Wolf wrote:
> Hi,
>
>
> In attachment there is result of smartctl with -r ioctl,2
>
> Hope this help.
>

Thanks.

> 177 Wear_Leveling_Count     0x0000   000   000   ---    Old_age   Offline     
>  -       0
> 177 Wear_Leveling_Count<== Data Page      |  WARNING: PREVIOUS ATTRIBUTE HAS 
> TWO
> 181 Program_Fail_Cnt_Total<== Threshold Page |  INCONSISTENT IDENTITIES IN 
> THE DATA
> 181 Program_Fail_Cnt_Total  0x0000   000   000   ---    Old_age   Offline     
>  -       0
>    

These messages appear because the entry for attribute 177 is missing in 
the threshold table returned by the drive.

I added a workaround to smartctl (SVN r3132) to avoid this message and 
print the remaining thresholds properly.
Other features (e.g. new format of Power_On_Hours) will be added soon.

Thanks,
Christian


------------------------------------------------------------------------------