Ditto here. I would stay clear of modular IOS and run something
like the latest SXF monolithic-blob image.
Or phrased another way,
"I encourage my competitors to run the latest modular IOS."
;-)
Cheers,
Dale
--
Dale W. Carder - Network Engineer
University of Wisconsin - Madison / WiscNet
http://net.doit.wisc.edu/~dwcarder
On Oct 16, 2007, at 7:49 AM, Jonathan Yantis wrote:
Joe, I would recommend running non-modular 12.2(18)SXF9 or perhaps
SXF11. SXH
is brand new, as is the modular code, and there are bound to be
problems.
WiSMs have been well tested with SXF code, so unless you have a
reason to run
12.2(33)SXH, try downgrading and your problem will likely go away.
--
Jonathan Yantis
Network Engineer
MUSC OCIO-IS NST
On Mon, Oct 15, 2007 at 03:55:52PM -0400, Roth, Joe wrote:
We have two Catalyst 6500's running native IOS. Both have 3 WiSM
blades
installed in each. We are currently running modular IOS ver 12.2
(33)SXH.
Both Sup720's seem to be leaking memory at a constant rate, about 7
megabytes a day. The Sup's eventually hit a point where telnet to it
becomes sluggish and the memory spikes frequently, then they reboot
themselves.
I am working with TAC, they seem the think that it is the udp.proc
process. I hate to point my finger at the WiSM blades, but I can't
think
of anything else that has changed within the last 6 months.
Has anyone else noticed similar issues?
**********
Participation and subscription information for this EDUCAUSE Constituent Group