Actually it is...
Itsp--->patton 4960 ---> nec pbx
---> sipx
On Nov 20, 2011 2:55 PM, "Todd Hodgen" <[email protected]> wrote:
> Example being used by a customer today - sipXecs ------> Ethernet
> ------>
> Audiocodes M1000 ------> PRI -------> Nortel CS1k
>
> Works great.
>
> I believe I've seen others describe sipXecs -------> Ethernet -------->
> Patton 4960 --------> PRI --------> NEC PBX.
>
> -----Original Message-----
> From: [email protected]
> [mailto:[email protected]] On Behalf Of
> [email protected]
> Sent: Sunday, November 20, 2011 8:28 AM
> To: sipx-users
> Subject: Re: [sipx-users] SIP Hunt Group
>
> > You can use an audiocodes gateway or a Patton Gateway for that
> > functionality.
> >
> > SIP to the Audiocodes/Patton then PRI to the Legacy PBX. It's done
> > all the time, and provides a migration strategy.
>
> I'm guessing a certain model then, not the 1K or 2K models right? I've
> never
> come across information of that sort.
> Good to hear that indeed there are devices that will take a SIP trunk then
> provide a PBS it's lines via PRI.
>
> I recall asking once if my 2K's could handle SIP trunks, I seem to recall
> being told no.
> I'll look into the patton as well though I am more familiar with the
> audiocodes now.
>
> _______________________________________________
> sipx-users mailing list
> [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipx-users/
>
> _______________________________________________
> sipx-users mailing list
> [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipx-users/
>
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/