On Tue, 28 Apr 2020 at 10:14, Giles Coochey <[email protected]> wrote:

>
> On 28/04/2020 09:49, Tom Bird wrote:
>
> On 27/04/2020 23:43, Marek Isalski wrote:
>
> Good luck to the engineers at 5089, 6830, and beyond.  Judging from status
> pages extending the outage to 06:00, it sounds like they're expecting to be
> in for a long night.
>
>
> The backup link for my house is a GRE tunnel over a cable modem so I've
> got some reasonably accurate times for the faults.
>
> Our  path (from Sheffield) into VM's network is via Level3 in Manchester,
> the return path always seems to be via London despite my best efforts to
> jog it so that doesn't happen.
>
> I've removed some of the verbosity from these log lines as only the
> timestamp and the up/down status are what we care about:
>
> <snip>
> BGP timers 30/90.
>
> It's going to be some weird telco nonsense isn't it.
>
> Previous attempt didn't like my inline image, data over VMB Line / GRE
> from Devon to London
>
> Event Start Time Event End Time Event Duration Event/State Type
> <snip>
>

 We now have a total outage on our VM circuit. Just checking if anyone is
in the same boat currently?

Attempting to failover to our BT backup circuit fails, understandably as
the requires route changes.

Thanks,
Simon.

Reply via email to