Figured that one out after upgrading an AP to AC gear and found out that one of the clients was upgraded to 6 without the unii code activated.  Saved a 90 mile truck roll.


On 11/29/2017 04:53 PM, Mike Hammett wrote:
Nice!



-----
Mike Hammett
Intelligent Computing Solutions <http://www.ics-il.com/>
<https://www.facebook.com/ICSIL><https://plus.google.com/+IntelligentComputingSolutionsDeKalb><https://www.linkedin.com/company/intelligent-computing-solutions><https://twitter.com/ICSIL>
Midwest Internet Exchange <http://www.midwest-ix.com/>
<https://www.facebook.com/mdwestix><https://www.linkedin.com/company/midwest-internet-exchange><https://twitter.com/mdwestix>
The Brothers WISP <http://www.thebrotherswisp.com/>
<https://www.facebook.com/thebrotherswisp><https://www.youtube.com/channel/UCXSdfxQv7SpoRQYNyLwntZg>
------------------------------------------------------------------------
*From: *"Sam Tetherow" <[email protected]>
*To: *"ubnt users" <[email protected]>
*Sent: *Wednesday, November 29, 2017 4:40:55 PM
*Subject: *Re: [Ubnt_users] Radios won't operate on the same channel

ssh into the radio and

ubntbox dfs-unlock -u "YOUR COMPANY NAME" YOUR_ACTIVATION_CODE


On 11/29/2017 01:07 PM, Roy wrote:



    I have several codes but there is no "Activate" button. At the
    suggestion of another member of the mailing list, I regressed the
    Nanobridge to 5.6.9 and then the "Activate" button appeared.  I
    did than and then reinstalled 6.1.3. Luckily I had a copy of 5.6.9
    in my library

    To save anyone the digging to find out how to regress, I think
    these are the steps I used.

    1) install 6.0.6
    2) Install 6.0.6 beta
    3) reboot
    4) install 5.6.9

    Roy



    On 11/28/2017 9:55 PM, Mimbres Communications wrote:

        Do you have an unlock code for the NBM5?

        On Tue, Nov 28, 2017 at 9:50 PM, Roy <[email protected]
        <mailto:[email protected]>> wrote:


            I have a Nanobridge running 6.1.3 trying to connect to a
            Nanostation
            also running 6.1.3

            The Nanostation is the AP and set for 5630 Mhz.  The
            Nanobridge won't
            connect since it doesn't seem to allow operation on that
            channel?

            A check of allowed channels has the Nanobridge missing
            5585 to 5655 Mhz

            Any ideas on how to fix this?

            Roy
            _______________________________________________
            Ubnt_users mailing list
            [email protected] <mailto:[email protected]>
            http://lists.wispa.org/mailman/listinfo/ubnt_users




--
        Kurt Albershardt  |  Mimbres Communications, LLC  |  575-342-0042



        _______________________________________________
        Ubnt_users mailing list
        [email protected]
        http://lists.wispa.org/mailman/listinfo/ubnt_users




    _______________________________________________
    Ubnt_users mailing list
    [email protected]
    http://lists.wispa.org/mailman/listinfo/ubnt_users



_______________________________________________
Ubnt_users mailing list
[email protected]
http://lists.wispa.org/mailman/listinfo/ubnt_users



_______________________________________________
Ubnt_users mailing list
[email protected]
http://lists.wispa.org/mailman/listinfo/ubnt_users

_______________________________________________
Ubnt_users mailing list
[email protected]
http://lists.wispa.org/mailman/listinfo/ubnt_users

Reply via email to