On Wed, Jun 04, 2014 at 07:45:18AM +0200, Joakim Bygdell wrote: > >> Planner: > >> 1# Unused gas mixes are not shown even if the option is set in preferences. > > > > Yes, I thought that was the consensus when we discussed this earlier. I no > > longer copy unused cylinders. > > We did, yet something is not right.
Correct. Because we did it wrong. Duh. Should be fixed in the latest master. > >> 2# Unused gas mixes are still used in the planned dive resulting in zero > >> consumption issues and extra gas switch events. > > > > That sounds wrong. I don't see how this could be happening. > > > > Can you send step by step instructions how to reproduce this? > > Select dive with unused gases. > Start Planner. > In my case I had AIR as last active gas and a couple of mixes as unused gases. > > The planner then sets a gas switch at 15min. > And I have al list of gases in the dive plan details that have zero > consumption. > Dirk, this is tested on the dive that I sent earlier. Please try again. > Another thing on master is that in Divelist the displayed gas is not the > active gas. > > I will dig into this a bit more. Yes please - and try to explain it better as I'm not sure I understand what you mean. /D _______________________________________________ subsurface mailing list [email protected] http://lists.hohndel.org/cgi-bin/mailman/listinfo/subsurface