----- Original Message -----
Sent: Thursday, February 05, 2004 1:48
AM
Subject: RE: Migrating U2 data
WRONG WRONG WRONG !!!
Sorry for shouting here, but I noticed the OP said he was
currently running UV/SCO, and wanted to switch to UV/NT.
So, with the very important caveat that "can UV 10 cope
with UV 7 data?", all he needs do is an os-level copy of the data file from
one system to the other. It REALLY IS that simple. I'm running UV9/NT,
UV9/SCO, and UV10/linux. *ALL* the data files are binary compatible across all
three systems!
Couple of notes for the OP (and others
:-)
1) OP is short for "original poster"
2) fnuxi is for converting between endian-ness. You do
not need it when moving between processors that are the same endian, so going
from SCO (intel) to NT (intel) is fine. The OS is irrelevant as to whether you
need fnuxi. You would need fnuxi to go between UV/linux and UV/linux if one
was on Intel and the other on z800/power.
3) UniData and UniVerse are two different products made
(originally) by two different companies. The OP only has UV so UD is
irrelevant here :-)
Cheers,
Wol
I
have done this a number of times and all I did was use the fnuxi command in
uv/bin directory.
(1)
Copy Unix accounts to the windows server.
(2)
Enter following command in the directory containing the unix data at the
Windows command prompt:
dir/b | fnuxi
This lists each file name and passes it to the fnuxi command to
convert to the correct format for the Windows platform.
Alan Bateman
EVOLUTION Software Services
Pty Ltd
solutions for changing needs
4-10 Bridge Street
PYMBLE NSW 2073
Phone : (02) 9497
4340
Mobile : (0417) 685 246
Fax : (02) 9497 4370
E-mail : abateman@evoss.com.au
Web
: www.evoss.com.au
The information contained in this e-mail is intended only for the named
recipient(s) and may be confidential and/or privileged.Unauthorised use or reproduction (including storage or re-distribution)
is prohibited. Except as required at law, Evolution Software Services Pty Ltd does not represent, warrant and/or guarantee
that the integrity of this communication has been
maintained nor that the communication is free of errors, virus, interception
or interference.
Any pointers on what document explains how to
move data from an old old UNIX U2 system to a new 10.0 Windows
system?
Thanks.
Cyndi
***********************************************************************************
This
transmission is intended for the named recipient only. It may contain private
and confidential information. If this has come to you in error you must not
act on anything disclosed in it, nor must you copy it, modify it, disseminate
it in any way, or show it to anyone. Please e-mail the sender to inform us of
the transmission error or telephone ECA International immediately and delete
the e-mail from your information system.
Telephone numbers for ECA
International offices are: Sydney +61 (0)2 9911 7799, Hong Kong + 852 2121
2388, London +44 (0)20 7351 5000 and New York +1 212 582
2333.
***********************************************************************************
--
u2-users mailing
list
[EMAIL PROTECTED]
http://www.oliver.com/mailman/listinfo/u2-users