Have a client that is difficult to login to at times, service for them 
seems to quit.  Has good signal strength.  Have changed the radio to 
different models and frequencies and connected to different towers.  
It's like some kind of barrier at random times is erected between house 
and tower.  Site survey and spectrum analyzer never show anything 
remotely definitive as to possible cause or source of trouble.  Could 
problem be noisy electrical transformers or well pumps and what low-cost 
equipment  would I need to find it?

-- 