I just got my Hydro-flame running ,I had given up on it and was about to buy
a later model ,which would`nt have fit in same space, but soaked the burner
assembly in pb blaster, sandblasted ,and cleaned the orafice with a welding
tip cleaner . It doesnt blow out , its windy today and running , It doesnt
seem to regulate by the thermostatic thing ,(the bigger themocouple in back)
but runs steady with a powerfull flame , maybe your orafice is plugged up a
little ,or is it turning off because of thermostat ? So dont give up on it
yet - or send me the parts if you do ! 8>)
Chris 67 caravel Real nice picture you sent , looks fun !
----- Original Message -----
From: "C. Petrich" <[EMAIL PROTECTED]>
> We took out our '66 Caravel >
.. not as warm as we expected ->
> the HydroFlame heater keeps blowing out. The pilot light seems strong and
> blue, and the burner flame seems relatively strong (blue flame), but it
> doesn't stay lit. There was a breeze, but not a huge wind. Is this
normal
> for such a heater, and, if not, what is done to keep it lit?
>
>
To unsubscribe or to change to a daily Digest, please go to