Replace the 10 mHz oscillator with a divide by ten counter
driven by the 100 mHz signal. Connect the control voltage
from the Tbolt to the 100 mHz oscillator through a low pass
filter and voltage divider that provides the minimum signal
required for discipline. Tboltmon can set gain etc., even invert the
signal.
--
Chuck Forsberg WA7KGX N2469R [email protected] www.omen.com
Developer of Industrial ZMODEM(Tm) for Embedded Applications
Omen Technology Inc "The High Reliability Software"
10255 NW Old Cornelius Pass Portland OR 97231 503-614-0430