On 08/31/2013 02:31 AM, Bob Camp wrote: > Hi > > Convergence in a PLL has no absolute definition. In some cases 45 degree > phase error = all is running fine. > > I would simply track GPS time vs OCXO time and declare it ok when it's inside > some magic number of nanoseconds. Exactly my thoughts. If you have sawtooth errors, then you need to look at the average or possibly mid-point between latest min and latest max of the phase-detector.
Cheers, Magnus _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.