Mike,

don't do that, the whole point of that query is to find out if the rig can be queried for the current VFO, the result determines how the rig is handled via the Hamlib API. Hamlib should return "not implemented", why is an "invalid parameter" error being returned?

73
Bill
G4WJS.

On 02/06/2020 23:21, Black Michael via wsjt-devel wrote:
So WSJT_X is asking "v" when the rig has no get_vfo function.

I could modify rig.c to return RIG_OK from rig_get_vfo if RIG_VFO_CURR is asked for.

Bill?

Mike W9MDB




On Tuesday, June 2, 2020, 04:03:30 PM CDT, DG2YCB, Uwe <[email protected]> wrote:


Hi Bill,

Done. See file enclosed. FYI: During the test, I clicked two times on the Test CAT button. Each times the error message popped up.

73 de Uwe, DG2YCB


_______________________________________________
wsjt-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/wsjt-devel

Reply via email to