Glen:
   Are  you  logging  the  UniObjects connection?  This may give you some
   additional information (it usually does for me).  To do so you should create
   a file in the "ud71" directory named "serverdebug".  I put the following
   line in mine:
   udcs 9 E:\IBM\ud71\log\udcs\udcs.log
   As you can see, the output goes to a new directory, "...\ud71\logs\udcs".
   To turn logging off change "9" to "0" (no quotes).
   HTH,
   Bill

-----Original Message-----
From: [email protected]
[mailto:[email protected]] On Behalf Of Glenn Batson
Sent: 22 April 2009 02:17
To: [email protected]
Subject: [U2] Need assistance replicating UniObjects.NET issue

Does anyone have any insight into how to create the following error.

Error Message: IBMU2.UODOTNET.UniXMLException: Unable to read data
from the transport connection: An existing connection was forcibly
closed by the re host.[IBM U2][UODOTNET - UNIRPC][ErrorCode=81009]
The RPC failed[IBM U2][UODOTNET - UNICLIENT][ErrorCode=91]  Please
verify UniVerse or UniData Version. This feature may not be supported
in older UniVerse or Unidata version.

 UNIDATA 7.1.0

 Windows 2003

I've tried killing the udapislave.exe process associated with the
connection and then accessing the connection.  I get a similar error but
not this one.  I've tried to sleep to long but noticed I we don't set
the timeout property on the UniObject and the default is no timeout.  So
it just sits there waiting.  I haven't tried unplugging the network
cable yet or mimicking some network interruption.

Any ideas would be greatly appreciated.

Thanks,

Glenn
-------