Maybe I don't understand the question. If a 407 proxy authentication is being received, it would make sense to me that the proxy is being challenged by something.
The site A gateways would need to be set up by the site B proxy and the dial plan as an unmanaged gateway. The gateway needs to be told to accept calls FROM SITE B's network (not just the proxy, but the phones too). Usually this is done in an ACL. Site A's proxy should not be involved in the transaction, but it would require the gateway knows how to route back. Since is is giving a 407 back to SITE B's proxy, I would assume it knows but realizes it is off its network and simply needs to challenge it because it has not been told to implicitly trust it (via an ACL mechanism on the gateway). I might also be daft, as I'm not totally in tune with AC gear, but they all seem to work somewhat the same. my 2 cents. On Sun, Jun 12, 2011 at 1:00 PM, Michael Picher <[email protected]> wrote: > See in-line... > > On Sun, Jun 12, 2011 at 12:49 PM, Dragan Jurkovic <[email protected]> > wrote: >> >> Hi, >> >> I have two sites connected via VPN and site-to-site >> gateways/dialplan. Site to site dialing works like a charm. Both sites >> have Audiocodes gateways (Mediant 1000PRI and MP118 FXO on other site) >> as gateways to PSTN. I am wondering is it possible to use remote >> site's gateway to place long distance calls? For example can I define >> remote gateway on local site and create dial plan which will use that >> gateway? > > This should work as long as the gateway knows how to route back to you... > Try to ping it to verify... > >> >> What I tried is to define a gateway (as an unmanaged one >> pointing to the remote Mediant one) and then created dial plan as >> prefix 1NNN and 7 digits to dial out as NNN and dialed 7 digits using >> defined gateway but I am getting fast busy signal. Sipviewer shows 407 >> registration requests coming from remote site. This happens if I try >> to use either remote Mediant or site-to-site gateway. I even tried to >> define same user on remote site but no avail. >> Has anyone ever tried this? >> >> Thank you in advance, >> Dragan >> _______________________________________________ >> sipx-users mailing list >> [email protected] >> List Archive: http://list.sipfoundry.org/archive/sipx-users/ > > > > -- > Michael Picher > eZuce > Director of Technical Services > O.978-296-1005 X2015 > M.207-956-0262 > @mpicher <http://twitter.com/mpicher> > www.ezuce.com > > > _______________________________________________ > sipx-users mailing list > [email protected] > List Archive: http://list.sipfoundry.org/archive/sipx-users/ > -- ====================== Tony Graziano, Manager Telephone: 434.984.8430 sip: [email protected] Fax: 434.326.5325 Email: [email protected] LAN/Telephony/Security and Control Systems Helpdesk: Telephone: 434.984.8426 sip: [email protected] Helpdesk Contract Customers: http://support.myitdepartment.net Blog: http://blog.myitdepartment.net Linked-In Profile: http://www.linkedin.com/pub/tony-graziano/14/4a6/7a4 _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/