kristof wrote: > Does anyone knows why Comstar is not answering the Read Capacity(10) request > ??? > > Why is it sending a Check Condition reply? > > Kristof >
From the trace the initiator logged into the target then immediately sends a read capacity command. The first command completes with a check condition "Report Luns Data Has Changed". The initiator immediately retries the read capacity command which completes with a different check condition "Invalid Command Operation Code". Since "read capacity" is clearly a valid operation code, it would appear that there is no sbd lun mapped to lun 0 on that port. In other words the view entries are probably not quite right. The trace is a bit strange -- one would normally expect to see some preliminary commands like "inquiry" and "report luns" before jumping straight to "read capacity". -Peter _______________________________________________ storage-discuss mailing list [email protected] http://mail.opensolaris.org/mailman/listinfo/storage-discuss