 361-4676
>
>
> On 5/14/2010 5:07 PM, Tony Graziano wrote:
>    
>> 5.6 good. 5.8 bad.
>>
>> I didn't know anyone ran 5.8 with sipx with huge success. Weren't there
>> tracker items on that?
>> ============================
>> Tony Graziano, Manager
>> Telephone: 434.984.8430
>> Fax: 434.984.8431
>>
>> Email: [email protected]
>>
>> LAN/Telephony/Security and Control Systems Helpdesk:
>> Telephone: 434.984.8426
>> Fax: 434.984.8427
>>
>> Helpdesk Contract Customers:
>> http://www.myitdepartment.net/gethelp/
>>
>> ----- Original Message -----
>> From: [email protected]
>> <[email protected]>
>> To: Josh Patten<[email protected]>
>> Cc: [email protected]<[email protected]>
>> Sent: Fri May 14 17:46:00 2010
>> Subject: Re: [sipx-users] sipXecs 4.2 voicemail allows only 10 seconds of
>> recording before disconnecting
>>
>> On 10-05-14 9:25 AM, Josh Patten wrote:
>>
>>      
>>> Did you ever find a fix to this? I'm curious if so because I will be
>>> updating to 4.2 tonight (I use audiocodes gateways)
>>> and I was hoping I would be able to fix this before it was ever a problem.
>>>
>>>        
>> I now see the following errors.
>> After 10 seconds, the AudioCodes is reporting:
>>
>> FXO Release Line
>> Guard_Time_Timer_Expired_EV
>>
>> On my second test, I saw this:
>>
>> RELEASE_BECAUSE_IP_TIMER_EXPIRED_EV
>>
>> Since I didn't want to take the chance of upgrading the firmware on my
>> AudioCodes MP-118 FXO
>> from 5.2 to 5.6 without a fallback, I configured a gateway account for
>> VOIP.MS on Monday.
>> I couldn't get the account to register and haven't had a chance to
>> report the details yet.
>>
>> This morning we had a "power event" and one of my 2 6KVA UPS had bad
>> batteries
>> so half my servers shut down (all the ones with a single power supply
>> plugged into the bad UPS).
>> When the AudioCodes came back up, the boss placed an outbound call to
>> Houston for a conference
>> attendee who couldn't call in. They used this line for about 2 hours.
>>
>> When the conference ended, I power cycled the AudioCodes, and lost all
>> contact with it.
>> I took it to my supplier who recovered the device by installing the 5.8
>> firmware.
>> My original configuration was intact. I realized why it stopped
>> functioning -
>> it was configured ith the IP addresses of my backup sipXecs server. I
>> hadn't burned the flash
>> after cutting over to my new sipXecs 4.2 server.
>>
>> So I have a PSTN connection again.
>> Voicemail still disconnects after 10 seconds.
>> I made the following 2 changes to look like the configuration defaults
>> in sipXecs for AudioCodes:
>> Subscription Mode and Authentication Mode - changed "per Endpoint" to
>> "per Gateway"
>> Alas, to no avail.
>>
>>
>>      
> _______________________________________________
> sipx-users mailing list [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipx-users
> Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
> sipXecs IP PBX -- http://www.sipfoundry.org/
>    
_______________________________________________
sipx-users mailing list [email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users
Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
sipXecs IP PBX -- http://www.sipfoundry.org/

Reply via email to