Attila wrote:
Yes, depending on the data you show, it is not clear whether one should do a linear or a logarithmic fit.
When the purpose is correcting a GPSDO local oscillator during holdover, it depends on how long one expects to trust the corrected frequency. Practical realities make it pointless to trust corrections longer than a day or so, if that long. At that scale, these all look pretty linear.
NB: That may *not* be the case for a TCXO, or a crappy OCXO. But then, it would probably be pointless to correct these for longer than an hour or so, at which scale they also may look linear.
Best regards, Charles _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.