Forgot to send a copy back to the mailing-list:
> I found that next values are: SENSOR_PHASE - 0x9 > MULTI_PHASE1 - 0x100b0. > 1. I don't know. With SENSOR_PHASE unchanged try several points within each quarter for MULTI_PHASE1, e.g.: 0x8ff70, 0x80000, 0x80070, 0x9ff70, ... 0xaff70, ... 0xbff70, 0xb0000, 0xb0070. Sometimes a phase shifter (digital clock manager in the fpga) can get stuck - so it's safer to set 15th bit to 1 to reset it. You can try with a 450mm cable if the long one can be easily disassembled. 2. How exactly do you connect 2 cables? picture? Any difference in the voltage levels on the ends between 450mm and 900mm setups? 3. If both images are broken in the same manner then try to change the SENSOR_PHASE. Best regards, Oleg Dzhimiev Electronics Engineer phone: +1 801 783 5555 x124 Elphel, Inc.
_______________________________________________ Support-list mailing list Support-list@support.elphel.com http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com