I see someone submitted this same bug about 3 days ago:

http://bugs.opensolaris.org/bugdatabase/view_bug.do?bug_id=6658565

Can anyone comment on whether disabling intrd is a safe workaround until 
the bug is fixed in future SXCE releases? What else might disabling 
intrd adversely affect?

I'm dead in the water until I can either workaround or have a fix. 
Please advise.

--
Dave

On 02/06/2008 02:15 PM, Dave wrote:
> I've got a number of machines running nv_b81 and I'm getting messages 
> like this:
> 
> WARNING: /[EMAIL PROTECTED],0/pci10de,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 
> (sd0):
>          Error for Command: read(10)                Error Level: Retryable
>          Requested Block: 10089026                  Error Block: 10089026
>          Vendor: ATA                                Serial Number: 
> 
>          Sense Key: No_Additional_Sense
>          ASC: 0x0 (no additional sense info), ASCQ: 0x0, FRU: 0x0
> NOTICE: /[EMAIL PROTECTED],0/pci10de,[EMAIL PROTECTED]:
>   port 0: device reset
> 
> I'm unable to use the machines after I get the warning - they must be 
> hard rebooted. I've tried disabling NCQ in /etc/system without success. 
> This has happened in prior versions of Nevada as well. I usually get the 
> message when first booting, but not always.
> 
> All machines are running Dual Proc Opteron 2214, Tyan 2927G2NR 
> motherboard, WD 500GB SATA drives.
> 
> I'm at my wits end trying to find the solution. Any help is appreciated.
> 
> Thanks
> --
> Dave
> _______________________________________________
> storage-discuss mailing list
> [email protected]
> http://mail.opensolaris.org/mailman/listinfo/storage-discuss
_______________________________________________
storage-discuss mailing list
[email protected]
http://mail.opensolaris.org/mailman/listinfo/storage-discuss

Reply via email to