> Bruce, > > Thanks for the tip. I was very careful. Only one board was really > stuck. I left it alone for now. > > Just for the heck of it, I did a few more steps in the Chapter 4 > Operation Verification. As I said, discounting the bad BNC, step 13 > reads aproximately 103.6nS, so I continued. > > Steps 14, 15 and 16 are ok. > > Step 17 shows 3.6nS (should be < 1nS). Period Compliment shows > -96.3nS. Something very wrong here.
What are your trigger levels? A small departure from 0.00 volts could account for this. Also, what's the standard deviation when measuring its own OCXO? -- john, KE5FX _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.