Are you on the most current release of 4.4?

This was a problem with older releases of 4.4.  Once you install from ISO
you must 'yum update'.

Thanks,
  Mike

On Tue, Apr 24, 2012 at 6:07 AM, Marand Remi <[email protected]> wrote:

> **
>
> Hello,****
>
> ** **
>
> I am trying to route calls from one gateway to another one, both connected
> to sipX.****
>
> ** **
>
> I have tried a lot of combination, 2 sip trunks, 2 unmanaged gateways, 1T
> and 1unmanagedGW an so.****
>
> ** **
>
> I have studied the "DNS" point of view and i am sure that sipX can resolve
> pertinent DNS records for each gateway other's domain. ("A" records in the
> local /var/named/*.zone files, nslookup and ping on domain’s name and on
> proxies URI”s are OK.****
>
> ** **
>
> I have tried a lot of dial plans, site to site (with domain name instead
> of proxies name), custom dial plan, etc...****
>
> ** **
>
> The issue is always the same, the response to external incoming invite is
> "407 Authentication required", it is not possible to have authentication
> here, because the From: URI is unknown in the sipX, and the To: URI is
> sip:[email protected] where number is not a known user in the
> registrar DB.****
>
> ** **
>
> I can make this working by "indirect" route, via a call forward from a
> phantom user (in this case, number is an alias of this user).. but it is
> not that i want.****
>
> ** **
>
> 2 Questions :****
>
> 1) What is the way to debug the dial plan processing ?? There is
> informations in sipXproxy.log, sipregistrar.log, sipxbridge.log,
> sipxrelay.log but it is difficult to know if the routing process is
> considering dial plan or not. ****
>
> My sensation is that external incoming call (from ITSP or Gateway) is not
> possible to route to another thing but local user.****
>
> ** **
>
> 2) What is your advice to obtain an external to external routing ?? I know
> that it is not the first job to obtain from sipX, but i am searching to not
> install another SIP Proxy.****
>
> ** **
>
> Best Regards.****
>
> ** **
>
> **Rémi Marand** - Directeur d'études / R&D Project Manager.****
>
> ---------------------------------------------------****
>
> PROSODIE - Direction de l'ingénierie de production.****
>
> Tél. : +33 (0)1 46 84 12 77/ Mob. : +33 (0)6 87 72 53 25****
>
> Fax : +33 (0)1 41 10 94 94****
>
> e-mail : [email protected]****
>
> ---------------------------------------------------****
>
> www.prosodie.com****
>
> ** **
>
> ** **
>
> _______________________________________________
> sipx-users mailing list
> [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipx-users/
>



-- 
Michael Picher, Director of Technical Services
eZuce, Inc.

300 Brickstone Square****

Suite 201****

Andover, MA. 01810
O.978-296-1005 X2015
M.207-956-0262
@mpicher <http://twitter.com/mpicher>
www.ezuce.com

------------------------------------------------------------------------------------------------------------
There are 10 kinds of people in the world, those who understand binary and
those who don't.
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to