What's the exact error when the machine doesn't come up again after failure? I usually just power down my testmachines by unplugging the psu just to see how it will survive such a condition and I never had such a breakdown yet. You mention CARP? So there is a second machine? Or are you only using the CARP as VIP for the one machine? In case you have a CARP-cluster and sync over the config.xml make sure you don't have build a syncing loop. This way the config.xml is moved from master to backup to master to backup... and it's most likely that you hit a write cycle of the config.xml then when the poweroutage appears. This will end up in a broken config file.
Holger > -----Original Message----- > From: Lee Hetherington [mailto:[EMAIL PROTECTED] > Sent: Tuesday, June 27, 2006 11:22 AM > To: [email protected] > Subject: [pfSense Support] PFSense + Poweredge > > > Hi Guys, > > Im having issues with my current PFSense box in that > everytime the power > is lost (Our Colo provider had a poweroutage last week) > PFSense needs to > be re-installed to work. The latest one meant I had to drive > 200 miles > in order to fix it. > > Is there anything I can do to stop this happening other than > putting a > UPS onto the machine (Its a Poweredge 1850, 2.8Ghz Xeon, 1Gb > Ram, Single > 72Gb SCSI Disk). This time the machine booted, but I couldnt ping > anything from it nor ping the machine (It did hang for a > while bringing > up CARP interfaces). > > Im tempted to buy 2x Poweredge 850's with SATA, are their any known > issues installing onto this, im not sure if SATA on these is > supported > under FreeBSD... > > Cheers for the heads up > > Lee > > > --------------------------------------------------------------------- > To unsubscribe, e-mail: [EMAIL PROTECTED] > For additional commands, e-mail: [EMAIL PROTECTED] > > ____________ Virus checked by G DATA AntiVirusKit --------------------------------------------------------------------- To unsubscribe, e-mail: [EMAIL PROTECTED] For additional commands, e-mail: [EMAIL PROTECTED]