I see someone submitted this same bug about 3 days ago: http://bugs.opensolaris.org/bugdatabase/view_bug.do?bug_id=6658565
Can anyone comment on whether disabling intrd is a safe workaround until the bug is fixed in future SXCE releases? What else might disabling intrd adversely affect? I'm dead in the water until I can either workaround or have a fix. Please advise. -- Dave On 02/06/2008 02:15 PM, Dave wrote: > I've got a number of machines running nv_b81 and I'm getting messages > like this: > > WARNING: /[EMAIL PROTECTED],0/pci10de,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 > (sd0): > Error for Command: read(10) Error Level: Retryable > Requested Block: 10089026 Error Block: 10089026 > Vendor: ATA Serial Number: > > Sense Key: No_Additional_Sense > ASC: 0x0 (no additional sense info), ASCQ: 0x0, FRU: 0x0 > NOTICE: /[EMAIL PROTECTED],0/pci10de,[EMAIL PROTECTED]: > port 0: device reset > > I'm unable to use the machines after I get the warning - they must be > hard rebooted. I've tried disabling NCQ in /etc/system without success. > This has happened in prior versions of Nevada as well. I usually get the > message when first booting, but not always. > > All machines are running Dual Proc Opteron 2214, Tyan 2927G2NR > motherboard, WD 500GB SATA drives. > > I'm at my wits end trying to find the solution. Any help is appreciated. > > Thanks > -- > Dave > _______________________________________________ > storage-discuss mailing list > [email protected] > http://mail.opensolaris.org/mailman/listinfo/storage-discuss _______________________________________________ storage-discuss mailing list [email protected] http://mail.opensolaris.org/mailman/listinfo/storage-discuss