Jed,
AA ,I have maintained from the beginning it was too early to tell the performance of the plant until more FACTS were available
Jed  The facts are now available.
AA.  Oh Yes?  Where can I see Penon's report or a piping diagram?

AA  You were wrong about Vaughn not being emp;poyed by Cherokee.
Jed  I do not know why you are hung up on it, but I suggest you ignore it.
AA Because you said I made it up and I then showed you proof the IH had lied about it and you were wrong.

Jed Rossi and Penon stuffed their data tables with identical & impossible numbers, and they showed excess power on days when Rossi in his blog said the machine was turned off. AA How can one tell that without seeing Penon's report? Second hand info from Murray is not proof.

AA As I've said before only a diagram of the piping will allow an engineer to judge the lightly hood of problems. Jed Nonsense. Half full pipes are common. Anyone can tell a pipe is half full by watching the water fall from it, and by various other means. AA Watching the water fall from a pipe in a closed system? That's even weaker than the stains.

AA Why should I believe an electronics guy employed by IH over a qualified independent expert like Dr. Penon? Jed Because it physically impossible for a flow rate to be EXACTLY 36,000 kg a day for months; because the flow meter was obviously unsuited to the task and an idiotic choice; because the pipe was half-full; AA I don't know that without seeing Penon's report and a piping diagram. Why was the flow meter unsuitable when it has been shown to be accurate at those flow rates?