Glen: Are you logging the UniObjects connection? This may give you some additional information (it usually does for me). To do so you should create a file in the "ud71" directory named "serverdebug". I put the following line in mine: udcs 9 E:\IBM\ud71\log\udcs\udcs.log As you can see, the output goes to a new directory, "...\ud71\logs\udcs". To turn logging off change "9" to "0" (no quotes). HTH, Bill
-----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Glenn Batson Sent: 22 April 2009 02:17 To: [email protected] Subject: [U2] Need assistance replicating UniObjects.NET issue Does anyone have any insight into how to create the following error. Error Message: IBMU2.UODOTNET.UniXMLException: Unable to read data from the transport connection: An existing connection was forcibly closed by the re host.[IBM U2][UODOTNET - UNIRPC][ErrorCode=81009] The RPC failed[IBM U2][UODOTNET - UNICLIENT][ErrorCode=91] Please verify UniVerse or UniData Version. This feature may not be supported in older UniVerse or Unidata version. UNIDATA 7.1.0 Windows 2003 I've tried killing the udapislave.exe process associated with the connection and then accessing the connection. I get a similar error but not this one. I've tried to sleep to long but noticed I we don't set the timeout property on the UniObject and the default is no timeout. So it just sits there waiting. I haven't tried unplugging the network cable yet or mimicking some network interruption. Any ideas would be greatly appreciated. Thanks, Glenn ------- u2-users mailing list [email protected] To unsubscribe please visit http://listserver.u2ug.org/
