On Wed, 6 Feb 2008, Dave wrote:

> I've got a number of machines running nv_b81 and I'm getting messages
> like this:
>
> WARNING: /[EMAIL PROTECTED],0/pci10de,[EMAIL PROTECTED]/[EMAIL PROTECTED],0 
> (sd0):
>         Error for Command: read(10)                Error Level: Retryable
>         Requested Block: 10089026                  Error Block: 10089026
>         Vendor: ATA                                Serial Number:
>
>         Sense Key: No_Additional_Sense
>         ASC: 0x0 (no additional sense info), ASCQ: 0x0, FRU: 0x0
> NOTICE: /[EMAIL PROTECTED],0/pci10de,[EMAIL PROTECTED]:
>  port 0: device reset
>
> I'm unable to use the machines after I get the warning - they must be
> hard rebooted. I've tried disabling NCQ in /etc/system without success.
> This has happened in prior versions of Nevada as well. I usually get the
> message when first booting, but not always.
>
> All machines are running Dual Proc Opteron 2214, Tyan 2927G2NR
> motherboard, WD 500GB SATA drives.
>
> I'm at my wits end trying to find the solution. Any help is appreciated.

Would installing a SuperMicro AOC-SAT2-MV8 PCI-X resolve this issue 
(for now)?

Regards,

Al Hopper  Logical Approach Inc, Plano, TX.  [EMAIL PROTECTED]