Thanks all.  On to 4.4…

Jeff
On Aug 4, 2011, at 6:28 PM, Michael Picher wrote:

> You whacky developers with your tricky naming schemes...
> 
> On Aug 4, 2011 6:20 PM, "George Niculae" <[email protected]> wrote:
> > On Fri, Aug 5, 2011 at 1:17 AM, Michael Picher <[email protected]> wrote:
> >> Looks like it may have been back-ported to 4.2.1 but I don't think a new
> >> build has been cranked for 4.2.1.
> >> Mike
> >>
> > 
> > Actually was not backported, read master-4.2 as release-4.6. For
> > sipxecs 4.2.1 there is release-4.2
> > 
> > George
> > 
> >> On Thu, Aug 4, 2011 at 6:14 PM, Tony Graziano 
> >> <[email protected]>
> >> wrote:
> >>>
> >>> I'm mighty certain it is:
> >>> http://track.sipfoundry.org/browse/XX-9699
> >>> If so, no amount of staring at it will fix it for you in 4.2.
> >>>
> >>> On Thu, Aug 4, 2011 at 6:11 PM, Jeff Gilmore <[email protected]> wrote:
> >>>>
> >>>> Thanks Josh.  Not sure that applies, though, since I am not running a 4.4
> >>>> version and that looked like a new bug in 4.4.  I will eventually update 
> >>>> to
> >>>> 4.4, but I have had so much user downtime lately due to ITSP issues, 
> >>>> that I
> >>>> just can't face it!
> >>>> The behavior on the Polycom looks like what happens when a second call
> >>>> comes in when you are already on the line, but of course, there is only 
> >>>> the
> >>>> one call.
> >>>> Anyone interested in looking at a trace?
> >>>> Thanks,
> >>>> Jeff
> >>>> On Aug 4, 2011, at 3:32 PM, Josh Patten wrote:
> >>>>
> >>>> This may be related to a bug regarding PRACK:
> >>>> http://track.sipfoundry.org/browse/XX-9699
> >>>>
> >>>> the only suggestion I have at this point is to upgrade to the latest 4.4
> >>>> release
> >>>>
> >>>>
> >>>> On Thu, Aug 4, 2011 at 1:05 PM, Jeff Gilmore <[email protected]>
> >>>> wrote:
> >>>>>
> >>>>> I have a problem that has cropped up recently.  My extensions are mostly
> >>>>> served by SPA2102 ATA devices, but on a particular extension, I have 
> >>>>> both a
> >>>>> Polycom IP320 and an SPA2102 ATA registered.  Until recently, it worked
> >>>>> great and I could pick up incoming calls on either one.
> >>>>>
> >>>>> Now, if I receive an incoming call and try to pick it up on the Polycom,
> >>>>> it seems to grab the call, but the phone displays 
> >>>>> <answer><ignore><more> ,
> >>>>> and pressing answer does not pick up the call.  The call stops ringing, 
> >>>>> but
> >>>>> I get dead air on the Polycom.  It used to just pick up.  The SPA2102 
> >>>>> picks
> >>>>> up calls just fine.
> >>>>>
> >>>>> This only happens with calls that come through my ITSP--local calls work
> >>>>> fine.  On these outside calls, on the caller's phone, it stops giving a 
> >>>>> ring
> >>>>> tone and acts like it has been picked up, but they get dead air.  I see 
> >>>>> the
> >>>>> callerID of the caller appear on the Polycom.
> >>>>>
> >>>>> There were some recent changes caused by problems on my ITSP's side.
> >>>>>  They moved my account to a new proxy  server and a new SBC, so I had to
> >>>>> change the IP address in my Sipx gateway configuration.  I am running
> >>>>> Polycom 3.1.3.0439 firmware, but that has not changed.  I am running 
> >>>>> sipx
> >>>>> 4.2.1.
> >>>>>
> >>>>> Any suggestions of what might be wrong?  I have traces of both a
> >>>>> (failed) Polycom call and a (successful) SPA2102 call if you are 
> >>>>> willing to
> >>>>> take a look at them.
> >>>>>
> >>>>> Thanks!
> >>>>>
> >>>>> Jeff
> >>>>> _______________________________________________
> >>>>> sipx-users mailing list
> >>>>> [email protected]
> >>>>> List Archive: http://list.sipfoundry.org/archive/sipx-users/
> >>>>
> >>>>
> >>>>
> >>>> --
> >>>> Josh Patten
> >>>> eZuce
> >>>> Solutions Architect
> >>>> O.978-296-1005 X2050
> >>>> M.979-574-5699
> >>>> _______________________________________________
> >>>> sipx-users mailing list
> >>>> [email protected]
> >>>> List Archive: http://list.sipfoundry.org/archive/sipx-users/
> >>>>
> >>>> _______________________________________________
> >>>> sipx-users mailing list
> >>>> [email protected]
> >>>> List Archive: http://list.sipfoundry.org/archive/sipx-users/
> >>>
> >>>
> >>>
> >>> --
> >>> ======================
> >>> Tony Graziano, Manager
> >>> Telephone: 434.984.8430
> >>> sip: [email protected]
> >>> Fax: 434.326.5325
> >>>
> >>> Email: [email protected]
> >>>
> >>> LAN/Telephony/Security and Control Systems Helpdesk:
> >>> Telephone: 434.984.8426
> >>> sip: [email protected]
> >>>
> >>> Helpdesk Contract Customers:
> >>> http://support.myitdepartment.net
> >>> Blog:
> >>> http://blog.myitdepartment.net
> >>>
> >>> Linked-In Profile: http://www.linkedin.com/pub/tony-graziano/14/4a6/7a4
> >>> Ask about our voip fax services!
> >>>
> >>> _______________________________________________
> >>> sipx-users mailing list
> >>> [email protected]
> >>> List Archive: http://list.sipfoundry.org/archive/sipx-users/
> >>
> >>
> >>
> >> --
> >> Michael Picher
> >> eZuce
> >> Director of Technical Services
> >> O.978-296-1005 X2015
> >> M.207-956-0262
> >> @mpicher <http://twitter.com/mpicher>
> >> www.ezuce.com
> >>
> >>
> >> _______________________________________________
> >> sipx-users mailing list
> >> [email protected]
> >> List Archive: http://list.sipfoundry.org/archive/sipx-users/
> >>
> > _______________________________________________
> > sipx-users mailing list
> > [email protected]
> > List Archive: http://list.sipfoundry.org/archive/sipx-users/
> _______________________________________________
> sipx-users mailing list
> [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipx-users/

_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to